The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Antibacterial activity and biofilm inhibition by surface modified titanium alloy medical implants following application of silver, titanium dioxide and hydroxyapatite nanocoatings
Open accessAbstract
One of the most common causes of implant failure is peri-implantitis, which is caused by bacterial biofilm formation on the surfaces of dental implants. Modification of the surface nanotopography has been suggested to affect bacterial adherence to implants. Silver nanoparticles are also known for their antibacterial properties. In this study, titanium alloy implants were surface modified following silver plating, anodisation and sintering techniques to create a combination of silver, titanium dioxide and hydroxyapatite (HA) nanocoatings. Their antibacterial performance was quantitatively assessed by measuring the growth of Streptococcus sanguinis, proportion of live/dead cells and lactate production by the microbes over 24 h. Application of a dual layered silver-HA nanocoating to the surface of implants successfully inhibited bacterial growth in the surrounding media (100% mortality), whereas the formation of bacterial biofilm on the implant surfaces was reduced by 97.5%. Uncoated controls and titanium dioxide nanocoatings showed no antibacterial effect. Both silver and HA nanocoatings were found to be very stable in biological fluids with material loss, as a result of dissolution, to be less than 0.07% for the silver nanocoatings after 24 h in a modified Krebs-Ringer bicarbonate buffer. No dissolution was detected for the HA nanocoatings. Thus, application of a dual layered silver-HA nanocoating to titanium alloy implants creates a surface with antibiofilm properties without compromising the HA biocompatibility required for successful osseointegration and accelerated bone healing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bollenl, C. M. L., Lambrechts, P., & Quirynen, M. (1997) · Dental Materials · doi:10.1016/s0109-5641(97)80038-3 · Cited by 1,911
Cited by
Qing, Y., Cheng, L., Li, R., Liu, G., Zhang, Y., Tang, X., Wang, J., Liu, H., & Qin, Y. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s165125 · Cited by 959
Antibiotic‐Free Antibacterial Strategies Enabled by Nanomaterials: Progress and Perspectives
Wang, Y., Yang, Y., Shi, Y., Song, H., & Yu, C. (2020) · Advanced Materials · doi:10.1002/adma.201904106 · Cited by 700
Application of Antimicrobial Nanoparticles in Dentistry
Song, W., & Ge, S. (2019) · Molecules · doi:10.3390/molecules24061033 · Cited by 259
Biofilm and wound healing: from bench to bedside
Goswami, A. G., Basu, S., Banerjee, T., & Shukla, V. K. (2023) · European Journal of Medical Research · doi:10.1186/s40001-023-01121-7 · Cited by 178
Lu, H., Zhang, Y., Xiong, S., Zhou, Y., Xiao, L., Ma, Y., Xiao, Y., & Wang, X. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.699802 · Cited by 36
Metadata
- Authors
- Besinis, A., Hadi, S. D., Le, H. R., Tredwin, C., & Handy, R. D.
- Venue
- Nanotoxicology
- Publisher
- Informa UK Limited
- Published
- 2017-03-16
- Volume
- 11
- Issue
- 3
- Pages
- 327-338
- ISSN
- 1743-5390 (ISSN-L)
- 1743-5404
- OpenAlex
- W2592917363
- Cited by
- 192
- References
- 1
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibacterial activity and biofilm inhibition by surface modified titanium alloy medical implants following application of silver, titanium dioxide and hydroxyapatite nanocoatings. https://app.cochat.ai/papers/10.1080/17435390.2017.1299890
- The paper
- Besinis, A., Hadi, S. D., Le, H. R., Tredwin, C., & Handy, R. D. (2017). Antibacterial activity and biofilm inhibition by surface modified titanium alloy medical implants following application of silver, titanium dioxide and hydroxyapatite nanocoatings. Nanotoxicology. https://doi.org/10.1080/17435390.2017.1299890
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.