Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Firefighters' skin may be exposed to chemicals via permeation/penetration of combustion byproducts through or around personal protective equipment (PPE) or from the cross-transfer of contaminants on PPE to the skin. Additionally, volatile contaminants can evaporate from PPE following a response and be inhaled by firefighters. Using polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) as respective markers for non-volatile and volatile substances, we investigated the contamination of firefighters' turnout gear and skin following controlled residential fire responses. Participants were grouped into three crews of twelve firefighters. Each crew was deployed to a fire scenario (one per day, four total) and then paired up to complete six fireground job assignments. Wipe sampling of the exterior of the turnout gear was conducted pre- and post-fire. Wipe samples were also collected from a subset of the gear after field decontamination. VOCs off-gassing from gear were also measured pre-fire, post-fire, and post-decon. Wipe sampling of the firefighters' hands and neck was conducted pre- and post-fire. Additional wipes were collected after cleaning neck skin. PAH levels on turnout gear increased after each response and were greatest for gear worn by firefighters assigned to fire attack and to search and rescue activities. Field decontamination using dish soap, water, and scrubbing was able to reduce PAH contamination on turnout jackets by a median of 85%. Off-gassing VOC levels increased post-fire and then decreased 17–36 min later regardless of whether field decontamination was performed. Median post-fire PAH levels on the neck were near or below the limit of detection (< 24 micrograms per square meter [µg/m2]) for all positions. For firefighters assigned to attack, search, and outside ventilation, the 75th percentile values on the neck were 152, 71.7, and 39.3 µg/m2, respectively. Firefighters assigned to attack and search had higher post-fire median hand contamination (135 and 226 µg/m2, respectively) than other positions (< 10.5 µg/m2). Cleansing wipes were able to reduce PAH contamination on neck skin by a median of 54%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of Average Concentration in the Presence of Nondetectable Values
Hornung, R. W., & Reed, L. D. (1990) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1990.10389587 · Cited by 3,495 · cited 1×
“(41) On average, fluoranthene was the most”
The estimation of areas of burns
Cc, L. (1944) · Medical Entomology and Zoology · Cited by 757
Occupation and cancer – follow-up of 15 million people in five Nordic countries
Pukkala, E., Martinsen, J. I., Lynge, E., Gunnarsdottir, H. K., Sparén, P., Tryggvadottir, L., Weiderpass, E., & Kjaerheim, K. (2009) · Acta Oncologica · doi:10.1080/02841860902913546 · Cited by 718 · cited 1×
“(4-6) While chemical exposures encountered during firefighting are thought to contribute to the elevated risk of these cancers, the role that contamination on PPE and skin plays”
BackgroundDaniels, R. D., Kubale, T. L., Yiin, J. H., Dahm, M. M., Hales, T. R., Baris, D., Zahm, S. H., Beaumont, J. J., Waters, K. M., & Pinkerton, L. E. (2014) · Occupational and Environmental Medicine · doi:10.1136/oemed-2013-101662 · Cited by 334 · cited 1×
“(2) found increased mortality and incidence risk for all cancers, mesothelioma, and cancers of the esophagus, intestine, lung, kidney, and oral cavity, as well as an elevated risk for prostate”
BackgroundSystemic Exposure to PAHs and Benzene in Firefighters Suppressing Controlled Structure Fires
(2014) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meu036 · Cited by 203 · cited 3×
“(30) found significantly elevated levels of PAHs in skin wipes from firefighters’ necks following controlled burns.”
BackgroundInfluentialVanRooij, J. G., Bodelier-Bade, M. M., & Jongeneelen, F. J. (1993) · Occupational and Environmental Medicine · doi:10.1136/oem.50.7.623 · Cited by 190 · cited 1×
“(44, 45) Thus, it is likely that firefighters in this study, especially the interior crews, had biological uptake of PAHs.”
BackgroundCharacterization of Firefighter Exposures During Fire Overhaul
Bolstad-Johnson, D. M., Burgess, J. L., Crutchfield, C. D., Storment, S., Gerkin, R., & Wilson, J. R. (2000) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660008984572 · Cited by 164
Health hazards of fire fighters: exposure assessment.
Brandt-Rauf, P. W., Fallon, L. F., Tarantini, T., Idema, C., & Andrews, L. (1988) · Occupational and Environmental Medicine · doi:10.1136/oem.45.9.606 · Cited by 147 · cited 1×
“(7-9) Toxic substances identified in fire smoke include polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds”
BackgroundExposure of Firefighters to Particulates and Polycyclic Aromatic Hydrocarbons
Baxter, C. S., Hoffman, J. D., Knipp, M. J., Reponen, T. A., & Haynes, E. N. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2014.890286 · Cited by 144 · cited 1×
“(19-24) VOCs and HCN have also been measured off-gassing from turnout gear following use in live fires.”
BackgroundRisk of cancer among firefighters in California, 1988–2007
Tsai, R. J., Luckhaupt, S. E., Schumacher, P., Cress, R. D., Deapen, D. M., & Calvert, G. M. (2015) · American Journal of Industrial Medicine · doi:10.1002/ajim.22466 · Cited by 141 · cited 1×
“(4-6) While chemical exposures encountered during firefighting are thought to contribute to the elevated risk of these cancers, the role that contamination on PPE and skin plays”
Background
Cited by
Graphene Modified Multifunctional Personal Protective Clothing
Bhattacharjee, S., Joshi, R., Chughtai, A. A., & Macintyre, C. R. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201900622 · Cited by 234
Sousa, G., Teixeira, J., Delerue-Matos, C., Sarmento, B., Morais, S., Wang, X., Rodrigues, F., & Oliveira, M. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191912677 · Cited by 59
“Some authors reported increased values of total PAHs on the neck of exposed firefighters compared to other body regions [35,37,42,44].”
Background
Metadata
- Authors
- Fent, K. W., Alexander, B., Roberts, J., Robertson, S., Toennis, C., Sammons, D., Bertke, S., Kerber, S., Smith, D., & Horn, G.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2017-09-22
- Volume
- 14
- Issue
- 10
- Pages
- 801-814
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2693925335
- Cited by
- 181
- References
- 31
- FWCI
- 42.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.