CoChat

Acetaminophen interference with Nova StatStrip® Glucose Meter: case report with bench top confirmation

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Context: Point-of-care glucose meters are an integral part in the assessment of patients with altered mental status. For this reason, glucose meters are checked for interference from commonly encountered substances, including acetaminophen. The Nova StatStrip® glucose meter has previously been reported to be resistant to interference. We report a case of a very high acetaminophen concentration causing interference with this point-of-care glucose meter.Case report: A 25-year-old female presented after an overdose of acetaminophen and diphenhydramine combination product. Patient was minimally responsive, so a point-of-care glucose check was attempted using the Nova StatStrip® glucose meter. Five different meters were attempted, and each showed an error message. Laboratory analysis using Beckman Coulter® Unicel DxC 800 revealed a glucose of 180 mg/dL and an acetaminophen concentration of 465 mg/L. Serum spiked with acetaminophen at different concentrations revealed interference with the Nova StatStrip® glucose meter at a concentration of 399 mg/L and above. To our knowledge, this interference with the Nova StatStrip® glucose meter has not been reported in the medical literature.Conclusion: Very high levels of acetaminophen can interfere with point-of-care glucose meters, even those that have previously been reported to be robust such as the Nova StatStrip® glucose meter. Clinicians should be aware of this possible interference when treating patients with acetaminophen overdose.

Overview

Integrity signals

Registry

Crossref · 10.1080/15563650.2020.1732404

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Cited by

See all 10

Metadata

Authors
Chenoweth, J. A., Dang, L. T., Gao, G., & Tran, N. K.
Affiliations
University of California Davis Medical Center (US)
Corresponding author
Chenoweth, James A.
Venue
Clinical Toxicology
Published
2020-03-06
Volume
58
Issue
11
Pages
1067-1070
ISSN
  • 0009-9309 (ISSN-L)
  • 1556-3650
  • 1556-9519
OpenAlex
W3009315972
Cited by
10
References
11
Citations by year
2025: 3 · 2023: 4 · 2021: 2 · 2020: 1
FWCI
1.05
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Toxicology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Health Sciences › Medicine › Emergency Medicine › Poisoning and overdose treatments
Keywords
paracetamol, point-of-care glucose testing, assay interference, acetaminophen overdose, diphenhydramine, altered mental status
MeSH terms
Acetaminophen, Adult, Blood Glucose, Female, Humans, Reagent Strips, Point-of-Care Systems, Drug Overdose

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.