Active Versus Passive Cooling During Work in Warm Environments While Wearing Firefighting Protective Clothing
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
This study examined whether active or passive cooling during intermittent work reduced the heat strain associated with wearing firefighting protective clothing (FPC) and self-contained breathing apparatus (SCBA) in the heat (35 degrees Celsius, 50% relative humidity). Fifteen male Toronto firefighters participated in the heat-stress trials. Subjects walked at 4.5 km.h(-1) with 0% elevation on an intermittent work (50 min) and rest (30 min) schedule. Work continued until rectal temperature (T(re)) reached 39.5 degrees Celsius, or heart rate (HR) reached 95% of maximum or exhaustion. One of three cooling strategies, forearm submersion (FS), mister (M), and passive cooling (PC) were employed during the rest phases. Tolerance time (TT) and total work time (WT) (min) were significantly increased during FS (178.7 +/- 13.0 and 124.7 +/- 7.94, respectively) and M (139.1 +/- 8.28 and 95.1 +/- 4.96, respectively), compared with PC (108.0 +/- 3.59 and 78.0 +/- 3.59). Furthermore, TT and WT were significantly greater in FS compared with M. Rates of T(re) increase, HR and T-(sk) were significantly lower during active compared with passive cooling. In addition, HR and T(re) values in FS were significantly lower compared with M after the first rest phase. During the first rest phase, T(re) dropped significantly during FS (approximately 0.4 degree Celsius) compared with M (approximately 0.08 degree Celsius) while PC increased (approximately 0.2 degree Celsius). By the end of the second rest period T(re) was 0.9 degree Celsius lower in FS compared with M. The current findings suggest that there is a definite advantage when utilizing forearm submersion compared with other methods of active or passive cooling while wearing FPC and SCBA in the heat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
The Gross Composition of the Body
SIRI, W. E. (1956) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3110-5.50011-x · Cited by 1,765 · cited 1×
“Body fatness was calculated using the Siri equation.((32))”
MethodGagge, A. P., Stolwijk, J. A. J., & Hardy, J. D. (1967) · Environmental Research · doi:10.1016/0013-9351(67)90002-3 · Cited by 1,093 · cited 2×
“A subjective rating of thermal comfort (RTC) was completed immediately following metabolic gas exchange measurements using a modified version of Gagge et al.(38) The 524 Journal of Occupational and Environmental Hygiene August 2004 RTC scale ranged from 7 (“comfortable”) to 13 (“so hot I am sick and nauseated”).”
MethodThe Technic of Measuring Radiation and Convection
Hardy, J. D., Du Bois, E. F., & Soderstrom, G. F. (1938) · The Journal of Nutrition · doi:10.1093/jn/15.5.461 · Cited by 849
Respiratory weight losses during exercise.
Mitchell, J. W., Nadel, E. R., & Stolwijk, J. A. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.32.4.474 · Cited by 361
An Introduction to Statistical Methods and Data Analysis
Ziegel, E. R., & Ott, L. (1994) · Technometrics · doi:10.2307/1269399 · Cited by 336
CHARACTERIZATION OF THE PHYSICAL DEMANDS OF FIREFIGHTING.: 32
Jamnik, V., & Gledhill, N. (1989) · Medicine and Science in Sports and Exercise · doi:10.1249/00005768-198904001-00032 · Cited by 328
Advances in Biological and Medical Physics
Nias, A. H. W. (1966) · International Journal of Radiation Biology and Related Studies in Physics, Chemistry and Medicine · doi:10.1080/09553006614550861 · Cited by 304
Smith, D. L., Manning, T. S., & Petruzzello, S. J. (2001) · Ergonomics · doi:10.1080/00140130010000910 · Cited by 239
Exercise duration and thermoregulatory responses after whole body precooling
Lee, D. T., & Haymes, E. M. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.6.1971 · Cited by 185 · cited 1×
“Various methods for cooling have been reported, including precooling,((17,18)) liquid and air cooling systems,((16,19,20)) water immersion of the extremities, both hands and feet,((23)) as well as fan cooling.”
Method
Cited by
Jay, O., Capon, A., Berry, P., Broderick, C., de Dear, R., Havenith, G., Honda, Y., Kovats, R. S., Ma, W., Malik, A., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01209-5 · Cited by 737
Cardiovascular Disease in US Firefighters: A Systematic Review
Soteriades, E. S., Smith, D. L., Tsismenakis, A. J., Baur, D. M., & Kales, S. N. (2011) · Cardiology in Review · doi:10.1097/crd.0b013e318215c105 · Cited by 419
“9 L/h during strenuous firefighting activity.(49,59,64) Smith et al(49) reported a 15% reduction in plasma volume after 3 bouts of strenuous firefighting activity that can have significant physiologic impacts, such as decreased stroke volume.”
BackgroundClothing for protection against heat and flames
Rossi, R. (2014) · Protective Clothing · doi:10.1533/9781782420408.1.70 · Cited by 17
Metadata
- Authors
- Selkirk, G. A., McLellan, T. M., & Wong, J.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2004-08
- Volume
- 1
- Issue
- 8
- Pages
- 521-531
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W1986941648
- Cited by
- 166
- References
- 28
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active Versus Passive Cooling During Work in Warm Environments While Wearing Firefighting Protective Clothing. https://app.cochat.ai/papers/10.1080/15459620490475216
- The paper
- Selkirk, G. A., McLellan, T. M., & Wong, J. (2004). Active Versus Passive Cooling During Work in Warm Environments While Wearing Firefighting Protective Clothing. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459620490475216
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.