Building energy and comfort management through occupant behaviour pattern detection based on a large-scale environmental sensor network
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Detection of occupant presence has been used extensively in built environments for applications such as demand-controlled ventilation and security. However, the ability to discern the actual number of people in a room is beyond the scope of most current sensing techniques. To address this issue, a complex environmental sensor network is deployed in the Robert L. Preger Intelligent Workplace (IW) at Carnegie Mellon University. The results indicate that there are significant correlations between measured environmental conditions and occupancy status. It is shown that an average of 83% accuracy on the occupancy number detection was achieved by Gaussian Mixture Model based Hidden Markov Models during testing periods. To illustrate the consequent energy impact based on the occupant behaviour detection (i.e. number and duration of occupancy) in the space, an EnergyPlus model of the IW with an assumed standard variable air volume (VAV) system is created. Simulations are conducted to compare the energy consumption consequences between a prescribed occupancy schedule according to the ASHRAE 90.1 base case with the predicted occupancy behaviour. The results show that energy saving of 18.5% can be achieved in the IW while maintaining indoor thermal comfort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An efficient forward-backward algorithm for an explicit-duration hidden Markov model
Yu, S.-Z., & Kobayashi, H. (2003) · IEEE Signal Processing Letters · doi:10.1109/lsp.2002.806705 · Cited by 226 · cited 1×
“The SMM is learned using a forward– backward algorithm (Yu and Kobayashi 2003).”
MethodExplicit modelling of state occupancy in hidden Markov models for automatic speech recognition
Russell, M., & Moore, R. (1985) · ICASSP '85. IEEE International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1985.1168477 · Cited by 194 · cited 2×
“This is consistent with other work in speech recognition (Russell and Moore 1985) and occupancy of single-person offices (Wang et al. 2005).”
Result
Cited by
Rethinking the role of occupant behavior in building energy performance: A review
Zhang, Y., Bai, X., Mills, F. P., & Pezzey, J. C. V. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.05.017 · Cited by 473
Hong, T., D'Oca, S., Turner, W. J. N., & Taylor-Lange, S. C. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.019 · Cited by 322
Digitisation in facilities management: A literature review and future research directions
Wong, J. K. W., Ge, J., & He, S. X. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.04.006 · Cited by 307
Zhao, J., Lasternas, B., Lam, K. P., Yun, R., & Loftness, V. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.07.033 · Cited by 293
Self-citationJung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
Dong, B., & Lam, K. P. (2014) · Building Simulation · doi:10.1007/s12273-013-0142-7 · Cited by 265
Self-citationYang, J., Santamouris, M., & Lee, S. E. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.12.019 · Cited by 226
Occupancy behavior based model predictive control for building indoor climate—A critical review
Mirakhorli, A., & Dong, B. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.07.036 · Cited by 225
Self-citationZou, P. X. W., Xu, X., Sanjayan, J., & Wang, J. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.08.040 · Cited by 215
The impacts of occupant behavior on building energy consumption: A review
Chen, S., Zhang, G., Xia, X., Chen, Y., Setunge, S., & Shi, L. (2021) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101212 · Cited by 205
Aftab, M., Chen, C., Chau, C.-K., & Rahwan, T. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.07.077 · Cited by 201
“More specifically [34] and [35] used predicted occupancy patterns to simulate HVAC con-trol in EnergyPlus, whereas [25, 26] developed LTI MPC algorithms for HVAC control in real buildings.”
MethodDai, X., Liu, J., & Zhang, X. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110159 · Cited by 201
Yang, R., & Wang, L. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.10.025 · Cited by 192
A review of internal and external influencing factors on energy efficiency design of buildings
Chen, S., Zhang, G., Xia, X., Setunge, S., & Shi, L. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109944 · Cited by 184
Modeling occupancy and behavior for better building design and operation—A critical review
Dong, B., Yan, D., Li, Z., Jin, Y., Feng, X., & Fontenot, H. (2018) · Building Simulation · doi:10.1007/s12273-018-0452-x · Cited by 177
Self-citationMobile Device Detection Through WiFi Probe Request Analysis
Oliveira, L., Schneider, D., De Souza, J., & Shen, W. (2019) · IEEE Access · doi:10.1109/access.2019.2925406 · Cited by 52
“In [28], [31], and [32], the authors promoted the combination of data from multiple sensors — such as motion, sound, relative humidity, temperature, light, and CO2 — to monitor occupancy of environments.”
Metadata
- Authors
- Dong, B., & Lam, K. P.
- Venue
- Journal of Building Performance Simulation
- Publisher
- Informa UK Limited
- Published
- 2011-12
- Volume
- 4
- Issue
- 4
- Pages
- 359-369
- ISSN
- 1940-1493 (ISSN-L)
- 1940-1507
- OpenAlex
- W2042804721
- Cited by
- 132
- References
- 2
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.