Electronic adherence monitoring device performance and patient acceptability: a randomized control trial
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: To investigate the performance and patient acceptability of an inhaler electronic monitoring device in a real-world childhood asthma population.Methods: Children 6 to 15 years presenting with asthma to the hospital emergency department and prescribed inhaled corticosteroids were included. Participants were randomized to receive a device with reminder features enabled or disabled for use with their preventer. Device quality control tests were conducted. Questionnaires on device acceptability, utility and ergonomics were completed at six months.Results: A total of 1306 quality control tests were conducted; 84% passed pre-issue and 87% return testing. The most common failure reason was actuation under-recording. Acceptability scores were high, with higher scores in the reminder than non-reminder group (median, 5th-95th percentile: 4.1, 3.1–5.0 versus 3.7, 2.3–4.8; p < 0.001). Most (>90%) rated the device easy to use. Feedback was positive across five themes: device acceptability, ringtone acceptability, suggestions for improvement, effect on medication use, and effect on asthma control.Conclusions: This study investigates electronic monitoring device performance and acceptability in children using quantitative and qualitative measures. Results indicate satisfactory reliability, although failure rates of 13–16% indicate the importance of quality control. Favorable acceptability ratings support the use of these devices in children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
User-Centered Design and Interactive Health Technologies for Patients
DABBS, A. D. V., MYERS, B. A., MC CURRY, K. R., DUNBAR-JACOB, J., HAWKINS, R. P., BEGEY, A., & DEW, M. A. (2009) · CIN: Computers, Informatics, Nursing · doi:10.1097/ncn.0b013e31819f7c7c · Cited by 517
Chan, A. H. Y., Stewart, A. W., Harrison, J., Camargo, C. A., Black, P. N., & Mitchell, E. A. (2015) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(15)00008-9 · Cited by 265
Cited by
Digital Health Technology in Asthma: A Comprehensive Scoping Review
Mosnaim, G., Safioti, G., Brown, R., DePietro, M., Szefler, S. J., Lang, D. M., Portnoy, J. M., Bukstein, D. A., Bacharier, L. B., & Merchant, R. K. (2021) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2021.02.028 · Cited by 117
Digital interventions to improve adherence to maintenance medication in asthma
Chan, A., De Simoni, A., Wileman, V., Holliday, L., Newby, C. J., Chisari, C., Ali, S., Zhu, N., Padakanti, P., Pinprachanan, V., et al. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013030.pub2 · Cited by 105
Self-citationHesso, I., Kayyali, R., Dolton, D.-R., Joo, K., Zacharias, L., Charalambous, A., Lavdaniti, M., Stalika, E., Ajami, T., Acampa, W., et al. (2023) · Radiation Oncology · doi:10.1186/s13014-023-02351-z · Cited by 33
“However, the success of any technological interventions such as the one proposed in INCISIVE hinges on its acceptability and need among potential users [22, 23].”
Background
Metadata
- Authors
- Chan, A. H. Y., Stewart, A. W., Harrison, J., Black, P. N., Mitchell, E. A., & Foster, J. M.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2017-05-03
- Volume
- 14
- Issue
- 5
- Pages
- 401-411
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2609107019
- Cited by
- 38
- References
- 2
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electronic adherence monitoring device performance and patient acceptability: a randomized control trial. https://app.cochat.ai/papers/10.1080/17434440.2017.1322505
- The paper
- Chan, A. H. Y., Stewart, A. W., Harrison, J., Black, P. N., Mitchell, E. A., & Foster, J. M. (2017). Electronic adherence monitoring device performance and patient acceptability: a randomized control trial. Expert Review of Medical Devices. https://doi.org/10.1080/17434440.2017.1322505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.