Abstract

Carbon nanotubes (CNT) are one of the most promising nanomaterials because of their intrinsic properties. So, it becomes urgent to assess their toxicity. However, CNT are insoluble in aqueous media required for toxicological studies. Thus, we propose a simple method to disperse CNT for toxicological studies using a biomolecule: The albumin. To evaluate this method, several nanotubes were suspended in saline solution (NaCl 0.9%) without or with albumin at a concentration of 0.5 mg/ml or equal as CNT concentration. These suspensions were visually compared to suspensions obtained with classical dispersing methods using Tween 80 or serum. Homogeneity of the suspensions with or without BSA and CNT structure were analyzed by TEM, agglomerates quantification and total carbon dosage. The effect of coupled albumin-CNT was then tested on A549 and U937 cells in vitro and on rats in vivo. Total carbon dosage, agglomerates quantification and TEM revealed that, in the presence of albumin, the tested nanotubes were better dispersed without any modification of their structure. The CNT suspension was tested in vitro and in vivo in rats. Albumin solution alone induced no modification of the biological responses studied (i.e., cell viability in vitro and inflammatory response and histopathology in vivo) compared to the saline. CNT in NaCl or BSA altered cellular viability in vitro in a similar way but results obtained with CNT suspension in the presence of albumin showed a better reproducibility that can be explained by the better homogeneity of the suspensions. CNT in BSA but not in NaCl significantly increased the cell number in BAL and also the number of apparent CNT-containing cells. Taken together, these results highlight the potential importance of CNT dispersion (and thus of the vehicle) for the toxicological studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/17435390701775136

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 70

Metadata

Authors
Elgrabli, D., Abella-Gallart, S., Aguerre-Chariol, O., Robidel, F., Rogerieux, F., Boczkowski, J., & Lacroix, G.
Venue
Nanotoxicology
Published
2007-01
Volume
1
Issue
4
Pages
266-278
ISSN
  • 1743-5390 (ISSN-L)
  • 1743-5404
OpenAlex
W1972831400
Cited by
70
References
7
FWCI
4.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of BSA on carbon nanotube dispersion for in vivo and in vitro studies. https://app.cochat.ai/papers/10.1080/17435390701775136
The paper
Elgrabli, D., Abella-Gallart, S., Aguerre-Chariol, O., Robidel, F., Rogerieux, F., Boczkowski, J., & Lacroix, G. (2007). Effect of BSA on carbon nanotube dispersion for in vivo and in vitro studies. Nanotoxicology. https://doi.org/10.1080/17435390701775136

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.