Cochlear Implants as a Treatment Option for Unilateral Hearing Loss, Severe Tinnitus and Hyperacusis
Open accessThe DOI matches its Crossref record; 53 of the 54 references it cites were found in a registry or an index.
Abstract
Tinnitus is an incapacitating condition commonly affecting cochlear implant (CI) candidates. The aim of this clinical study is to assess the long-term effects of CI treatment in patients with severe-to-profound, sensorineural, unilateral hearing loss (UHL) and incapacitating tinnitus. We performed a prospective Cochlear™ company-sponsored multicentre study in five Spanish centres. Sixteen patients with UHL and incapacitating tinnitus, which was indicated by a Tinnitus Handicap Inventory (THI) score >58%, received a Nucleus® CI in their deaf ear. The study design includes repeated within-subject measures on hearing, tinnitus, hyperacusis and quality of life up to 12 months after initial CI fitting. In addition to hearing loss and tinnitus, all patients suffered from hyperacusis. Most patients had a sudden hearing loss and received a CI within 2 years after their hearing loss. Preliminary 6-month, post-CI activation data of 13 subjects showed that the majority of patients perceived a subjective benefit from CI treatment, which was assessed using the THI, a Visual Analogue Scale of tinnitus loudness/annoyance and the Speech, Spatial and Qualities of Hearing Scale. Preliminary 12-month data of 7 subjects showed that most patients also perceived a degree of relief from their hyperacusis. One patient showed no improvements in any of the applied scales, which could be explained by partial insertion of the electrode due to obstruction of the cochlea by otosclerosis. In conclusion, CI can successfully be used in the treatment of UHL patients with accompanying severe tinnitus and hyperacusis. Implantation resulted in hearing benefits and a durable relief from tinnitus and hyperacusis in the majority of patients. These findings support the hypothesis that pathophysiological mechanisms after peripheral sensorineural hearing loss are at least partly reversible when hearing is restored with a CI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Speech, Spatial and Qualities of Hearing Scale (SSQ)
Gatehouse, S., & Noble, W. (2004) · International Journal of Audiology · doi:10.1080/14992020400050014 · Cited by 1,385
Uses and abuses of hearing loss classification.
Clark, J. (1981) · PubMed · Cited by 860
Tinnitus: causes and clinical management
Langguth, B., Kreuzer, P. M., Kleinjung, T., & De Ridder, D. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70160-1 · Cited by 799
Tinnitus—a study of its prevalence and characteristics
Axelsson, A., & Ringdahl, A. (1989) · British Journal of Audiology · doi:10.3109/03005368909077819 · Cited by 749 · cited 1×
“, 2013] and occurs in about 35% of the general population [McFadden, 1982; Axelsson and Ringdahl, 1989] and 85% of patients with hearing disorders [Coles, 1987], and the pathomechanisms underlying tinnitus and hyperacusis have often been ascribed a peripheral origin [Knipper et al.”
BackgroundArndt, S., Aschendorff, A., Laszig, R., Beck, R., Schild, C., Kroeger, S., Ihorst, G., & Wesarg, T. (2011) · Otology & Neurotology · doi:10.1097/mao.0b013e3181fcf271 · Cited by 514 · cited 4×
“Recent studies have shown that a CI can effectively restore binaural hearing in patients with severe-to-profound, sensorineural, unilateral hearing loss (UHL) and helps these patients to find a relief of their concomitant tinnitus [Van den Heyning et al., 2008; Kleinjung et al., 2009; Buechner et al., 2010; Carlyon et…”
BackgroundInfluentialPsychometric adequacy of the Tinnitus Handicap Inventory (THI) for evaluating treatment outcome.
Newman, C. W., Sandridge, S. A., & Jacobson, G. P. (1998) · PubMed · Cited by 474
McCombe, A., Baguley, D., Coles, R., McKenna, L., McKinney, C., & Windle-Taylor, P. (2001) · Clinical Otolaryngology and Allied Sciences · doi:10.1046/j.1365-2273.2001.00490.x · Cited by 424 · cited 1×
“Tinnitus burden is assessed with the Spanish version of the THI [Newman et al., 1998; Herráiz et al., 2001; McCombe et al., 2001] with handicap categories for the THI score being: no handicap 0–16% (grade 1), mild handicap 18–36% (grade 2), moderate handicap 38–56% (grade 3) and severe handicap…”
MethodIncapacitating Unilateral Tinnitus in Single-Sided Deafness Treated by Cochlear Implantation
Van de Heyning, P., Vermeire, K., Diebl, M., Nopp, P., Anderson, I., & De Ridder, D. (2008) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940811700903 · Cited by 413
Noreña, A. J., & Eggermont, J. J. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2226-04.2005 · Cited by 337 · cited 2×
“Hearing restauration with CI is best with multichannel intracochlear electrode arrays, and concomitant tinnitus-suppressive effects can be explained by masking effects and plastic changes in the auditory system caused by enrichment of the peripheral auditory input [Noreña and Eggermont, 2005; Eggermont, 2015].”
BackgroundVermeire, K., & Van de Heyning, P. (2009) · Audiology and Neurotology · doi:10.1159/000171478 · Cited by 337
Cited by
The psychological and social consequences of single-sided deafness in adulthood
Lucas, L., Katiri, R., & Kitterick, P. T. (2017) · International Journal of Audiology · doi:10.1080/14992027.2017.1398420 · Cited by 121
“Cochlear implantation has also been associated with benefits to hearingspecific quality of life, with the additional benefit of reduced difficulty with identifying the location of sound sources, navigating everyday environments and tinnitus relief (Arndt et al. 2011; Arndt, Laszig, and Aschendorff 2017; Finke et al. 2…”
BackgroundEspinosa-Sánchez, J. M., & Lopez-Escamez, J. A. (2016) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63437-5.00019-4 · Cited by 123
Mertens, G., De Bodt, M., & Van de Heyning, P. (2016) · Hearing Research · doi:10.1016/j.heares.2015.09.016 · Cited by 103
Peter, N., Liyanage, N., Pfiffner, F., Huber, A. M., & Kleinjung, T. (2019) · Otolaryngology · doi:10.1177/0194599819846084 · Cited by 93
“When the SSD population was separately listed in the publications, only this subgroup contributed to the further analysis.(34) In some studies, the AHL and SSD groups could not be separated, which led to a rating of unsatisfactory in the patient section of directness of evidence.”
BackgroundMethodResultInfluentialFackrell, K., Potgieter, I., Shekhawat, G. S., Baguley, D. M., Sereda, M., & Hoare, D. J. (2017) · BioMed Research International · doi:10.1155/2017/2723715 · Cited by 93
“Of the included records, 23 were case studies [19, 25–27, 34–38, 40–43, 49–58], seven were cohort studies [28, 29, 39, 44, 46, 59, 60], five were RCTs [18, 20, 21, 30, 47], four were Nonrandomised Controlled Trials [22, 23, 31, 48], and four were retrospective studies [24, 32, 33, 45].”
BackgroundInfluential
Metadata
- Authors
- Ramos Macías, A., Falcón González, J. C., Manrique, M., Morera, C., García-Ibáñez, L., Cenjor, C., Coudert-Koall, C., & Killian, M.
- Affiliations
- Clinica Universidad de Navarra (ES)
- Hospital Universitari i Politècnic La Fe (ES)
- Cochlear (Switzerland) (CH)
- Venue
- Audiology and Neurotology
- Publisher
- S. Karger AG
- Published
- 2015
- Volume
- 20
- Issue
- Suppl. 1
- Pages
- 60-66
- ISSN
- 1420-3030 (ISSN-L)
- 1421-9700
- OpenAlex
- W1499833060
- Cited by
- 46
- References
- 54
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 4 · 2020: 8 · 2019: 3 · 2018: 3 · 2017: 6 · 2016: 5 · 2015: 2
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- creativecommons.org/licenses/by-nc/3.0/ (vor)
- creativecommons.org/licenses/by-nc/3.0/ (tdm)
- Locations
- Audiology and Neurotology (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
- Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
- Social Sciences › Psychology › Developmental and Educational Psychology › Hearing Impairment and Communication
- Keywords
- cochlear implants, unilateral hearing loss, tinnitus, hyperacusis, sensorineural hearing loss, sudden sensorineural hearing loss, tinnitus handicap, quality of life, otosclerosis, hearing restoration
- MeSH terms
- Adult, Aged, Cochlear Implants, Hearing Loss, Sudden, Female, Hearing Loss, Sensorineural, Humans, Male, Middle Aged, Prospective Studies, Quality of Life, Hyperacusis, Severity of Illness Index, Tinnitus, Treatment Outcome, Cochlear Implantation, Hearing Loss, Unilateral
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cochlear Implants as a Treatment Option for Unilateral Hearing Loss, Severe Tinnitus and Hyperacusis. https://app.cochat.ai/papers/10.1159/000380750
- The paper
- Ramos Macías, A., Falcón González, J. C., Manrique, M., Morera, C., García-Ibáñez, L., Cenjor, C., Coudert-Koall, C., & Killian, M. (2015). Cochlear Implants as a Treatment Option for Unilateral Hearing Loss, Severe Tinnitus and Hyperacusis. Audiology and Neurotology. https://doi.org/10.1159/000380750
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.