Numerical comparison of lattice unit cell designs for medical implants by additive manufacturing
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
The aim of this study was to compare traditional strut-based lattices with minimal surface designs using morphological analysis and image-based simulations of design files. While the two types have been studied widely, no direct comparison has ever been done. Surprisingly, there are no major differences in performance between the two types generally, but minimal surface designs do outperform slightly on angular load simulation. However, minimal surface designs in this density range are shown to have very thin walls, potentially making their accurate production more challenging, or more suitable for applications where larger pore sizes and sheet thicknesses may be applicable. Interesting results such as dual pore size distributions and variations in tortuosity of pore networks are demonstrated, with differences between various designs. The results show that all the tested designs are suitable for bone implants, but the best design might be selected based on its specialised performance requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal Additive Manufacturing: A Review
Frazier, W. E. (2014) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-014-0958-z · Cited by 5,984 · cited 1×
“Additive Manufacturing (AM) is a fast-growing class of technologies that uses 3D CAD files to produce complex parts in a layer-by-layer method (Gibson et al. 2010; Frazier 2014; Gu et al. 2012).”
BackgroundCellular solids: Structure and properties
Wolcott, M. P. (1990) · Materials Science and Engineering: A · doi:10.1016/0921-5093(90)90295-e · Cited by 5,926 · cited 3×
“Simulations for each of the 8 models in this work were compared to calculations based on the Ashby–Gibson model for open-cell foams (Gibson and Ashby 1999; Ashby et al. 2000).”
MethodInfluentialThe Lattice Boltzmann Equation for Fluid Dynamics and Beyond
Succi, S. (2001) · doi:10.1093/oso/9780198503989.001.0001 · Cited by 4,188
Porous scaffold design for tissue engineering
Hollister, S. J. (2005) · Nature Materials · doi:10.1038/nmat1421 · Cited by 3,969 · cited 2×
“As described in Hollister (2005), the porosity and stiffness of the lattice structure are interrelated.”
BackgroundLaser additive manufacturing of metallic components: materials, processes and mechanisms
Gu, D. D., Meiners, W., Wissenbach, K., & Poprawe, R. (2012) · International Materials Reviews · doi:10.1179/1743280411y.0000000014 · Cited by 3,197 · cited 1×
“Additive Manufacturing (AM) is a fast-growing class of technologies that uses 3D CAD files to produce complex parts in a layer-by-layer method (Gibson et al. 2010; Frazier 2014; Gu et al. 2012).”
BackgroundAdditive Manufacturing Technologies: Rapid Prototyping to Direct Digital Manufacturing
Gibson, I., Rosen, D. W., & Stucker, B. (2010) · National University of Singapore · doi:10.1007/978-1-4419-1120-9 · Cited by 2,969 · cited 1×
“Additive Manufacturing (AM) is a fast-growing class of technologies that uses 3D CAD files to produce complex parts in a layer-by-layer method (Gibson et al. 2010; Frazier 2014; Gu et al. 2012).”
BackgroundAshby, M. F., Evans, A., Fleck, N. A., Gibson, L. J., Hutchinson, J. W., & Wadley, H. N. G. (2002) · Materials & Design · doi:10.1016/s0261-3069(01)00049-8 · Cited by 2,367
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121 · cited 1×
“The particular requirements of lattices for bone replacement implants have been described in detail in a number of recent reviews (Wang et al. 2016; Tan et al. 2017; Murr 2017; Zhang et al. 2017; Dong et al. 2017).”
BackgroundBoneJ: Free and extensible bone image analysis in ImageJ
Doube, M., Kłosowski, M. M., Arganda-Carreras, I., Cordelières, F. P., Dougherty, R. P., Jackson, J. S., Schmid, B., Hutchinson, J. R., & Shefelbine, S. J. (2010) · Bone · doi:10.1016/j.bone.2010.08.023 · Cited by 2,040
A new method for the model‐independent assessment of thickness in three‐dimensional images
Hildebrand, T., & Rüegsegger, P. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.1340694.x · Cited by 1,818 · cited 8×
“gical methods described in (Thomsen et al. 2005; Hildebrand and Rüegsegger 1997; Hildebrand et al. 1999) and this method is widely in use in biomedical bone analysis, hence the terminology.”
BackgroundMethodInfluentialHildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303 · cited 6×
“These are calculated from volume and surface area of the structure according to the stereological methods described in (Thomsen et al. 2005; Hildebrand and Rüegsegger 1997; Hildebrand et al. 1999) and this method is widely in use in biomedical bone analysis, hence the terminology.”
BackgroundMethodInfluentialTaniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Bobbert, F. S. L., Lietaert, K., Eftekhari, A. A., Pouran, B., Ahmadi, S. M., Weinans, H., & Zadpoor, A. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.024 · Cited by 873
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832 · cited 1×
“…ranges for micro- and macro pores with sizes of 50–1200 µm were indicated for new bone growth and high fixation in orthopaedic or dental applications (Bobyn et al. 1980; Vasconcellos et al. 2010; Taniguchi et al. 2016; LopezHeredia et al. 2008), but the optimum pore size for the replacements of…”
BackgroundMechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)
Parthasarathy, J., Starly, B., Raman, S., & Christensen, A. (2010) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2009.10.006 · Cited by 816
Yan, C., Hao, L., Hussein, A., & Young, P. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.06.024 · Cited by 717 · cited 3×
“Nevertheless, when process parameters are optimised this should not be a limitation, as has been shown before in other studies (Bobbert et al. 2017; Yan et al. 2015; Clymer et al. 2017).”
MethodResultArabnejad, S., Burnett Johnston, R., Pura, J. A., Singh, B., Tanzer, M., & Pasini, D. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.10.048 · Cited by 578
Smith, M., Guan, Z., & Cantwell, W. J. (2013) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2012.12.004 · Cited by 545 · cited 4×
“…been produced by AM and showed positive results in various investigations (Ahmadi et al. 2015; Parthasarathy et al. 2010; Sallica-Leva et al. 2013; Ahmadi et al. 2014; Smith et al. 2013; Bobbert et al. 2017; Yan et al. 2015; Arabnejad et al. 2016), but a direct comparison has not yet been reported.”
BackgroundResultInfluentialTan, X. P., Tan, Y. J., Chow, C. S. L., Tor, S. B., & Yeong, W. Y. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.02.094 · Cited by 514 · cited 1×
“The particular requirements of lattices for bone replacement implants have been described in detail in a number of recent reviews (Wang et al. 2016; Tan et al. 2017; Murr 2017; Zhang et al. 2017; Dong et al. 2017).”
BackgroundMechanical behavior of regular open-cell porous biomaterials made of diamond lattice unit cells
Ahmadi, S. M., Campoli, G., Amin Yavari, S., Sajadi, B., Wauthle, R., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2014) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.02.003 · Cited by 442 · cited 2×
“…unit cell designs have been investigated including for example regular cube-designs (Parthasarathy et al. 2010; Sallica-Leva et al. 2013), diamond (Ahmadi et al. 2014), body-centred cubic and a variation of this with a vertical pillar included (Smith et al. 2013) and minimal surface designs…”
BackgroundResultAhmadi, S., Yavari, S., Wauthle, R., Pouran, B., Schrooten, J., Weinans, H., & Zadpoor, A. (2015) · Materials · doi:10.3390/ma8041871 · Cited by 399
Microstructure and mechanical behavior of porous Ti–6Al–4V parts obtained by selective laser melting
Sallica-Leva, E., Jardini, A. L., & Fogagnolo, J. B. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.05.011 · Cited by 340 · cited 2×
“Various unit cell designs have been investigated including for example regular cube-designs (Parthasarathy et al. 2010; Sallica-Leva et al. 2013), diamond (Ahmadi et al. 2014), body-centred cubic and a variation of this with a vertical pillar included (Smith et al. 2013) and minimal surface designs…”
BackgroundResultA Survey of Modeling of Lattice Structures Fabricated by Additive Manufacturing
Dong, G., Tang, Y., & Zhao, Y. F. (2017) · Journal of Mechanical Design · doi:10.1115/1.4037305 · Cited by 337 · cited 2×
“cement implants have been described in detail in a number of recent reviews (Wang et al. 2016; Tan et al. 2017; Murr 2017; Zhang et al. 2017; Dong et al. 2017).”
BackgroundSing, S. L., Wiria, F. E., & Yeong, W. Y. (2018) · Robotics and Computer-Integrated Manufacturing · doi:10.1016/j.rcim.2017.06.006 · Cited by 302
Zhang, X.-Y., Fang, G., & Zhou, J. (2017) · Materials · doi:10.3390/ma10010050 · Cited by 222
Biomimetics Learning from Nature
(2010) · InTech eBooks · doi:10.5772/198 · Cited by 197
THOMSEN, J. S., LAIB, A., KOLLER, B., PROHASKA, S., MOSEKILDE, L., & GOWIN, W. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01469.x · Cited by 188 · cited 4×
“With the availability of microCT imaging, more accurate 3D thickness measurements could be made from 3D images, with two methods widely in use as described in Thomsen et al. (2005), Hildebrand and Rüegsegger (1997), Hildebrand et al. (1999).”
MethodInfluentialAn Overview of 3-D Printing in Manufacturing, Aerospace, and Automotive Industries
Lim, C. W. J., Le, K. Q., Lu, Q., & Wong, C. H. (2016) · IEEE Potentials · doi:10.1109/mpot.2016.2540098 · Cited by 184 · cited 1×
“Such lightweight designs are useful in aerospace and automotive industries, where strength and mass are most important (Lim et al. 2016).”
BackgroundBagheri, Z. S., Melancon, D., Liu, L., Johnston, R. B., & Pasini, D. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.04.041 · Cited by 162 · cited 2×
“It is also possible to compensate for this type of manufacturing error for lattice struts, as demonstrated by Bagheri et al. (2017).”
BackgroundMurr, L. E. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.02.019 · Cited by 147 · cited 1×
“The particular requirements of lattices for bone replacement implants have been described in detail in a number of recent reviews (Wang et al. 2016; Tan et al. 2017; Murr 2017; Zhang et al. 2017; Dong et al. 2017).”
BackgroundSing, S. L., Yeong, W. Y., Wiria, F. E., & Tay, B. Y. (2016) · Experimental Mechanics · doi:10.1007/s11340-015-0117-y · Cited by 147 · cited 1×
“For example in Sing et al. (2016), struts which should have been approximately 0.8 mmwhere in fact produced in varying thickness depending on production conditions down to as little as 0.2 mm, with significant amounts of partially melted powder on the surface.”
BackgroundInfluentialZADPOOR, A. A., & Hedayati, R. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35855 · Cited by 136 · cited 2×
“More generally, a recent review summarised the analytical relationships available to calculate mechanical properties of a range of lattices (Zadpoor and Hedayati 2016).”
BackgroundHedayati, R., Sadighi, M., Aghdam, M. M., et al. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.11.001 · Cited by 132 · cited 1×
“In a previous study of truncated cube lattices (Hedayati et al. 2016), a similar effect was observed regarding lower experimental mechanical properties than that predicted by modelling.”
ResultMechanics of additively manufactured biomaterials
ZADPOOR, A. A. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.03.018 · Cited by 108 · cited 1×
“Lattice structures are useful for the osseointegration process, while the stiffness of the structure can be matched to that of the bone, eliminating stress-shielding effects typical of current implants (Zadpoor 2017).”
BackgroundOrme, M. E., Gschweitl, M., Ferrari, M., Madera, I., & Mouriaux, F. (2017) · Journal of Mechanical Design · doi:10.1115/1.4037304 · Cited by 92 · cited 1×
“One of the advantages of this PBF technology is the ability to produce highly complex parts, allowing many new lightweight designs to be realised easily (Hollister 2005; Orme et al. 2017).”
BackgroundMeshfree simulation of deforming domains
Shapiro, V., & Tsukanov, I. (1999) · Computer-Aided Design · doi:10.1016/s0010-4485(99)00043-3 · Cited by 84 · cited 1×
“Mesh-free simulation methods were first shown to be useful in Shapiro and Tsukanov (1999), Freytag et al. (2011).”
MethodPrediction of mechanical performance of Ti6Al4V cast alloy based on microCT-based load simulation
du Plessis, A., Yadroitsava, I., le Roux, S. G., Yadroitsev, I. A., Fieres, J., Reinhart, C., & Rossouw, P. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.06.320 · Cited by 66 · cited 2×
“The sameprocedure as in previous studies (du Plessis et al. 2017; Broeckhoven et al. 2017; Broeckhoven and du Plessis 2017) was applied here, with simulation cell size of 40 µm for all lattices.”
MethodSelf-citationBroeckhoven, C., du Plessis, A., & Hui, C. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.06.007 · Cited by 60
Comparison of elastic properties of open‐cell metallic biomaterials with different unit cell types
Hedayati, R., Sadighi, M., Aghdam, M. M., & Hosseini‐Toudeshky, H. (2017) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33854 · Cited by 52
Finite element analysis in situ
Freytag, M., Shapiro, V., & Tsukanov, I. (2011) · Finite Elements in Analysis and Design · doi:10.1016/j.finel.2011.03.001 · Cited by 45 · cited 1×
“Mesh-free simulation methods were first shown to be useful in Shapiro and Tsukanov (1999), Freytag et al. (2011).”
MethodPredicting failure in additively manufactured parts using X-ray computed tomography and simulation
Fieres, J., Schumann, P., & Reinhart, C. (2018) · Procedia Engineering · doi:10.1016/j.proeng.2018.02.008 · Cited by 37 · cited 1×
“This method has been applied in recent studies with great success (Fieres et al. 2018; du Plessis et al. 2017; Broeckhoven et al. 2017; Broeckhoven and du Plessis 2017).”
Method
Cited by
Benedetti, M., du Plessis, A., Ritchie, R. O., Dallago, M., Razavi, N., & Berto, F. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100606 · Cited by 788
du Plessis, A., Yadroitsava, I., & Yadroitsev, I. (2020) · Materials & Design · doi:10.1016/j.matdes.2019.108385 · Cited by 712
Self-citationPlocher, J., & Panesar, A. (2019) · Materials & Design · doi:10.1016/j.matdes.2019.108164 · Cited by 669
Design and Optimization of Lattice Structures: A Review
Pan, C., Han, Y., & Lu, J. (2020) · Applied Sciences · doi:10.3390/app10186374 · Cited by 640
Properties and applications of additively manufactured metallic cellular materials: A review
du Plessis, A., Razavi, N., Benedetti, M., Murchio, S., Leary, M., Watson, M., Bhate, D., & Berto, F. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100918 · Cited by 623
Self-citation
Metadata
- Authors
- du Plessis, A., Yadroitsava, I., Yadroitsev, I., le Roux, S., & Blaine, D.
- Venue
- Virtual and Physical Prototyping
- Publisher
- Informa UK Limited
- Published
- 2018-06-25
- Volume
- 13
- Issue
- 4
- Pages
- 266-281
- ISSN
- 1745-2759 (ISSN-L)
- 1745-2767
- OpenAlex
- W2809735466
- Cited by
- 160
- References
- 41
- FWCI
- 10.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.