A Critical Overview of Adsorption Models Linearization: Methodological and Statistical Inconsistencies
The DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.
Abstract
The linearization of adsorption equations is controversial. The estimation of fitting parameters strongly depends on the linearization method, magnitude of experimental error, and data range. Although many studies contrast linear versions of these equations with their non-linear counterparts, linearization is preferred due to its simplicity since a line could be represented with fewer experimental points than a curve. An in-depth analysis was carried out to compare the accuracy of linear and non-linear models. Although different transformations linearize Langmuir isotherms, only one form yields reliable fitting parameters. Linear transformations could also lead to a statistical bias, favoring a model that does not represent the experimental behavior. Similar observations are discussed regarding the pseudo-second-order kinetic model. Linearization of Freundlich isotherms, pseudo-first-order kinetic models, and fixed-bed adsorption models through logarithms implies that attention must be taken on the logarithm limits by properly selecting the data range. Linearization also promotes the incorrect interpretation of models due to oversimplification. The linearized van’t Hoff equation would yield a reasonable fit with fewer experimental points than the non-linear regression, which requires more data to assure convergence. In this sense, there is convincing evidence that non-linear regression is a more robust and reliable tool for adsorption modeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In a study, González-López et al.31 reported that the Ricinus communis plant was capable of accumulating Pb from soils contaminated with Pb-acid battery assisted with selected mycorrhizal fungi.”
From Mechanistic and kinetic modeling of cadmium and lead phytoextraction by Madagascar Periwinkle [Catharanthus roseus (L.) G.Don] in battery waste contaminated soil (2025) · cites this paper as González-López et al. [31]
In the citing paper
“The Freundlich isotherm is an empirical model describing the non-linear adsorption of solutes onto heterogeneous soil surfaces31.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The adsorption of gases on plane surfaces of glass, mica and platinum
Langmuir, I. (1918) · Journal of the American Chemical Society · doi:10.1021/ja02242a004 · Cited by 23,242 · cited 1×
“binding site, which occurs at identical and energetically equivalent binding sites.([41]) On the other hand, the Freundlich model describes a reversible and non-ideal adsorption process.”
BackgroundPseudo-second order model for sorption processes
Ho, Y. S., & McKay, G. (1999) · Process Biochemistry · doi:10.1016/s0032-9592(98)00112-5 · Cited by 17,497 · cited 1×
“On the other hand, the pseudo-second-order model (PSO) assumes that the rate-limiting step involves chemisorption and proposes a second-order proportionality between the adsorption rate and the difference between saturation concentrations.([78]) Applying initial conditions of fresh adsorbent to these differential equa…”
BackgroundInsights into the modeling of adsorption isotherm systems
Foo, K. Y., & Hameed, B. H. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.09.013 · Cited by 8,479 · cited 3×
“demonstrated through mathematical basis that at short times, the PFO and the PSO kinetics are equivalent and that PFO provides a better correlation for initial periods than for longer times.([51]) The application of mathematical transformations to kinetic models leads to simplified linearized forms that have received”
BackgroundMethodInfluentialAbout the Theory of So-Called Adsorption of Soluble Substances
Lagergren, S. K. (1898) · Medical Entomology and Zoology · Cited by 5,210
Guidelines for the use and interpretation of adsorption isotherm models: a review
Al-Ghouti, M. A., & Da'ana, D. A. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.122383 · Cited by 3,535 · cited 1×
“However, the linearization of these equations can modify the statistical interpretation of experimental error distributions, invalidating least-squares assumptions of constant error variance, introduce error into the independent variable, and abnormal fluctuation of measurement errors.([56]) Some authors suggest that…”
BackgroundTran, H. N., You, S.-J., Hosseini-Bandegharaei, A., & Chao, H.-P. (2017) · Water Research · doi:10.1016/j.watres.2017.04.014 · Cited by 2,902 · cited 3×
“Thus, the use of data recorded over a significant time after reaching equilibrium should be avoided, but the range should be broad enough to examine both initial and near equilibrium stages.([29]) If there are not enough data at the early stage, miscalculations are observed in k estimation due to its sensitivity, whil…”
BackgroundInfluentialSimonin, J.-P. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.04.079 · Cited by 2,100 · cited 1×
“If there are not enough data at the early stage, miscalculations are observed in k estimation due to its sensitivity, while the PSO is unable to represent a steep rise in adsorption at short times.([81]) Another critical issue of favoring the PSO model over the PFO model based on linear analysis, is that the contribut…”
MethodLima, E. C., Hosseini-Bandegharaei, A., Moreno-Piraján, J. C., & Anastopoulos, I. (2019) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.10.048 · Cited by 1,882 · cited 4×
“constant occurs, which has been discussed by several papers.[28,114] Other proposals estimate the equilibrium constant considering the activity coefficient, such as the partition coefficient.”
BackgroundMethodInfluentialHeterogeneous Ion Exchange in a Flowing System
Thomas, H. C. (1944) · Journal of the American Chemical Society · doi:10.1021/ja01238a017 · Cited by 1,855 · cited 1×
“process follows an equilibrium described by Langmuir isotherm and obeys second-order reversible reaction kinetics.([91])”
Burakov, A. E., Galunin, E. V., Burakova, I. V., Kucherova, A. E., Agarwal, S., Tkachev, A. G., & Gupta, V. K. (2018) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2017.11.034 · Cited by 1,612 · cited 1×
“Adsorption is governed by mass transfer and the surface chemistry of the sorbent, which requires several experiments to describe equilibrium, kinetics, thermodynamics, or the continuous-flow operation in fixed-beds.([7,8]) Among these studies, adsorption equilibrium is by far the most important subject of adsorption l…”
Background
Cited by
Adsorption kinetics and isotherm models of heavy metals by various adsorbents: An overview
Wang, J., & Guo, X. (2023) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2023.2221157 · Cited by 385
On validity, physical meaning, mechanism insights and regression of adsorption kinetic models
Vareda, J. P. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.121416 · Cited by 380
Hu, Q., Lan, R., He, L., Liu, H., & Pei, X. (2023) · Journal of Environmental Management · doi:10.1016/j.jenvman.2022.117104 · Cited by 248
Multi-component Adsorption Isotherms: Review and Modeling Studies
Amrutha, Jeppu, G., Girish, C. R., Prabhu, B., & Mayer, K. (2023) · Environmental Processes · doi:10.1007/s40710-023-00631-0 · Cited by 188
New use for Lentinus edodes bran biochar for tetracycline removal
Liu, X., Shao, Z., Wang, Y., Liu, Y., Wang, S., Gao, F., & Dai, Y. (2022) · Environmental Research · doi:10.1016/j.envres.2022.114651 · Cited by 147
Metadata
- Authors
- González-López, M. E., Laureano-Anzaldo, C. M., Pérez-Fonseca, A. A., Arellano, M., & Robledo-Ortíz, J. R.
- Venue
- Separation & Purification Reviews
- Publisher
- Informa UK Limited
- Published
- 2021-08
- Volume
- 51
- Issue
- 3
- Pages
- 358-372
- ISSN
- 1542-2119 (ISSN-L)
- 1542-2127
- OpenAlex
- W3188492461
- Cited by
- 167
- References
- 116
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.