The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fault diagnosis of photovoltaic modules through image processing and Canny edge detection on field thermographic measurements
Abstract
Today, conventional condition monitoring of installed, operating photovoltaic (PV) modules is mainly based on electrical measurements and performance evaluation. However, such practices exhibit restricted fault-detection ability. This study proposes the use of standard thermal image processing and the Canny edge detection operator as diagnostic tools for module-related faults that lead to hot-spot heating effects. The intended techniques were applied on thermal images of defective PV modules, from several field infrared thermographic measurements conducted during this study. The whole approach provided promising results with the detection of hot-spot formations that were diagnosed to specific defective cells in each inspected module. These evolving hot spots lead to abnormally low performance of the PV modules, a fact that is also validated by the manufacturer's standard electrical tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Research works printed but not linked: 23
- 10.1016/j.ndteint.2007.12.003 · doi:10.1016/j.ndteint.2007.12.003
- 10.1109/MCG.2007.323435 · DOI · Paper page
- 10.1088/0957-0233/18/3/038 · doi:10.1088/0957-0233/18/3/038
- Designation ASTM E2481-08. 2008. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules . ICS Number Code 27.160 (Solar energy engineering). doi:10.1520/E2481-08. · doi:10.1520/e2481-08
- 10.1063/1.1978979 · DOI
- 10.3166/qirt.4.85-105 · doi:10.3166/qirt.4.85-105
- Hardy, G. 1997. “Thermal Inspection.” Chap. 22 in ASM Handbook – Nondestructive Evaluation and Quality Control . Vol. 17, 5th ed. Materials Park, OH: ASM International.
- 10.1016/j.ndteint.2009.06.008 · doi:10.1016/j.ndteint.2009.06.008
- 10.1016/j.infrared.2004.03.011 · DOI
- 10.1063/1.2399346 · doi:10.1063/1.2399346
- 10.1016/j.microrel.2011.03.037 · doi:10.1016/j.microrel.2011.03.037
- 10.1016/j.solener.2006.11.014 · doi:10.1016/j.solener.2006.11.014
- 10.1002/0470014008 · DOI · Paper page
- Maldague, X. P. V. 2001. “Getting Started with Thermography for Nondestructive Testing”. Chap. 1 in Theory and Practice of Infrared Technology for Nondestructive Testing . 1st ed. New York: Wiley-Interscience.
- 10.1109/TSMC.1979.4310076 · DOI · Paper page
- 10.3390/s8085055 · doi:10.3390/s8085055
- 10.1016/j.solmat.2009.09.016 · doi:10.1016/j.solmat.2009.09.016
- 10.1016/j.solmat.2008.05.016 · doi:10.1016/j.solmat.2008.05.016
- 10.1115/1.4003731 · doi:10.1115/1.4003731
- 10.1109/TIE.2011.2163286 · doi:10.1109/tie.2011.2163286
- 10.1002/9783527630868 · DOI · Paper page
- 10.1080/09349847.2011.556543 · DOI
- Zayicek P., 2002, Infrared Thermography Guide
Cited by
Deep Metallic Surface Defect Detection: The New Benchmark and Detection Network
Lv, X., Duan, F., Jiang, J.-J., Fu, X., & Gan, L. (2020) · Sensors · doi:10.3390/s20061562 · Cited by 643
“In detail, the commonly used structural-based methods include skeleton-based [8], template match [9], edge-based [10], and morphological operations [11].”
MethodAutomatic Metallic Surface Defect Detection and Recognition with Convolutional Neural Networks
Tao, X., Zhang, D., Ma, W., Liu, X., & Xu, D. (2018) · Applied Sciences · doi:10.3390/app8091575 · Cited by 471
“The structural method includes edge [12], skeleton [13], template match [14], and morphological operations [15].”
MethodLi, W., Zhang, H., Wang, G., Xiong, G., Zhao, M., Li, G., & Li, R. (2023) · Robotics and Computer-Integrated Manufacturing · doi:10.1016/j.rcim.2022.102470 · Cited by 266
Metadata
- Authors
- Tsanakas, J. A., Chrysostomou, D., Botsaris, P. N., & Gasteratos, A.
- Venue
- International Journal of Sustainable Energy
- Publisher
- Informa UK Limited
- Published
- 2013-08-14
- Volume
- 34
- Issue
- 6
- Pages
- 351-372
- ISSN
- 0142-5919 (ISSN-L)
- 1478-6451
- 1478-646X
- OpenAlex
- W2157597705
- Cited by
- 202
- References
- 1
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault diagnosis of photovoltaic modules through image processing and Canny edge detection on field thermographic measurements. https://app.cochat.ai/papers/10.1080/14786451.2013.826223
- The paper
- Tsanakas, J. A., Chrysostomou, D., Botsaris, P. N., & Gasteratos, A. (2015). Fault diagnosis of photovoltaic modules through image processing and Canny edge detection on field thermographic measurements. International Journal of Sustainable Energy. https://doi.org/10.1080/14786451.2013.826223
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.