EVALUATION OF EIGHT BIOAEROSOL SAMPLERS CHALLENGED WITH AEROSOLS OF FREE BACTERIA
The DOI matches its Crossref record.
Abstract
The need to quantify airborne microorganisms in the commercial microbiology industry (biotechnology) and during evaluations of indoor air quality, infectious disease outbreaks, and agriculture health investigations has shown there is a major technological void in bioaerosol sampling techniques to measure and identify viable and nonviable aerosols. As commercialization of microbiology increases and diversifies, it is increasingly necessary to assess occupational exposure to bioaerosols. Meaningful exposure estimates, by using area or environmental samplers, can only be ensured by the generation of data that are both precise and accurate. The Andersen six-stage viable (microbial) particle sizing sampler (6-STG) and the Ace Glass all-glass impinger-30 (AGI-30) have been suggested as the samplers of choice for the collection of viable microorganisms by the International Aerobiology Symposium and the American Conference of Governmental Industrial Hygienists. Some researchers consider these samplers inconvenient for evaluating industrial bioprocesses and indoor or outdoor environments. Alternative samplers for the collection of bioaerosols are available; however, limited information has been reported on their collection efficiencies. A study of the relative sampling efficiencies of eight bioaerosol samplers has been completed. Eight samplers were individually challenged with a bioaerosol, created with a Collison nebulizer, of either Bacillus subtilis or Escherichia coli. The samplers were evaluated under controlled conditions in a horizontal bioaerosol chamber. During each experimental run, simultaneous samples were collected with a reference AGI-30 to verify the concentration of microorganisms in the chamber from run to run and day to day. The results of this research indicate a wide variation in sample collection efficiency for free bacteria (i.e., mostly single cells of E. coli and B. subtilis, dac≥2µm). The particle concentration in the aerosol chamber, as indicated by the AGI-30 sampler, was 2000±85 colony-forming units per cubic meter (CFU/m3)for E. coli and 1170±400 CFUlm3 for B. subtilis. The collection efficiency of the evaluated AGI-30 relative to the reference AGI-30 was 101% + 4%. The 6-STG oversampled the reference AGI-30 by approximately 7%. However, the Andersen single-stage (1-STG), Mattson-Garvin Slit-to-Agar (STA), and Andersen two-stage (2-STG) samplers undersampled the reference AGI-30 by 7%, 10%, and 33%, respectively. The relative collection efficiencies of the Gelman 47-mm membrane filter (MF), Pool Bioanalysis Italiana surface air system (SAS), and Biotest Reuter centrifugal sampler (RCS) were
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Respiratory Health Hazards in Agriculture
(1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.supplement_1.rccm1585s1 · Cited by 495
The index of microbial air contamination
Pasquarella, C., Pitzurra, O., & Savino, A. (2000) · Journal of Hospital Infection · doi:10.1053/jhin.2000.0820 · Cited by 380
Ghosh, B., Lal, H., & Srivastava, A. (2015) · Environment International · doi:10.1016/j.envint.2015.09.018 · Cited by 376
Cole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Improved Aerosol Collection by Combined Impaction and Centrifugal Motion
willeke, K., Lin, X., & Grinshpun, S. A. (1998) · Aerosol Science and Technology · doi:10.1080/02786829808965536 · Cited by 247
Effect of impact stress on microbial recovery on an agar surface
Stewart, S. L., Grinshpun, S. A., Willeke, K., Terzieva, S., Ulevicius, V, & Donnelly, J. (1995) · Applied and Environmental Microbiology · doi:10.1128/aem.61.4.1232-1239.1995 · Cited by 237
Bioaerosol sampling: Classical approaches, advances, and perspectives
Mainelis, G. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1671950 · Cited by 229
“However, the latter can also become a disadvantage as air passing through filters desiccates the collected particles (Grinshpun et al. 2015; Jensen et al. 1992; Lundholm 1982; Thorne et al. 1992; Wang et al. 2001) minimizing sample recovery via culture methods.”
BackgroundTerzieva, S., Donnelly, J., Ulevicius, V, Grinshpun, S. A., Willeke, K., Stelma, G. N., & Brenner, K. P. (1996) · Applied and Environmental Microbiology · doi:10.1128/aem.62.7.2264-2272.1996 · Cited by 220
The assessment of bioaerosols: A critical review
Griffiths, W. D., & DeCosemo, G. A. L. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90218-6 · Cited by 215
Peccia, J., & Hernandez, M. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.02.029 · Cited by 208
“The loss in viability of vegetative bacteria during filter collection has been well documented, although bacterial and fungal spores show a much higher survival rate than vegetative bacteria and viruses (Agranovski et al., 2004; Jensen et al., 1992; Palmgren et al., 1986).”
Accuracy, Precision, and Method Detection Limits of Quantitative PCR for Airborne Bacteria and Fungi
Hospodsky, D., Yamamoto, N., & Peccia, J. (2010) · Applied and Environmental Microbiology · doi:10.1128/aem.01240-10 · Cited by 205
Gibbs, S. G., Green, C. F., Tarwater, P. M., Mota, L. C., Mena, K. D., & Scarpino, P. V. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.8910 · Cited by 167
“It is possible that the all-glass impingers provided better collection of other organisms or less collection of Staphylococcus spp. compared with the impaction collectors (Jensen et al. 1992).”
BackgroundSelf-citationReview / SynthèseBioaerosols from municipal and animal wastes: background and contemporary issues
Pillai, S. D., & Ricke, S. C. (2002) · Canadian Journal of Microbiology · doi:10.1139/w02-070 · Cited by 164
Metadata
- Authors
- Jensen, P. A., Todd, W. F., Davis, G. N., & Scarpino, P. V.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1992-10
- Volume
- 53
- Issue
- 10
- Pages
- 660-667
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2005828966
- Cited by
- 212
- References
- 0
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.