The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index; none of the 6 sources its claims cite is checked for support yet.
Dissociable effects of hyperacusis and misophonia severity imply different mechanisms of decreased sound tolerance
Open accessAbstract
OBJECTIVE: It is thought that decreased sound tolerance can be subdivided into distinct types including misophonia (involving specific trigger sounds) and hyperacusis (broader in profile). However, there are few established methods for differentially assessing these disorders and this is complicated by the fact that some measures (e.g. the HQ Hyperacusis Questionnaire) were developed before the concept of misophonia was accepted. DESIGN/STUDY SAMPLE: = 119 participants with misophonia (varying in severity) and asked them about the presence of hyperacusis (based on a scoping review definition). RESULTS: Scores for some items on the HQ were correlated with scores for misophonia severity (e.g. social impact of sound) and others with scores for hyperacusis (e.g. ability to concentrate in noise). Similarly, some trigger sounds were more indicative of hyperacusis (e.g. dishes being stacked) and others were more indicative of misophonia in the absence of hyperacusis (e.g. chewing). CONCLUSIONS: These double dissociations provide compelling evidence for separable forms of sound intolerance. Moreover, our research suggests that a single-item question about hyperacusis is associated with other characteristics of hyperacusis, even when assessed 18 months later.
Overview
CoChat Summary
TL;DR
In 119 adults with self-identified misophonia, item-level analyses showed double dissociations: some Hyperacusis Questionnaire items and trigger sounds tracked hyperacusis, while others tracked misophonia. These dissociations support separable mechanisms of decreased sound tolerance, even though total HQ scores correlated with both constructs.
Key findings
- The sample comprised 119 adults aged 18–70 (mean age = 44.8, SD = 14.3; 79.0% female, 18.5% male, 2.5% non-binary), all self-identified as having misophonia. SMS total scores had mean = 83.7, SD = 23.1, range = 37–139; 47% (66/119) endorsed the hyperacusis screener.
- Mean HQ total was 24.3 (± 7.2) versus published population norms of 15.0 (± 6.7), t = 11.67, p < .001, Hedge’s g = 1.35. Using Khalfa et al.’s threshold (>28), 30% (36/119) would be classified as having hyperacusis; using Meeus et al.’s threshold (>26), 39.5% (47/119). HQ total correlated with SMS total (r = 0.49, p < .001) and with the hyperacusis screener (r = 0.41, p < .001); the screener and SMS total correlated weakly and non-significantly (r = 0.13, p = .177).
- At the HQ item level, 3 items correlated significantly more with hyperacusis than misophonia (H≫M), 5 correlated significantly more with misophonia than hyperacusis (M≫H), 2 correlated with hyperacusis but not misophonia without a significant difference (H>M), and 4 could not discriminate the constructs. Most significant differences survived FDR correction except HQ3. Hyperacusis items related more to sound-based distraction/background noise; misophonia items related more to social impacts of sound.
- Trigger sounds showed a double dissociation: 5 triggers were more endorsed by those with misophonia plus hyperacusis (house and car alarms, car engines, repetitive barking, typing, sirens), while 3 were more endorsed by those with misophonia without hyperacusis (lip smacking, swallowing, chewing). For CORDS sounds, 13/20 significantly distinguished groups, all with greater endorsement by those reporting hyperacusis. Those with hyperacusis were less likely to have attended many loud concerts (χ²(1) = 5.73, p = .017) and more likely to report sensitive teeth (χ²(1) = 7.08, p = .008). Pain was linked to both constructs; the association between misophonia severity and 12-month pain remained significant (r = 0.21, p = .021) after dropping four SMS pain items.
Methods
- Participants were 119 adults with self-identified misophonia, recruited from a previous study following a BBC radio interview on 18 May 2021. They completed the Sussex Misophonia Scale (SMS) and a single-item hyperacusis screener initially; 18 months later they completed the HQ and CORDS hyperacusis items via Qualtrics (~30 minutes). No audiological assessment was performed, but participants had to indicate no known hearing loss.
- The SMS includes 48 specific trigger sounds and 39 Likert-type items (0–4, total 0–156; cut-off 50.5, AUC = 0.91). The hyperacusis screener was based on the Fackrell et al. scoping definition and used a four-point agreement scale. The HQ has 14 items on a four-point scale; CORDS items from Williams et al. (2021) were analysed separately because there was no known way to collapse them into factors or total scores.
- Analyses compared item-level correlations against SMS total and hyperacusis screener using the Steiger method, with chi-square tests for categorical trigger endorsement and FDR correction for multiple comparisons.
Limitations
- Stated in the paper: participants did not undergo audiological assessment; hearing loss was excluded only by requiring no known hearing loss. The hyperacusis “ground truth” was a single-item screener rather than a clinical diagnosis, and CORDS items had no established method for collapsing into factors or total scores.
- Evident from the text: all participants self-identified as having misophonia and were recruited via a BBC radio interview, with a predominantly female sample (79.0%), so findings may not generalise to the general population or to hyperacusis without misophonia. The 18-month lag between initial and later measures may also introduce change or attrition, though the authors frame the associations as reflecting enduring traits. The provided text is truncated before the end of the Discussion, so additional stated limitations may not be visible.
Model-written summary of a shortened version of the paper’s full text (it is longer than we read). Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 1 Not valid · 6 Not checked · 23 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“misophonics were more likely to report turning down social invitations because of the sounds (reported on the HQ)”
hedgedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Scores for some items on the HQ were correlated with scores for misophonia severity (e.g. social impact of sound) and others with scores for hyperacusis (e.g. ability to concentrate in noise).”
- Also stated in: § Discussion · plain
“Although the total score for the HQ was correlated with both our measure of hyperacusis and our measure of misophonia, at the item level, there were double dissociations, some items tracking misophonia severity and others tracking hyperacusis.”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Discussion · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The correlation between the HQ total and scores for the hyperacusis screener question was moderate and significant (r = 0.41, p < .001)”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Those with hyperacusis were significantly less likely to have attended many loud concerts (χ2(1) = 5.73, p = 0.017)”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Those with hyperacusis were significantly more likely to report sensitive teeth (χ2(1) = 7.08, p = 0.008).”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
12 more claims
Create a free account to see all 30 claims and every source verdict.
- It may state two separate claims as one. 9
- Probably not a substantial claim. 6
Statistics recomputed
Every reported test result, recomputed from its test statistic and degrees of freedom. A result shows as not adding up only once an independent check has confirmed it.
- Consistentχ²(1) = 5.73reported p = .017 · recomputed p = .017
“χ2(1) = 5.73, p = .017”
- Consistentχ²(1) = 7.08reported p = .008 · recomputed p = .008
“χ2(1) = 7.08, p = .008”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“For the hyperacusis screener (see below), 47% (66/119) of our sample reported that this applied to them”
Reported 47 · recomputed 55.462185
Citations
Cites
Tests for comparing elements of a correlation matrix
Steiger, J. H. (1980) · Psychological Bulletin · doi:10.1037/0033-2909.87.2.245 · Cited by 4,621 · cited 1×
“The method of Steiger (1980) was used to compare two correlations within the same sample of participants (r 12 and r 13 ) and considering the degree of relationship between the two measures (r 23 ).”
Psychometric Normalization of a Hyperacusis Questionnaire
Khalfa, S., Dubal, S., Veuillet, E., Perez-Diaz, F., Jouvent, R., & Collet, L. (2002) · ORL · doi:10.1159/000067570 · Cited by 488 · cited 5×
“The mean HQ total score for our misophonic group was 24.3 (± 7.2) which compares against published population norms of 15.0 (± 6.7) from Khalfa et al. (2002).”
InfluentialMisophonia: Incidence, Phenomenology, and Clinical Correlates in an Undergraduate Student Sample
Wu, M. S., Lewin, A. B., Murphy, T. K., & Storch, E. A. (2014) · Journal of Clinical Psychology · doi:10.1002/jclp.22098 · Cited by 360 · cited 1×
“Several questionnaires have been developed to diagnose misopho-nia (Rosenthal et al. 2021; Simner, Rinaldi, and Ward 2024; Wu et al. 2014).”
Consensus Definition of Misophonia: A Delphi Study
Swedo, S. E., Baguley, D. M., Denys, D., Dixon, L. J., Erfanian, M., Fioretti, A., Jastreboff, P. J., Kumar, S., Rosenthal, M. Z., Rouw, R., et al. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.841816 · Cited by 249 · cited 2×
“There has been significant recent interest in the idea that decreased sound tolerance can be subdivided into distinct types, such that the term hyperacusis has recently come to be restricted to one profile with a second profile (misophonia) alongside (Swedo et al. 2022).”
Self-citationDecreased Sound Tolerance and Tinnitus Retraining Therapy (TRT)
Jastreboff, M. M., & Jastreboff, P. J. (2002) · Australian and New Zealand Journal of Audiology · doi:10.1375/audi.24.2.74.31105 · Cited by 210 · cited 1×
“Notably, Jastreboff and Jastreboff (2002) proposed the term misophonia to denote decreased tolerance to specific trigger sounds, largely eating sounds such as chewing and repetitive sounds such as tapping.”
Audiometric Characteristics of Hyperacusis Patients
Sheldrake, J. B., Diehl, P. U., & Schaette, R. (2015) · Frontiers in Neurology · doi:10.3389/fneur.2015.00105 · Cited by 180 · cited 1×
“…of sounds can occur in the presence of other hearing abnormalities (such as tinnitus or hearing loss) but can also be found for some people in the general population with no other auditory abnormality (Baguley and Hoare 2018; Paulin, Andersson, and Nordin 2016; Sheldrake, Diehl, and Schaette 2015).”
Williams, Z. J., He, J. L., Cascio, C. J., & Woynaroski, T. G. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2020.11.030 · Cited by 175 · cited 3×
“The CORDS (Coordination of Rare Diseases at Sanford) hyperacusis questionnaire, reported by Williams et al. (2021), contains various items related to hyper-acusis and loud sound exposure.”
Discovering new treatments for sensitive teeth: the long path from biology to therapy
Markowitz, K., & Pashley, D. H. (2007) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2007.01798.x · Cited by 162
Characteristics of hyperacusis in the general population
Paulin, J., Andersson, L., & Nordin, S. (2016) · Noise and Health · doi:10.4103/1463-1741.189244 · Cited by 139 · cited 1×
“…of sounds can occur in the presence of other hearing abnormalities (such as tinnitus or hearing loss) but can also be found for some people in the general population with no other auditory abnormality (Baguley and Hoare 2018; Paulin, Andersson, and Nordin 2016; Sheldrake, Diehl, and Schaette 2015).”
Aazh, H., & Moore, B. C. J. (2017) · International Journal of Audiology · doi:10.1080/14992027.2017.1335888 · Cited by 129 · cited 1×
“Patients with hyperacusis typically report everyday sounds as feeling too loud, and when presented with pure tones, judge them to be uncomfortable at a lower loudness level than people without hyperacusis (Aazh and Moore 2017).”
Research works printed but not linked: 1
- 10.1002/jclp.22098 · DOI · Paper page
Cited by
Aazh, H., & Kula, F. B. (2024) · Brain Sciences · doi:10.3390/brainsci15010016 · Cited by 15
Aryal, S., Moskovich, A. A., Prabhu, P., & Rosenthal, M. Z. (2025) · Hearing Research · doi:10.1016/j.heares.2025.109457 · Cited by 4
Ward, J., Agbude, R., Smees, R., Simner, J., & Ronen, I. (2025) · Hearing Research · doi:10.1016/j.heares.2025.109440 · Cited by 3
Self-citationRinaldi, L. J., Karapanagiotidis, T., Koch, E. M. W., Sanderson, A., Strawson, W. H., Simner, J., Eccles, J., Critchley, H., Aazh, H., & Poerio, G. L. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-119037 · Cited by 1
Self-citationAttention and physiological responses to task-irrelevant sounds in misophonia
Rinaldi, L. J., Agbude, R., Andermane, N., Makowski, D., Forster, S., Simner, J., & Ward, J. (2026) · Journal of Clinical and Experimental Neuropsychology · doi:10.1080/13803395.2026.2633236
“…test shows “excellent” classification accuracy (Simner et al., 2024), and also has strong convergent validity, with scores being highly correlated (Smees et al., 2024) with those for the Misophonia Questionnaire (Wu et al., 2014), Duke-Vanderbilt Misophonia Screening Questionnaire (Williams et…”
Self-citation
Metadata
- Authors
- Smees, R., Simner, J., Hoare, D. J., & Ward, J.
- Affiliations
- University of Sussex (GB)
- University of Nottingham (GB)
- Corresponding author
- Ward, Jamie
- Venue
- International Journal of Audiology
- Publisher
- Informa UK Limited
- Published
- 2024-10-31
- Volume
- 64
- Issue
- 9
- Pages
- 964-971
- ISSN
- 1499-2027 (ISSN-L)
- 1708-8186
- OpenAlex
- W4403989428
- Cited by
- 7
- References
- 23
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 1
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- International Journal of Audiology (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion, other-oa)
- Figshare (submittedVersion, cc-by)
- Funders
- REAM Foundation
- National Institute for Health and Care Research
- Department of Health and Social Care
- NIHR Nottingham Biomedical Research Centre
- Topics
- Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
- Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
- Physical Sciences › Physics and Astronomy › Acoustics and Ultrasonics › Noise Effects and Management
- Keywords
- hyperacusis, misophonia, sound intolerance, sound tolerance, double dissociation
- MeSH terms
- Adolescent, Adult, Aged, Auditory Perception, Female, Hearing Disorders, Humans, Male, Middle Aged, Noise, Surveys and Questionnaires, Hyperacusis, Severity of Illness Index, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dissociable effects of hyperacusis and misophonia severity imply different mechanisms of decreased sound tolerance. https://app.cochat.ai/papers/10.1080/14992027.2024.2419558
- The paper
- Smees, R., Simner, J., Hoare, D. J., & Ward, J. (2025). Dissociable effects of hyperacusis and misophonia severity imply different mechanisms of decreased sound tolerance. International Journal of Audiology. https://doi.org/10.1080/14992027.2024.2419558
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.