Determination of anabolic agents in dietary supplements by liquid chromatography-high-resolution mass spectrometry
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A sensitive method for the identification and quantification of anabolic steroids and clenbuterol at trace levels in dietary supplements by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) in atmospheric pressure ionisation (APCI) mode using a single-stage Orbitrap analyser operating at a resolution power of 100 000 full width at half maximum (FWHM) was developed and validated. A total of 1 g of dietary supplement was added with testosterone-d3 as internal standard, dissolved in methanol, evaporated to dryness, diluted in sodium hydroxide solution and extracted with a mixture of pentane/ethyl ether 9:1. The extract was directly injected into the LC-HRMS system. The method was fully validated. Limits of detection (LODs) obtained for anabolic androgenic steroids (AASs) varied from 1 to 25 ng g(-1) and the limit of quantitation (LOQ) was 50 ng g(-1) for all analytes. The calibration was linear for all compounds in the range from the LOQ to 2000 ng g(-1), with correlation coefficients always higher than 0.99. Accuracy (intended as %E) and repeatability (%CV) were always lower than 15%. Good values of matrix effect and recovery were achieved. The ease of the sample preparation together with a fast run time of only 16 min permitted rapid identification of the analytes. The method was applied to the analysis of 30 dietary supplements in order to check for the presence of anabolic agents not labelled as being present in these supplements. Many AASs were often detected in the same sample: indeed, androstenedione was detected in nine supplements, 5-androsten-3β-ol-17-one (DHEA) in 12, methandienone in three, stanozolol in one, testosterone in seven and testosterone esters in four of them. A retrospective analysis of suspected compounds not included at the beginning of the method development was also possible by means of the full acquisition spectra obtained with the HRMS technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nutritional supplements cross-contaminated and faked with doping substances
Geyer, H., Parr, M. K., Koehler, K., Mareck, U., Schänzer, W., & Thevis, M. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1452 · Cited by 375 · cited 2×
“Thus, the spread of supplements, also coming from the black market, has increased dramatically in the last decades (Geyer et al. 2004, 2008; Baume et al. 2006; Parr et al. 2008).”
Background(2004) · International Journal of Sports Medicine · doi:10.1055/s-2004-819955 · Cited by 344
Nutritional supplements as a source for positive doping cases?
Kamber, M., Baume, N., Saugy, M., & Rivier, L. (2001) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.11.2.258 · Cited by 105 · cited 4×
“The subsequent detection step of AASs is mostly performed by GC-MS (Kamber et al. 2001; Delbeke et al. 2002; Geyer et al. 2004; Baume et al. *Corresponding author.”
BackgroundMethodInfluential
Cited by
Adulteration of Dietary Supplements by the Illegal Addition of Synthetic Drugs: A Review
Rocha, T., Amaral, J. S., & Oliveira, M. B. P. P. (2016) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12173 · Cited by 252
Mechanisms and Health Aspects of Food Adulteration: A Comprehensive Review
Momtaz, M., Bubli, S. Y., & Khan, M. S. (2023) · Foods · doi:10.3390/foods12010199 · Cited by 192
Hines, J. M., Bancos, I., Bancos, C., Singh, R. D., Avula, A. V., Young, W. F., Grebe, S. K., & Singh, R. J. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2017.271106 · Cited by 111
Neves, D. B. D. J., & Caldas, E. D. (2017) · Forensic Science International · doi:10.1016/j.forsciint.2017.03.016 · Cited by 71
Micalizzi, G., Huszti, K., Pálinkás, Z., Mandolfino, F., Martos, É., Dugo, P., Mondello, L., & Utczás, M. (2021) · Drug Testing and Analysis · doi:10.1002/dta.2929 · Cited by 16
Metadata
- Authors
- Odoardi, S., Castrignanò, E., Martello, S., Chiarotti, M., & Strano-Rossi, S.
- Venue
- Food Additives & Contaminants: Part A
- Publisher
- Informa UK Limited
- Published
- 2015-03-04
- Volume
- 32
- Issue
- 5
- Pages
- 1-13
- ISSN
- 1944-0049 (ISSN-L)
- 1944-0057
- OpenAlex
- W2090254429
- Cited by
- 40
- References
- 3
- FWCI
- 18.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of anabolic agents in dietary supplements by liquid chromatography-high-resolution mass spectrometry. https://app.cochat.ai/papers/10.1080/19440049.2015.1014868
- The paper
- Odoardi, S., Castrignanò, E., Martello, S., Chiarotti, M., & Strano-Rossi, S. (2015). Determination of anabolic agents in dietary supplements by liquid chromatography-high-resolution mass spectrometry. Food Additives & Contaminants: Part A. https://doi.org/10.1080/19440049.2015.1014868
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.