Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index; none of the 6 sources its claims cite is checked for support yet.

Dissociable effects of hyperacusis and misophonia severity imply different mechanisms of decreased sound tolerance

Open access
Smees, Rebecca, Simner, Julia, Hoare, Derek J., Ward, Jamie · 2025 · International Journal of Audiology

Abstract

OBJECTIVE: It is thought that decreased sound tolerance can be subdivided into distinct types including misophonia (involving specific trigger sounds) and hyperacusis (broader in profile). However, there are few established methods for differentially assessing these disorders and this is complicated by the fact that some measures (e.g. the HQ Hyperacusis Questionnaire) were developed before the concept of misophonia was accepted. DESIGN/STUDY SAMPLE: = 119 participants with misophonia (varying in severity) and asked them about the presence of hyperacusis (based on a scoping review definition). RESULTS: Scores for some items on the HQ were correlated with scores for misophonia severity (e.g. social impact of sound) and others with scores for hyperacusis (e.g. ability to concentrate in noise). Similarly, some trigger sounds were more indicative of hyperacusis (e.g. dishes being stacked) and others were more indicative of misophonia in the absence of hyperacusis (e.g. chewing). CONCLUSIONS: These double dissociations provide compelling evidence for separable forms of sound intolerance. Moreover, our research suggests that a single-item question about hyperacusis is associated with other characteristics of hyperacusis, even when assessed 18 months later.

Overview

CoChat Summary

TL;DR

In 119 adults with self-identified misophonia, item-level analyses showed double dissociations: some Hyperacusis Questionnaire items and trigger sounds tracked hyperacusis, while others tracked misophonia. These dissociations support separable mechanisms of decreased sound tolerance, even though total HQ scores correlated with both constructs.

Key findings

  • The sample comprised 119 adults aged 18–70 (mean age = 44.8, SD = 14.3; 79.0% female, 18.5% male, 2.5% non-binary), all self-identified as having misophonia. SMS total scores had mean = 83.7, SD = 23.1, range = 37–139; 47% (66/119) endorsed the hyperacusis screener.
  • Mean HQ total was 24.3 (± 7.2) versus published population norms of 15.0 (± 6.7), t = 11.67, p < .001, Hedge’s g = 1.35. Using Khalfa et al.’s threshold (>28), 30% (36/119) would be classified as having hyperacusis; using Meeus et al.’s threshold (>26), 39.5% (47/119). HQ total correlated with SMS total (r = 0.49, p < .001) and with the hyperacusis screener (r = 0.41, p < .001); the screener and SMS total correlated weakly and non-significantly (r = 0.13, p = .177).
  • At the HQ item level, 3 items correlated significantly more with hyperacusis than misophonia (H≫M), 5 correlated significantly more with misophonia than hyperacusis (M≫H), 2 correlated with hyperacusis but not misophonia without a significant difference (H>M), and 4 could not discriminate the constructs. Most significant differences survived FDR correction except HQ3. Hyperacusis items related more to sound-based distraction/background noise; misophonia items related more to social impacts of sound.
  • Trigger sounds showed a double dissociation: 5 triggers were more endorsed by those with misophonia plus hyperacusis (house and car alarms, car engines, repetitive barking, typing, sirens), while 3 were more endorsed by those with misophonia without hyperacusis (lip smacking, swallowing, chewing). For CORDS sounds, 13/20 significantly distinguished groups, all with greater endorsement by those reporting hyperacusis. Those with hyperacusis were less likely to have attended many loud concerts (χ²(1) = 5.73, p = .017) and more likely to report sensitive teeth (χ²(1) = 7.08, p = .008). Pain was linked to both constructs; the association between misophonia severity and 12-month pain remained significant (r = 0.21, p = .021) after dropping four SMS pain items.

Methods

  • Participants were 119 adults with self-identified misophonia, recruited from a previous study following a BBC radio interview on 18 May 2021. They completed the Sussex Misophonia Scale (SMS) and a single-item hyperacusis screener initially; 18 months later they completed the HQ and CORDS hyperacusis items via Qualtrics (~30 minutes). No audiological assessment was performed, but participants had to indicate no known hearing loss.
  • The SMS includes 48 specific trigger sounds and 39 Likert-type items (0–4, total 0–156; cut-off 50.5, AUC = 0.91). The hyperacusis screener was based on the Fackrell et al. scoping definition and used a four-point agreement scale. The HQ has 14 items on a four-point scale; CORDS items from Williams et al. (2021) were analysed separately because there was no known way to collapse them into factors or total scores.
  • Analyses compared item-level correlations against SMS total and hyperacusis screener using the Steiger method, with chi-square tests for categorical trigger endorsement and FDR correction for multiple comparisons.

Limitations

  • Stated in the paper: participants did not undergo audiological assessment; hearing loss was excluded only by requiring no known hearing loss. The hyperacusis “ground truth” was a single-item screener rather than a clinical diagnosis, and CORDS items had no established method for collapsing into factors or total scores.
  • Evident from the text: all participants self-identified as having misophonia and were recruited via a BBC radio interview, with a predominantly female sample (79.0%), so findings may not generalise to the general population or to hyperacusis without misophonia. The 18-month lag between initial and later measures may also introduce change or attrition, though the authors frame the associations as reflecting enduring traits. The provided text is truncated before the end of the Discussion, so additional stated limitations may not be visible.

Model-written summary of a shortened version of the paper’s full text (it is longer than we read). Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1080/14992027.2024.2419558

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

0 Valid · 1 Not valid · 6 Not checked · 23 Own results and interpretations

12 more claims

Create a free account to see all 30 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 9
  • Probably not a substantial claim. 6

Create a free account to see these claims.

Statistics recomputed

Every reported test result, recomputed from its test statistic and degrees of freedom. A result shows as not adding up only once an independent check has confirmed it.

  • Consistentχ²(1) = 5.73reported p = .017 · recomputed p = .017

    “χ2(1) = 5.73, p = .017”

  • Consistentχ²(1) = 7.08reported p = .008 · recomputed p = .008

    “χ2(1) = 7.08, p = .008”

2 of 2

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

1 of 1

Citations

Cites

Show all 23 references

Research works printed but not linked: 1

  1. 10.1002/jclp.22098 · DOI · Paper page

Cited by

See all 7

Metadata

Authors
Smees, R., Simner, J., Hoare, D. J., & Ward, J.
Affiliations
  • University of Sussex (GB)
  • University of Nottingham (GB)
Corresponding author
Ward, Jamie
Venue
International Journal of Audiology
Published
2024-10-31
Volume
64
Issue
9
Pages
964-971
ISSN
  • 1499-2027 (ISSN-L)
  • 1708-8186
OpenAlex
W4403989428
Cited by
7
References
23
Citations by year
2026: 4 · 2025: 2 · 2024: 1
FWCI
1.94
Type
journal article
Language
en
Open access
Locations
  • International Journal of Audiology (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Repository@Nottingham (University of Nottingham) (publishedVersion, other-oa)
  • Figshare (submittedVersion, cc-by)
Funders
  • REAM Foundation
  • National Institute for Health and Care Research
  • Department of Health and Social Care
  • NIHR Nottingham Biomedical Research Centre
Topics
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
  • Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
  • Physical Sciences › Physics and Astronomy › Acoustics and Ultrasonics › Noise Effects and Management
Keywords
hyperacusis, misophonia, sound intolerance, sound tolerance, double dissociation
MeSH terms
Adolescent, Adult, Aged, Auditory Perception, Female, Hearing Disorders, Humans, Male, Middle Aged, Noise, Surveys and Questionnaires, Hyperacusis, Severity of Illness Index, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dissociable effects of hyperacusis and misophonia severity imply different mechanisms of decreased sound tolerance. https://app.cochat.ai/papers/10.1080/14992027.2024.2419558
The paper
Smees, R., Simner, J., Hoare, D. J., & Ward, J. (2025). Dissociable effects of hyperacusis and misophonia severity imply different mechanisms of decreased sound tolerance. International Journal of Audiology. https://doi.org/10.1080/14992027.2024.2419558

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.