Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow

Open access
Kyungmin Jacob Cho, Tiina A. Reponen, Roy Thomas McKay, Rakesh Shukla, Hiroki Haruta, Padmini Sekar, Sergey A. Grinshpun · 2009 · The Annals of Occupational Hygiene

Abstract

The aim of this study was to investigate respirator filter and faceseal penetration of particles representing bacterial and fungal spore size ranges (0.7-4 mum). First, field experiments were conducted to determine workplace protection factors (WPFs) for a typical N95 filtering facepiece respirator (FFR). These data (average WPF = 515) were then used to position the FFR on a manikin to simulate realistic donning conditions for laboratory experiments. Filter penetration was also measured after the FFR was fully sealed on the manikin face. This value was deducted from the total penetration (obtained from tests with the partially sealed FFR) to determine the faceseal penetration. All manikin experiments were repeated using three sinusoidal breathing flow patterns corresponding to mean inspiratory flow rates of 15, 30, and 85 l min(-1). The faceseal penetration varied from 0.1 to 1.1% and decreased with increasing particle size (P < 0.001) and breathing rate (P < 0.001). The fractions of aerosols penetrating through the faceseal leakage varied from 0.66 to 0.94. In conclusion, even for a well-fitting FFR respirator, most particle penetration occurs through faceseal leakage, which varies with breathing flow rate and particle size.

Overview

CoChat Summary

TL;DR

This manikin- and field-based study examined penetration of 0.7–4 µm particles through N95 filtering facepiece respirator filters and faceseal leaks under cyclic breathing. It found that for a well-fitting N95, most particle penetration occurred through faceseal leakage, which decreased with increasing particle size and breathing rate.

Key findings

  • In the pilot field study with 13 agricultural workers, the N95 FFR had an average workplace protection factor (WPF) of 515, with unadjusted values ranging from 12 to 9531; laboratory protection factors ranged from 71 to 1161 and mostly fell within the 95% confidence interval of field WPFs.
  • Unadjusted faceseal penetration ranged from 0.11 to 1.07%, while filter penetration ranged from 0.04 to 0.19%. Faceseal penetration decreased significantly with increasing particle size and increasing mean inspiratory flow (MIF) (both P < 0.001), whereas filter penetration slightly increased with breathing rate (P = 0.02).
  • The ratio of faceseal to filter penetration varied from 1.9 to 16.1, and the fraction of aerosol penetrating through the faceseal leak varied from 0.66 to 0.94, indicating faceseal leakage accounted for most total penetration.
  • Faceseal penetration correlated strongly with total penetration (R² = 0.97) but not with filter penetration when all data were pooled (R² = 0.07); when analyzed separately by flow rate, correlations were R² = 0.96 at 15 L min⁻¹, 0.90 at 30 L min⁻¹, and 0.91 at 85 L min⁻¹.

Methods

  • A pilot field study measured WPF for 13 human subjects wearing a NIOSH-approved N95 FFR on three agricultural farms (horse, swine, and corn), using a personal sampling system with optical particle counters across 0.7–10 µm size channels.
  • Manikin experiments used the same N95 FFR on a hard plastic breathing manikin in a 24.3 m³ chamber, with sinusoidal cyclic flows at MIF = 15, 30, and 85 L min⁻¹. The respirator was fully sealed to measure filter penetration and partially sealed (11 cm seal on each side) to simulate field faceseal leakage; faceseal penetration was calculated as total minus filter penetration.
  • Challenge aerosol was ISO 12103-1 A1 test dust generated with a Koken nebulizer in 2-propanol, charge-neutralized, and measured inside and outside the respirator. Statistical analysis used SAS 9.1.3 with ANOVA/general linear models on transformed penetration values and paired t-tests.

Limitations

  • The paper states that the relatively high sampling flow rate (10 L min⁻¹) may affect measured penetration, especially when respiration flow rates are comparable; the largest particle size range (mean 7.5 µm) was excluded due to low outside concentration; and the manikin had fixed faceseal leakage whose shape and size were unknown and likely fluctuates in real workers.
  • The paper also notes that manikin PFs did not account for particles returning to the respirator cavity during human exhalation; human respiratory deposition of 39–96% for 0.7–5 µm particles under medium workload could cause up to 1.6 times higher PF in manikin experiments even with identical leakage.
  • Evident from the text: filter penetration at 4 µm was below the detection limit, so faceseal penetration for that size was assumed equal to total penetration rather than independently measured.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1093/annhyg/mep062

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

4 Valid · 0 Not valid · 15 Not checked · 50 Own results and interpretations

27 more claims

Create a free account to see all 69 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 16
  • It may state two separate claims as one. 26
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 20 references

Research works printed but not linked: 5

  1. 1998, J INT SOC RESPIR PROT, 16, 25
  2. 2009, J INT SOC RESPIR PROT, 25, 75
  3. Johnson, 1993, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering, 5, 265
  4. 1951, ARCH IND HYG OCCUP MED, 3, 461
  5. 1998, J INT SOC RESPIR PROT, 16, 11

Cited by

See all 42

Metadata

Authors
Cho, K. J., Reponen, T. A., McKay, R. T., Shukla, R., Haruta, H., Sekar, P., & Grinshpun, S. A.
Affiliations
  • University of Cincinnati (US)
  • Koken (Japan) (JP)
Corresponding author
Tiina A. Reponen
Venue
The Annals of Occupational Hygiene
Published
2009-08-21
Volume
54
Issue
1
Pages
68-77
ISSN
  • 0003-4878 (ISSN-L)
  • 1475-3162
OpenAlex
W2116255018
Cited by
42
References
20
Citations by year
2024: 1 · 2023: 1 · 2022: 5 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 2 · 2016: 3 · 2015: 1 · 2014: 4 · 2013: 9 · 2012: 2
FWCI
1.68
Type
journal article
Language
en
Open access
Locations
  • The Annals of Occupational Hygiene (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • HighWire Press Open Archive (submittedVersion)
Funders
National Institute for Occupational Safety and Health (R01 OH004085, R01 OH04085)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
Keywords
N95 respirators, filtering facepiece respirators, filter penetration, particle penetration, workplace protection factor, particle size, bacterial spores, fungal spores, respirator fit
MeSH terms
Adult, Aerosols, Agriculture, Air Pollutants, Occupational, Equipment Design, Filtration, Humans, Manikins, Materials Testing, Particle Size, Pilot Projects, Respiratory Protective Devices, Occupational Exposure, Equipment Failure Analysis, Inhalation Exposure, Particulate Matter, Respiratory Rate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow. https://app.cochat.ai/papers/10.1093/annhyg/mep062
The paper
Cho, K. J., Reponen, T. A., McKay, R. T., Shukla, R., Haruta, H., Sekar, P., & Grinshpun, S. A. (2009). Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow. The Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/mep062

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.