The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Development and validation of an automatic speech-in-noise screening test by telephone
Abstract
To meet the need for an objective self-test for hearing screening. a new Dutch speech-in-noise test was developed. Digit triplets were used as speech material. The test was made fully automatic, was controlled by a computer, and can be done by telephone. It measures the speech reception threshold (triplet SRT(n)) using an adaptive procedure, in about 3 min. Our experiments showed no significant influence of telephone type or listening environment. Measurement errors were within 1 dB. which makes the test accurate. In additional experiments with hearing-impaired subjects (76 ears of 38 listeners), the new test was compared to the existing sentence SRT(n) test of Plomp and Mimpen, which is considered to be the standard. The correlation between both SRT(n)s was 0.866. As expected, correlations between the triplet SRT(n) test by telephone and average pure-tone thresholds are somewhat lower: 0.732 for PTA(0,5,1,2), and 0.770 for PTA(0,5,2,4). When proper SRT(n) values were chosen for distinguishing between normal-hearing and hearing-impaired subjects, the triplet SRT(n) test was found to have a sensitivity of 0.91 and a specificity of 0.93.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nilsson, M., Soli, S. D., & Sullivan, J. A. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.408469 · Cited by 2,078
Festen, J. M., & Plomp, R. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.400247 · Cited by 856
The intelligibility of speech as a function of the context of the test materials.
Miller, G. A., Heise, G. A., & Lichten, W. (1951) · Journal of Experimental Psychology · doi:10.1037/h0062491 · Cited by 769
Improving the Reliability of Testing the Speech Reception Threshold for Sentences
Plomp, R., & Mimpen, A. M. (1979) · International Journal of Audiology · doi:10.3109/00206097909072618 · Cited by 722
Sentences for Testing Speech Intelligibility in Noise
Hagerman, B. (1982) · Scandinavian Audiology · doi:10.3109/01050398209076203 · Cited by 440
Versfeld, N. J., Daalder, L., Festen, J. M., & Houtgast, T. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.428451 · Cited by 341
Self-citationSpeech-reception threshold for sentences as a function of age and noise level
Plomp, R., & Mimpen, A. M. (1979) · The Journal of the Acoustical Society of America · doi:10.1121/1.383554 · Cited by 324
Kollmeier, B., & Wesselkamp, M. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.419624 · Cited by 286
Smoorenburg, G. F. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.402729 · Cited by 267
Statistical Methods in Laboratory Medicine
(1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-116-8-704_3 · Cited by 119
Cited by
Hearing Loss and Cognition: The Role of Hearing Aids, Social Isolation and Depression
Dawes, P., Emsley, R., Cruickshanks, K. J., Moore, D. R., Fortnum, H., Edmondson-Jones, M., McCormack, A., & Munro, K. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0119616 · Cited by 520
Objectives, design and main findings until 2020 from the Rotterdam Study
Ikram, M. A., Brusselle, G., Ghanbari, M., Goedegebure, A., Ikram, M. K., Kavousi, M., Kieboom, B. C. T., Klaver, C. C. W., de Knegt, R. J., Luik, A. I., et al. (2020) · European Journal of Epidemiology · doi:10.1007/s10654-020-00640-5 · Cited by 452
The Rotterdam Study: 2018 update on objectives, design and main results
Ikram, M. A., Brusselle, G. G. O., Murad, S. D., van Duijn, C. M., Franco, O. H., Goedegebure, A., Klaver, C. C. W., Nijsten, T. E. C., Peeters, R. P., Stricker, B. H., et al. (2017) · European Journal of Epidemiology · doi:10.1007/s10654-017-0321-4 · Cited by 434
The Rotterdam Study: 2016 objectives and design update
Hofman, A., Brusselle, G. G. O., Murad, S. D., van Duijn, C. M., Franco, O. H., Goedegebure, A., Ikram, M. A., Klaver, C. C. W., Nijsten, T. E. C., Peeters, R. P., et al. (2015) · European Journal of Epidemiology · doi:10.1007/s10654-015-0082-x · Cited by 382
Tinnitus affects speech in noise comprehension in individuals with hearing loss.
Oosterloo, B. C., Homans, N. C., & Goedegebure, A. (2020) · Otology & Neurotology · doi:10.1097/mao.0000000000002733 · Cited by 14
Metadata
- Authors
- Smits, C., Kapteyn, T. S., & Houtgast, T.
- Venue
- International Journal of Audiology
- Publisher
- Informa UK Limited
- Published
- 2004-01
- Volume
- 43
- Issue
- 1
- Pages
- 15-28
- ISSN
- 1499-2027 (ISSN-L)
- 1708-8186
- OpenAlex
- W2051951610
- Cited by
- 423
- References
- 12
- FWCI
- 1.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and validation of an automatic speech-in-noise screening test by telephone. https://app.cochat.ai/papers/10.1080/14992020400050004
- The paper
- Smits, C., Kapteyn, T. S., & Houtgast, T. (2004). Development and validation of an automatic speech-in-noise screening test by telephone. International Journal of Audiology. https://doi.org/10.1080/14992020400050004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.