Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
Open accessAbstract
The aim of this study was to investigate respirator filter and faceseal penetration of particles representing bacterial and fungal spore size ranges (0.7-4 mum). First, field experiments were conducted to determine workplace protection factors (WPFs) for a typical N95 filtering facepiece respirator (FFR). These data (average WPF = 515) were then used to position the FFR on a manikin to simulate realistic donning conditions for laboratory experiments. Filter penetration was also measured after the FFR was fully sealed on the manikin face. This value was deducted from the total penetration (obtained from tests with the partially sealed FFR) to determine the faceseal penetration. All manikin experiments were repeated using three sinusoidal breathing flow patterns corresponding to mean inspiratory flow rates of 15, 30, and 85 l min(-1). The faceseal penetration varied from 0.1 to 1.1% and decreased with increasing particle size (P < 0.001) and breathing rate (P < 0.001). The fractions of aerosols penetrating through the faceseal leakage varied from 0.66 to 0.94. In conclusion, even for a well-fitting FFR respirator, most particle penetration occurs through faceseal leakage, which varies with breathing flow rate and particle size.
Overview
CoChat Summary
TL;DR
This manikin- and field-based study examined penetration of 0.7–4 µm particles through N95 filtering facepiece respirator filters and faceseal leaks under cyclic breathing. It found that for a well-fitting N95, most particle penetration occurred through faceseal leakage, which decreased with increasing particle size and breathing rate.
Key findings
- In the pilot field study with 13 agricultural workers, the N95 FFR had an average workplace protection factor (WPF) of 515, with unadjusted values ranging from 12 to 9531; laboratory protection factors ranged from 71 to 1161 and mostly fell within the 95% confidence interval of field WPFs.
- Unadjusted faceseal penetration ranged from 0.11 to 1.07%, while filter penetration ranged from 0.04 to 0.19%. Faceseal penetration decreased significantly with increasing particle size and increasing mean inspiratory flow (MIF) (both P < 0.001), whereas filter penetration slightly increased with breathing rate (P = 0.02).
- The ratio of faceseal to filter penetration varied from 1.9 to 16.1, and the fraction of aerosol penetrating through the faceseal leak varied from 0.66 to 0.94, indicating faceseal leakage accounted for most total penetration.
- Faceseal penetration correlated strongly with total penetration (R² = 0.97) but not with filter penetration when all data were pooled (R² = 0.07); when analyzed separately by flow rate, correlations were R² = 0.96 at 15 L min⁻¹, 0.90 at 30 L min⁻¹, and 0.91 at 85 L min⁻¹.
Methods
- A pilot field study measured WPF for 13 human subjects wearing a NIOSH-approved N95 FFR on three agricultural farms (horse, swine, and corn), using a personal sampling system with optical particle counters across 0.7–10 µm size channels.
- Manikin experiments used the same N95 FFR on a hard plastic breathing manikin in a 24.3 m³ chamber, with sinusoidal cyclic flows at MIF = 15, 30, and 85 L min⁻¹. The respirator was fully sealed to measure filter penetration and partially sealed (11 cm seal on each side) to simulate field faceseal leakage; faceseal penetration was calculated as total minus filter penetration.
- Challenge aerosol was ISO 12103-1 A1 test dust generated with a Koken nebulizer in 2-propanol, charge-neutralized, and measured inside and outside the respirator. Statistical analysis used SAS 9.1.3 with ANOVA/general linear models on transformed penetration values and paired t-tests.
Limitations
- The paper states that the relatively high sampling flow rate (10 L min⁻¹) may affect measured penetration, especially when respiration flow rates are comparable; the largest particle size range (mean 7.5 µm) was excluded due to low outside concentration; and the manikin had fixed faceseal leakage whose shape and size were unknown and likely fluctuates in real workers.
- The paper also notes that manikin PFs did not account for particles returning to the respirator cavity during human exhalation; human respiratory deposition of 39–96% for 0.7–5 µm particles under medium workload could cause up to 1.6 times higher PF in manikin experiments even with identical leakage.
- Evident from the text: filter penetration at 4 µm was below the detection limit, so faceseal penetration for that size was assumed equal to total penetration rather than independently measured.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
4 Valid · 0 Not valid · 15 Not checked · 50 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“The results are in accordance with the findings of Coffey et al. (1998) who reported that faceseal leakage was the largest component of total penetration for a given respirator (Coffey et al., 1998).”
§ Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow > DISCUSSION AND CONCLUSIONS
What the sources say
- Supportedcites Coffey et al. (1998) source
In the ‘Effect of Face-seal Leakage on Respirator Performance’ section, the paper states that face-seal leakage was by far the largest component of total penetration for each of the 21 respirators. No page number is provided in the supplied passage. (LLM, conf=0.95)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The fractions of aerosols penetrating through the faceseal leakage varied from 0.66 to 0.94.”
§ Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The aerosol fraction penetrating through the faceseal leak relative to the fraction penetrating through the filter material increased significantly with the increase in particle size (P , 0.001) and with the decrease in the breathing rate (P , 0.001), varying from 6.2 to 16.1 at MIF 5 15 l min À1 , from 2.9 to 6.2 at MIF 5 30 l min À1 , and from 1.9 to 4.1 at MIF 5 85 l min À1 .”
§ Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow > RESULTS
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“However, no correlation was found between the faceseal penetration and the filter penetration when all data were included in the analysis (R 2 5 0.07).”
§ Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow > RESULTS
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Significant correlation was demonstrated between the faceseal penetration and the total penetration (R 2 5 0.97).”
- Also stated in: § DISCUSSION AND CONCLUSIONS · boosted
“The faceseal penetration correlated highly with the total penetration.”
§ Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow > RESULTS
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § DISCUSSION AND CONCLUSIONS · boosted
27 more claims
Create a free account to see all 69 claims and every source verdict.
- Probably not a substantial claim. 16
- It may state two separate claims as one. 26
- The quote only partly states this claim. 2
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow > Pilot-scale field experiment
“the WPF of an N95 FFR was determined for 13 human subjects on three different agricultural farms (horse farm, swine confinement, and corn farm).”
§ Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow > DISCUSSION AND CONCLUSIONS
“the concentration in the field was averaged from four agricultural farms where WPF was measured for 13 human subjects.”
Citations
Cites
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235
Self-citation(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mei058 · Cited by 234
Self-citationFilter Performance of N99 and N95 Facepiece Respirators Against Viruses and Ultrafine Particles
Eninger, R. M., Honda, T., Adhikari, A., Heinonen-Tanski, H., Reponen, T., & Grinshpun, S. A. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men019 · Cited by 165
Self-citationElectrostatic Respirator Filter Media: Filter Efficiency and Most Penetrating Particle Size Effects
Martin, S. B., & Moyer, E. S. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050075617 · Cited by 156
Comparison of Performance of Three Different Types of Respiratory Protection Devices
Lawrence, R. B., Duling, M. G., Calvert, C. A., & Coffey, C. C. (2006) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620600829211 · Cited by 127
Penetration of 4.5nm to aerosol particles through fibrous filters
Huang, S.-H., Chen, C.-W., Chang, C.-P., Lai, C.-Y., & Chen, C.-C. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.05.007 · Cited by 108
N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic Flow
Eshbaugh, J. P., Gardner, P. D., Richardson, A. W., & Hofacre, K. C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802558196 · Cited by 84
(1951) · PubMed · Cited by 80
Lee, S.-A., Adhikari, A., Grinshpun, S. A., McKay, R., Shukla, R., Zeigler, H. L., & Reponen, T. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500330583 · Cited by 73
Self-citationThe Effects of Particle Charge on the Performance of a Filtering Facepiece
Chen, C.-C., & Huang, S.-H. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010488 · Cited by 72
Research works printed but not linked: 5
- 1998, J INT SOC RESPIR PROT, 16, 25
- 2009, J INT SOC RESPIR PROT, 25, 75
- Johnson, 1993, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering, 5, 265
- 1951, ARCH IND HYG OCCUP MED, 3, 461
- 1998, J INT SOC RESPIR PROT, 16, 11
Cited by
Evaluating the Efficacy of Cloth Facemasks in Reducing Particulate Matter Exposure
Shakya, K. M., Noyes, A., Kallin, R., & Peltier, R. E. (2017) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2016.42 · Cited by 202
Lai, A. C. K., Poon, C. K. M., & Cheung, A. C. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0537 · Cited by 166
An upper bound on one-to-one exposure to infectious human respiratory particles
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2110117118 · Cited by 143
“particle size for particles larger than 300 nm, which agrees with the literature [14, 54, 55, 56, 57, 58, 49].”
He, X., Reponen, T., McKay, R. T., & Grinshpun, S. A. (2013) · Aerosol Science and Technology · doi:10.1080/02786826.2013.829209 · Cited by 64
“Other FFR performance studies have reported decreased inward leakage with increasing the breathing flow (Cho et al. 2010b; Rengasamy and Eimer 2011; He et al. 2013c).”
BackgroundMethodResultInfluentialSelf-citationImpact of structural features on dynamic breathing resistance of healthcare face mask
Yao, B.-G., Wang, Y., Ye, X., Zhang, F., & Peng, Y.-L. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.06.463 · Cited by 56
Metadata
- Authors
- Cho, K. J., Reponen, T. A., McKay, R. T., Shukla, R., Haruta, H., Sekar, P., & Grinshpun, S. A.
- Affiliations
- University of Cincinnati (US)
- Koken (Japan) (JP)
- Corresponding author
- Tiina A. Reponen
- Venue
- The Annals of Occupational Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-08-21
- Volume
- 54
- Issue
- 1
- Pages
- 68-77
- ISSN
- 0003-4878 (ISSN-L)
- 1475-3162
- PMC
- PMC6768069
- OpenAlex
- W2116255018
- Cited by
- 42
- References
- 20
- Citations by year
- 2024: 1 · 2023: 1 · 2022: 5 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 2 · 2016: 3 · 2015: 1 · 2014: 4 · 2013: 9 · 2012: 2
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- The Annals of Occupational Hygiene (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- National Institute for Occupational Safety and Health (R01 OH004085, R01 OH04085)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- N95 respirators, filtering facepiece respirators, filter penetration, particle penetration, workplace protection factor, particle size, bacterial spores, fungal spores, respirator fit
- MeSH terms
- Adult, Aerosols, Agriculture, Air Pollutants, Occupational, Equipment Design, Filtration, Humans, Manikins, Materials Testing, Particle Size, Pilot Projects, Respiratory Protective Devices, Occupational Exposure, Equipment Failure Analysis, Inhalation Exposure, Particulate Matter, Respiratory Rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow. https://app.cochat.ai/papers/10.1093/annhyg/mep062
- The paper
- Cho, K. J., Reponen, T. A., McKay, R. T., Shukla, R., Haruta, H., Sekar, P., & Grinshpun, S. A. (2009). Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow. The Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/mep062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.