Parameters that Bias the Measurement of Airborne Concentration Within a Respirator
The DOI matches its Crossref record.
Abstract
This paper describes the theoretical basis upon which a test system has been set up to evaluate the sampling error associated with in-facepiece sampling on half-mask respirators. The in-facepiece sampling technique evaluated in this study is the one currently used in the U.S. to conduct quantitative facepiece fit testing. An experimental design was developed to study the sampling bias associated with in-facepiece sampling when selected parameters of the man/respirator system were varied. The results indicated that significant errors can be made in estimating concentration within a respirator when the current in-facepiece sampling technique is employed. Sampling bias was determined when in-facepiece samples were collected only during the inhalation phase of the respiratory cycles. They were found to range from greater than -99% to greater than +98%. The mean sampling bias was -17 +/- 38%. When measured in-facepiece concentrations were used to calculate a fit factor the resulting range was 44 to 4728 even though the actual fit factor was only 87. Based upon the data presented, it was hypothesized that faceseal leakage was streamlining within the respirator cavity. As a result, quantitative facepiece fit data on half-mask respirators may be biased by the large measurement error.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Still being checked.
Cited by
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
An upper bound on one-to-one exposure to infectious human respiratory particles
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2110117118 · Cited by 144
Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
(2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep062 · Cited by 42
Cho, K. J., Jones, S., Jones, G., McKay, R., Grinshpun, S. A., Dwivedi, A., Shukla, R., Singh, U., & Reponen, T. (2010) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2010.513910 · Cited by 40
Respirator Protection and Acceptability Among Agricultural Workers
Popendorf, W. J., Merchant, J. A., Leonard, S., Burmeister, L. F., & Olenchock, S. A. (1995) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1995.10387652 · Cited by 34
Han, D.-H., Willeke, K., & Colton, C. E. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012874 · Cited by 29
Comparison of Three Commercially Available Fit-Test Methods
Janssen, L. L., Luinenburg, M. D., Mullins, H. E., & Nelson, T. J. (2002) · AIHA Journal · doi:10.1080/15428110208984767 · Cited by 36
Tucson Fire Fighter Exposure to Products of Combustion: A Risk Assessment
Burgess, J. L., & Crutchfield, C. D. (1995) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1995.10387609 · Cited by 14
Coffey, C. C., Campbell, D. L., & Myers, W. R. (1999) · American Industrial Hygiene Association Journal · doi:10.1080/00028899908984454 · Cited by 13
Self-citationLee, S.-A., Reponen, T., Li, W., Trunov, M. A., Willeke, K., & Grinshpun, S. A. (2004) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2004.07.0005 · Cited by 11
Мухаметзанов, И. Т., Grinshpun, S. A., Zaripov, S. K., & Камилевич, Г. А. (2016) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2015.07.0466 · Cited by 10
Rose, J. C., Oestenstad, R. K., & Rose, V. E. (1990) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1990.10387791 · Cited by 10
Willeke, K., & Krishnan, U. (1990) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1990.10387785 · Cited by 10
Respiratory Protective Equipment
Myers, W. R. (2001) · Wiley eBooks · doi:10.1002/0471435139.hyg032 · Cited by 8
Self-citationOestenstad, R. K., & Zwissler, A. M. (1991) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1991.10389729 · Cited by 7
On Evaluation of Effectiveness of Respiratory Protective Devices
Капцов, Va, K., Чиркин, & Chirkin, A. V. (2015) · Safety in Technosphere · doi:10.12737/16958 · Cited by 6
A Validation Study of Respirator Fit Testing by Controlled Negative Pressure
Crutchfield, C. D., Ruiz, A. M., & Ruiz, A. M. (1994) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1994.10388328 · Cited by 6
Prototype Sampling System for Measuring Workplace Protection Factors for Gases and Vapors
Groves, W. A., & Reynolds, S. J. (2003) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220301360 · Cited by 7
Validation of a Quantitative Fit Test for Dust/Fume/Mist Respirators: Part I
Iverson, S. G., Danisch, S. G., Mullins, H. E., & Rudolph, S. K. (1992) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1992.10389173 · Cited by 5
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T. A., McKay, R. T., & Lee, S.-A. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1877051 · Cited by 5
Evaluation of Sampling Probes for Fit Testing N95 Filtering Facepiece Respirators
Bergman, M. S., Viscusi, D. J., Zhuang, Z., & Newcomb, W. E. (2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mes091 · Cited by 6
Effect of Particle Size on Respirator Faceseal Leakage
Myers, W. R., Kim, H., & Kadrichu, N. P. (1990) · Cited by 4
Self-citationRespiratory Protective Equipment
Birkner, J. S., & Colton, C. E. (2011) · Wiley eBooks · doi:10.1002/0471435139.hyg032.pub2 · Cited by 4
Nicas, M. (2024) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.15136 · Cited by 3
Correcting Coal Miner Respirator Total Inward Leakage Values for Respiratory Tract Deposition
Nicas, M. (2023) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxad016 · Cited by 2
Face-masks save us from SARS-CoV-2 transmissionPreprint
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.00375 · Cited by 2
Revisiting the Improvement of Respiratory System Protection of Mining Workers
Cheberyachko, S. I. (2019) · Aspects in Mining & Mineral Science · doi:10.31031/amms.2019.03.000569 · Cited by 1
Quantitative Fit Testing of Respirators: Past, Present, Future
Myers, W. R. (1986) · doi:10.1520/stp42089s · Cited by 1
Self-citationPenetration through the staple punctures on five N95 respirator models
Medina, D. E. (2014) · Digital Commons - University of South Florida (University of South Florida)
Validation of a Respirator Performance Model
Hinds, W. C., Risi, D., & Kuo, T.-L. (1995) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1995.10387697
Yang, L. (2015) · American Journal of Clinical and Experimental Medicine · doi:10.11648/j.ajcem.20150305.32
Groce, D. W. (2007) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.8960
Rousseau, R. F., Lotti, J. M., Ouvrai, A., Hubert-Pelle, G., & Silvente, É. (2007) · HAL
Simulation-based assessment for N95 filtering facepiece respirator
Lei, Z. (2014) · ThinkTech (Texas Tech University)
Exercise protocols and their effects on quantitative respirator fit tests
Boothe, G. D. (1989) · UA Campus Repository (The University of Arizona)
Pham, L. T. K. (1989) · UA Campus Repository (The University of Arizona)
Metadata
- Authors
- MYERS, W. R., ALLENDER, J., PLUMMER, R., & STOBBE, T.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- West Virginia University (US)
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1986-02
- Volume
- 47
- Issue
- 2
- Pages
- 106-114
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2059282197
- Cited by
- 36
- References
- 0
- Citations by year
- 2024: 1 · 2023: 1 · 2021: 3 · 2016: 1 · 2015: 2 · 2014: 2 · 2012: 1
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Industrial and Mining Safety
- Keywords
- half-mask respirators, sampling bias, fit factor
- MeSH terms
- Acetone, Aerosols, Air, Air Pollutants, Humans, Methods, Models, Biological, Quality Control, Respiration, Ventilators, Mechanical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.