The DOI matches its Crossref record.
Tinnitus and cochlear implantation
Abstract
Tinnitus is a common experience, but there is very marked heterogeneity of aetiology, perception and the extent of distress among individuals who experience tinnitus. In view of this, a modern approach to tinnitus should consider homogeneous groups of individuals. This review considers tinnitus experiences in patients undergoing cochlear implantation, this being of interest because the prevalence of tinnitus in this patient group prior to surgery may shed some light on the link between cochlear dysfunction and tinnitus Second, any change in tinnitus experience as a result of electrode placement surgery or cochlear implant activation has relevance for patient counselling and informed consent. Finally, in recent tinnitus retraining therapy literature there has been the suggestion that unilateral sound therapy for tinnitus patients may set up an unhelpful asymmetry of input to the auditory system, with possible exacerbation of contralateral tinnitus. Unilateral cochlear implant use represents the most dramatic asymmetry possible and hence is a test of that hypothesis. Relevant papers (n = 32) were identified from literature databases. The standard of reporting tinnitus results was inconsistent. Tinnitus is experienced by up to 86% of adult cochlear implant candidates, but is not universal and is only troublesome in a small proportion (reported as 27% in one study). Electrode insertion may induce tinnitus in a small (up to 4%) number of patients, but this is rare. Cochlear implant device use is associated with reduction of tinnitus intensity and awareness in up to 86% of patients, and rarely with exacerbation (up to 9%). There are some indications in the literature that the more complex the simulation strategy, the larger that effect. Specifically, unilateral cochlear implant use was generally associated with reduction of contralateral tinnitus (in up to 67% of individuals) rather than exacerbation, and so the assertion that unilateral sound therapy for tinnitus is contraindicated is not proven.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An integrative model of tinnitus based on a central gain controlling neural sensitivity
Noreña, A. J. (2011) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2010.11.003 · Cited by 452
A multidisciplinary European guideline for tinnitus: diagnostics, assessment, and treatment
Cima, R. F. F., Mazurek, B., Haider, H., Kikidis, D., Lapira, A., Noreña, A., & Hoare, D. J. (2019) · HNO · doi:10.1007/s00106-019-0633-7 · Cited by 442
Schaette, R., & Kempter, R. (2006) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2006.04774.x · Cited by 315
Cochlear Implants as a Treatment Option for Unilateral Hearing Loss, Severe Tinnitus and Hyperacusis
Ramos Macías, A., Falcón González, J. C., Manrique, M., Morera, C., García-Ibáñez, L., Cenjor, C., Coudert-Koall, C., & Killian, M. (2015) · Audiology and Neurotology · doi:10.1159/000380750 · Cited by 46
Metadata
- Authors
- Quaranta, N., Wagstaff, S., & Baguley, D. M.
- Venue
- International Journal of Audiology
- Publisher
- Informa UK Limited
- Published
- 2004-01
- Volume
- 43
- Issue
- 5
- Pages
- 245-251
- ISSN
- 1499-2027 (ISSN-L)
- 1708-8186
- OpenAlex
- W1966753701
- Cited by
- 161
- References
- 0
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tinnitus and cochlear implantation. https://app.cochat.ai/papers/10.1080/14992020400050033
- The paper
- Quaranta, N., Wagstaff, S., & Baguley, D. M. (2004). Tinnitus and cochlear implantation. International Journal of Audiology. https://doi.org/10.1080/14992020400050033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.