Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Efficacy of a Technique for Exposing the Mouse Lung to Particles Aspirated from the Pharynx

Rao, G. V. S., Tinkle, Sally, Weissman, David, Antonini, James, Kashon, Michael, Salmen, Rebecca, Battelli, Lori, Willard, Patsy, Hubbs, Ann, Hoover, Mark·2003·Journal of Toxicology and Environmental Health, Part A

Abstract

Recent studies have demonstrated that the mouse lung can be exposed to soluble antigens by aspiration of these antigens from the pharynx. This simple technique avoids the trauma associated with intratracheal instillation. In this study, the pharyngeal aspiration technique was validated for exposing the mouse lung to respirable particles. Using respirable fluorescent amine-modified polystyrene latex beads and beryllium oxide particles, we investigated the localization of aspirated particles within the lung and the relationship between the amount of material placed in the pharynx and the amount deposited in the lung. For exposure, mice were anesthetized with isoflurane in a bell jar, placed on a slant board, and the tongue was gently held in full extension while a 50-microl suspension of particles was pipetted onto the base of the tongue. Tongue restraint was maintained until at least two breaths were completed. Less than a minute after exposure, all mice awoke from anesthesia without visible sequela. There were no significant differences in particle distribution between the left and right side of the lung (p=.16). Particles were widely disseminated in a peribronchiolar pattern within the alveolar region. There was a linear and significant correlation (r2=.99) between the amount administered and the amount deposited in the lung. In beryllium-exposed mice, measurable lung beryllium was 77.5 to 88.2% of the administered beryllium. These findings demonstrate that following aspiration of pharyngeal deposited particles, exposures to the deep lung are repeatable, technically simple, and highly correlated to the administered dose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/15287390306417

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 216

Metadata

Authors
Rao, G. V. S., Tinkle, S., Weissman, D., Antonini, J., Kashon, M., Salmen, R., Battelli, L., Willard, P., Hubbs, A., & Hoover, M.
Venue
Journal of Toxicology and Environmental Health, Part A
Published
2003-01
Volume
66
Issue
15-16
Pages
1441-1452
ISSN
  • 0098-4108 (ISSN-L)
  • 1528-7394
  • 1087-2620
OpenAlex
W2036010329
Cited by
216
References
1
FWCI
2.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy of a Technique for Exposing the Mouse Lung to Particles Aspirated from the Pharynx. https://app.cochat.ai/papers/10.1080/15287390306417
The paper
Rao, G. V. S., Tinkle, S., Weissman, D., Antonini, J., Kashon, M., Salmen, R., Battelli, L., Willard, P., Hubbs, A., & Hoover, M. (2003). Efficacy of a Technique for Exposing the Mouse Lung to Particles Aspirated from the Pharynx. Journal of Toxicology and Environmental Health, Part A. https://doi.org/10.1080/15287390306417

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.