Mechanical suppression of essential tremor
The DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
This paper describes a new treatment for essential tremor. A wearable orthosis, which can be adapted to each configuration of each joint of the upper limb, is able to apply effective dynamic force between consecutive segments of the upper limb and change its biomechanical characteristics. The orthosis is controlled by a computer with a dedicated software application that distinguishes between real time tremor and voluntary movement. The wearable orthosis is able to detect position, rate and acceleration of rotation of the joint by means of a chip gyroscope. This technology was evaluated in six patients suffering from essential tremor. The technique is non invasive and represents an alternative to medication and deep brain stimulation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore, nearly a quarter of the affected individuals do not respond to traditional treatments [15].”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [15]
In the citing paper
“Tremor suppression orthoses also have been investigated10-12, which function by physically forcing a person's tremor to cease13.”
From A noninvasive handheld assistive device to accommodate essential tremor: A pilot study (2014) · cites this paper as [11]
In the citing paper
“Quantification of tremor can be achieved using a wearable orthosis affixed on one upper limb [2].”
From Neurological Tremor: Sensors, Signal Processing and Emerging Applications (2010) · cites this paper as [2]
Citations
The citation lists are queued
They are fetched later and appear here then.
References 29 · Cited by 68
Research works printed but not linked: 4
- Riviere CN. Adaptive suppression of tremor for improved human-machine control. PhD dissertation, Johns Hopkins University, 1981.
- Michaelis J. Introducing the neater eater. Action Res. 1988;6:2–3.
- Hendriks J. A second-generation joystick for people disable by tremor. In: Proceedings of the 14th Annual RESNA Conference. Elmsford: NY, Ed, RESNA Press, 1991. pp 248–51.
- Belda-Lois JM, Vivas MJ, Castillo A, Peydro F, Garrido JD, Sanchez-Lacuesta J, Barberá R, Poveda R, Prat J. Functional assessment of tremor in the upper-limb. In: Proceedings of the 8th Congress of European Federation for Research in Rehabilitation, Ljubljana, Slovenia, 2004.
Metadata
- Authors
- Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M.
- Affiliations
- Erasmus Hospital (BE)
- ORCID
- Manto, Mario
- Venue
- The Cerebellum
- Published
- 2007-03
- Volume
- 6
- Issue
- 1
- Pages
- 73-8
- ISSN
- 1473-4222 (ISSN-L)
- 1473-4230
- OpenAlex
- W1964575743
- Cited by
- 68
- References
- 29
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 3 · 2022: 4 · 2021: 4 · 2020: 4 · 2019: 6 · 2018: 3 · 2017: 4 · 2016: 4 · 2015: 1 · 2014: 6 · 2013: 4 · 2012: 1
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- The Cerebellum (publishedVersion)
- PubMed (publishedVersion)
- Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) (submittedVersion)
- Funders
- Universitatea "Lucian Blaga" din Sibiu
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- essential tremor, wearable orthosis, upper limb biomechanics, tremor detection, non-invasive treatment
- MeSH terms
- Aged, Biomechanical Phenomena, Female, Humans, Male, Orthotic Devices, Physical Stimulation, Robotics, Essential Tremor, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical suppression of essential tremor. https://app.cochat.ai/papers/10.1080/14734220601103037
- The paper
- Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M. (2007). Mechanical suppression of essential tremor. The Cerebellum. https://doi.org/10.1080/14734220601103037
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.