CoChat

Impact of data analysis methods for maximal fat oxidation estimation during exercise in sedentary adults: Data analysis maximal fat oxidation

Amaro‐Gahete, Francisco J., Sanchez‐Delgado, Guillermo, Alcantara, Juan M.A., Martinez‐Tellez, Borja, Acosta, Francisco M., Helge, Jørn W., Ruiz, Jonatan R. · 2019 · European Journal of Sport Science
Cited by 38

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

The maximal fat oxidation (MFO), and the exercise intensity that elicits MFO (Fat max), are considered excellent markers of fat metabolism during exercise. Besides individual's biological characteristics (e.g. fed state, physical fitness level, sex, or age), data selection and analysis can affect MFO and Fatmax estimations, yet the effect is unknown. We investigated (i) the impact of using a pre‐defined time interval on MFO and Fat max estimation, and (ii) the impact of applying 2 different data analysis approaches (measured‐values vs. polynomial‐curve) on MFO and Fat max estimations in sedentary adults. A total of 151 (97 women) sedentary adults aged 29.2 ± 13.2 years old participated in the study. We assessed MFO and Fatmax through a walking graded exercise test using indirect calorimetry. We pre‐defined 13 different time intervals for data analysis, and the estimation of MFO and Fat max were performed through the measured‐values and the polynomial‐curve data analysis approaches. There were significant differences in MFO across pre‐defined time intervals methods (P < 0.001) applying measured‐values data analysis approach, while no statistical differences were observed when using polynomial‐curve data analysis approach (P = 0.077). There were no differences in Fat max across pre‐defined time intervals independently of the data analysis approach (P ≥ 0.7). We observed significant differences in MFO between measured‐values and the polynomial‐curve data analysis approaches across the time intervals methods selected (all P ≤ 0.05), and no differences were observed in Fat max (all P ≥ 0.2). In conclusion, our results revealed that there are no differences in MFO and Fat max across different time intervals methods selected using the polynomial‐curve data analysis approach. We observed significant differences in MFO between measured‐values vs. polynomial‐curve data analysis approaches in all the study time intervals, whereas no differences were detected in Fatmax. Therefore, the use of polynomial‐curve data analysis approach allows to compare MFO and Fat max using different time intervals in sedentary adults.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/17461391.2019.1595160

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 38

Metadata

Authors
Amaro‐Gahete, F. J., Sanchez‐Delgado, G., Alcantara, J. M. A., Martinez‐Tellez, B., Acosta, F. M., Helge, J. W., & Ruiz, J. R.
Venue
European Journal of Sport Science
Publisher
Wiley
Published
2019-03-28
Volume
19
Issue
9
Pages
1230-1239
ISSN
  • 1536-7290 (ISSN-L)
  • 1746-1391
OpenAlex
W2927349789
Cited by
38
References
11
FWCI
6.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of data analysis methods for maximal fat oxidation estimation during exercise in sedentary adults: Data analysis maximal fat oxidation. https://app.cochat.ai/papers/10.1080/17461391.2019.1595160
The paper
Amaro‐Gahete, F. J., Sanchez‐Delgado, G., Alcantara, J. M. A., Martinez‐Tellez, B., Acosta, F. M., Helge, J. W., & Ruiz, J. R. (2019). Impact of data analysis methods for maximal fat oxidation estimation during exercise in sedentary adults: Data analysis maximal fat oxidation. European Journal of Sport Science. https://doi.org/10.1080/17461391.2019.1595160

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.