Slow sand filtration for water and wastewater treatment – a review
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Water pollution is a serious global issue. Various technologically advanced treatment methodologies, for example, activated sludge process, upflow anaerobic sludge blanket, membrane bioreactor, trickling filter, rotating biological contractor, oxidation ditch, are widely studied, well documented and adopted in practice. However, attention to promising low-investment-cost technologies, such as slow sand filtration (SSF) techniques, is surprisingly miniscule. SSF (at a flow rate of 0.1–0.2 m3/h) is quite effective water treatment technology. It is also efficient in removing coliform microorganisms such as Giardia, Cryptosporidium, Salmonella, Escherichia coli, total coliform (TC) and fecal coliform, fecal streptococci, bacteriophage, MS2 virus from water/wastewater. Apart from reduction of pathogenic load, which is ascribed to the biological processes, SSF can efficiently remove turbidity, suspended solids and toxic metals in treated water. The SSF treated effluent conforms to the discharge standards for potable (drinking) and/or non-potable (such as irrigation) uses. The paper reviews the basic mechanism, design criteria for achieving the best treatment efficiencies in SSF, along with its potential application areas. Further research is, however, needed to focus upon the composition and characteristics of schmutzdecke layer at molecular level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Co-selection of antibiotic and metal resistance
Baker-Austin, C., Wright, M. S., Stepanauskas, R., & McArthur, J. V. (2006) · Trends in Microbiology · doi:10.1016/j.tim.2006.02.006 · Cited by 1,883 · cited 1×
“However, microbial communities, on exposure to high metal concentrations may become resistant to them, and might have serious health repercussions [111].”
BackgroundWater Reuse: Issues, Technologies, and Applications
Asano, T. (2007) · Cited by 867
Novel biofiltration methods for the treatment of heavy metals from industrial wastewater
Srivastava, N. K., & Majumder, C. B. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.09.101 · Cited by 795 · cited 1×
“6; specific gravity, <5) [100] can be classified as essential or nonessential, depending on their need for performing vital physiological and biochemical functions.”
BackgroundHuisman, L., & Wood, W. E. (1974) · Medical Entomology and Zoology · Cited by 540
Membrane Separation Bioreactors for Wastewater Treatment
Visvanathan, C., Aim, R. B., & Parameshwaran, K. (2000) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643380091184165 · Cited by 499
KATSOYIANNIS, I., & ZOUBOULIS, A. (2002) · Water Research · doi:10.1016/s0043-1354(02)00236-1 · Cited by 442
Adsorption of As(III) from aqueous solutions by iron oxide-coated sand
Gupta, V. K., Saini, V. K., & Jain, N. (2005) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2005.02.054 · Cited by 389
A review on hydrolytic enzymes in the treatment of wastewater with high oil and grease content
Cammarota, M. C., & Freire, D. M. G. (2006) · Bioresource Technology · doi:10.1016/j.biortech.2006.02.030 · Cited by 357 · cited 1×
“Build-up of suspended solids (SS) and formation of biofilm on the media surface contributes for clogging [66,67].”
BackgroundArsenic(V) removal with a Ce(IV)-doped iron oxide adsorbent
Zhang, Y., Yang, M., & Huang, X. (2003) · Chemosphere · doi:10.1016/s0045-6535(02)00850-0 · Cited by 266 · cited 1×
“5 [104] Arsenic (As V) 100 [104] Arsenic (As III) 94–99 [105] Arsenic (As III) 59–79 [80] Arsenic (As V) 96–100 [80] Diclofenac 41 [34] Propranolol 94 [34] Iopromide 58 [34] ssIohexol 57 [34] Iomeprol 85 [34] Tebuconazole 59 [34] Propiconazole 21 [34] Copper 99.”
Matamoros, V., Arias, C., Brix, H., & Bayona, J. M. (2009) · Water Research · doi:10.1016/j.watres.2008.10.005 · Cited by 231
Elliott, M. A., Stauber, C. E., Koksal, F., DiGiano, F. A., & Sobsey, M. D. (2008) · Water Research · doi:10.1016/j.watres.2008.01.016 · Cited by 225 · cited 9×
“An intermittently operated household scale SSF (or BSF) could remove pathogens up to 4-log10 [46].”
BackgroundMethodInfluentialA method for preparing silica-containing iron(III) oxide adsorbents for arsenic removal
Zeng, L. (2003) · Water Research · doi:10.1016/s0043-1354(03)00402-0 · Cited by 219
Treatment of dairy wastewater using constructed wetlands and intermittent sand filters
Healy, M. G., Rodgers, M., & Mulqueen, J. (2007) · Bioresource Technology · doi:10.1016/j.biortech.2006.07.036 · Cited by 216
Berg, M., Luzi, S., Trang, P. T. K., Viet, P. H., Giger, W., & Stüben, D. (2006) · Environmental Science & Technology · doi:10.1021/es060144z · Cited by 211
Novel adsorbent based on silkworm chrysalides for removal of heavy metals from wastewaters
Paulino, A. T., Minasse, F. A. S., Guilherme, M. R., Reis, A. V., Muniz, E. C., & Nozaki, J. (2006) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2006.05.032 · Cited by 201
Biomass development in slow sand filters
Campos, L. C., Su, M. F. J., Graham, N. J. D., & Smith, S. R. (2002) · Water Research · doi:10.1016/s0043-1354(02)00167-7 · Cited by 183 · cited 2×
“[55] reported similar removal rates of organic carbon in them.”
BackgroundElimination of viruses, bacteria and protozoan oocysts by slow sand filtration
Hijnen, W. A. M., Schijven, J. F., Bonné, P. A. C., Visser, A., & Medema, G. J. (2004) · Water Science & Technology · doi:10.2166/wst.2004.0044 · Cited by 159
Biological denitrification of drinking water in a slow sand filter
Aslan, Ş., & Cakici, H. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.02.012 · Cited by 133 · cited 2×
“Nitrate-nitrogen removal efficiency has been shown to be 94% in a study of Aslan and Cakici with SSF [50].”
BackgroundCasas, M. E., & Bester, K. (2014) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2014.10.113 · Cited by 126 · cited 4×
“5 [104] Arsenic (As V) 100 [104] Arsenic (As III) 94–99 [105] Arsenic (As III) 59–79 [80] Arsenic (As V) 96–100 [80] Diclofenac 41 [34] Propranolol 94 [34] Iopromide 58 [34] ssIohexol 57 [34] Iomeprol 85 [34] Tebuconazole 59 [34] Propiconazole 21 [34] Copper 99.”
BackgroundResultInfluentialAnalysis of Bacterial Deposition on Metal (Hydr)oxide-Coated Sand Filter Media
Truesdail, S. E., Lukasik, J., Farrah, S. R., Shah, D. O., & Dickinson, R. B. (1998) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5541 · Cited by 121 · cited 1×
“Hydrophobic interactions, hydration and Van der Waals forces, surface roughness and bridging at the macromolecular level are the possible mechanistic factors responsible for bacterial adhesion [97,113].”
BackgroundEllis, K. V., & Wood, W. E. (1985) · Critical Reviews in Environmental Control · doi:10.1080/10643388509381736 · Cited by 115
Removal of As(V) and As(III) by reclaimed iron-oxide coated sands
Hsu, J.-C., Lin, C.-J., Liao, C., & Chen, S. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.09.031 · Cited by 115 · cited 3×
“Modifications in sand (coating of metal on sand) improve the turbidity removal efficiency [80].”
BackgroundCasas, M. E., Chhetri, R. K., Ooi, G. T. H., Hansen, K. M. S., Litty, K., Christensson, M., Kragelund, C., Andersen, H. R., & Bester, K. (2015) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2015.05.099 · Cited by 114 · cited 1×
“Removal of iopromide (31%) is observed to be highest amongst all pharmaceuticals when treated with moving bed biofilm reactor [99].”
BackgroundToxicant and parasite challenge of Manz intermittent slow sand filter
Palmateer, G., Manz, D. H., Jurkovic, A. A., McInnis, R., Unger, S., Kwan, K. K., & Dutka, B. J. (1999) · Environmental Toxicology · Cited by 110 · cited 1×
“Also, air saturated flow increases the pathogen removal efficiency by enhancing the air-water interface throughout column [90,91].”
BackgroundThe contents of Pb, Cu, Zn and Cd in meat in Nairobi, Kenya
Oyaro, N. M., Juddy, O., Murago, E. N. M., & Gitonga, E. (2007) · Journal of Food Agriculture & Environment · Cited by 107
Ahammed, M. M., & Davra, K. (2011) · Desalination · doi:10.1016/j.desal.2011.03.065 · Cited by 107 · cited 6×
“In a study done by Ahammed and Davra [30], iron-oxide coated sand was placed in between the 40-cm sand layer and resulted in improved removals of E.”
BackgroundInfluentialNitzsche, K. S., Weigold, P., Lösekann, T., Kappler, A. A., & Behrens, S. (2015) · Chemosphere · doi:10.1016/j.chemosphere.2015.05.032 · Cited by 106 · cited 2×
“Nitrifying microorganisms are known to be the dominating microbial community population on the household sand filter, along with archaeal diversity [86].”
BackgroundSurface Clogging in an Intermittent Stratified Sand Filter
Rodgers, M., Mulqueen, J., & Healy, M. G. (2004) · Soil Science Society of America Journal · doi:10.2136/sssaj2004.1827 · Cited by 104
Intermittent versus continuous operation of biosand filters
Young-Rojanschi, C., & Madramootoo, C. A. (2013) · Water Research · doi:10.1016/j.watres.2013.11.011 · Cited by 101 · cited 3×
“A diffuser plate drilled with 2 mm diameter holes may be placed 2 cm above the standing head [27,33] for homogenous supply of wastewater and to avoid disturbance to the schmutzdecke layer.”
BackgroundRemoving Giardia and Cryptosporidium by Slow Sand Filtration
Fogel, D., Isaac‐Renton, J. L., Guasparini, R., Moorehead, W., & Ongerth, J. E. (1993) · American Water Works Association · doi:10.1002/j.1551-8833.1993.tb06105.x · Cited by 89 · cited 1×
“SSF also has the potential of removing cysts of Giardia and Cryptosporidium enteroparasites [17,48,49].”
BackgroundNeto, R. F. M., Calijuri, M. L., Carvalho, I. D. C., & Santiago, A. D. F. (2012) · Resources Conservation and Recycling · doi:10.1016/j.resconrec.2012.06.001 · Cited by 89 · cited 3×
“The polyvinyl chloride (PVC) piping [20,24,25], perspex tube [10,26], transparent polypropylene [27], or a fiber glass [14] can be used as construction material for SSF column (Table 1).”
BackgroundMethodGrey water treatment in urban slums by a filtration system: Optimisation of the filtration medium
Katukiza, A. Y., Ronteltap, M., Niwagaba, C. B., Kansiime, F., & Lens, P. N. L. (2014) · Journal of Environmental Management · doi:10.1016/j.jenvman.2014.07.033 · Cited by 83 · cited 7×
“[32] studied the treatment of gray water in SSF using lava, sand and gravel as media.”
BackgroundMethodInfluentialVirus attenuation by microbial mechanisms during the idle time of a household slow sand filter
Ellıott, M., DiGiano, F. A., & Sobsey, M. D. (2011) · Water Research · doi:10.1016/j.watres.2011.05.008 · Cited by 80 · cited 10×
“Production of microbial extracellular products such as proteolytic enzymes or grazing of bacteria and higher microorganisms on virus particles are the plausible mechanism behind reduction of virus in SSF [27].”
BackgroundInfluentialFormation and fate of haloacetic acids (HAAs) within the water treatment plant
Rodríguez, M. J., Sérodes, J. B., & Roy, D. (2007) · Water Research · doi:10.1016/j.watres.2007.05.048 · Cited by 79 · cited 1×
“HAA biodegradation and decrease in DBP formation have been observed in SSF process [60].”
BackgroundArsenic Removal from Groundwater by Iron Impregnated Sand
Vaishya, R. C., & Gupta, S. K. (2002) · Journal of Environmental Engineering · doi:10.1061/(asce)0733-9372(2003)129:1(89 · Cited by 72 · cited 1×
“5 [104] Arsenic (As V) 100 [104] Arsenic (As III) 94–99 [105] Arsenic (As III) 59–79 [80] Arsenic (As V) 96–100 [80] Diclofenac 41 [34] Propranolol 94 [34] Iopromide 58 [34] ssIohexol 57 [34] Iomeprol 85 [34] Tebuconazole 59 [34] Propiconazole 21 [34] Copper 99.”
Treatment of municipal wastewater using laterite-based constructed soil filter
Kadam, A. M., Nemade, P. D., Oza, G., & Shankar, H. S. (2009) · Ecological Engineering · doi:10.1016/j.ecoleng.2009.03.008 · Cited by 71
Modeling Arsenic(V) Removal from Water by Sulfate Modified Iron‐Oxide Coated Sand (SMIOCS)
Vaishya, R. C., & Gupta, S. K. (2004) · Separation Science and Technology · doi:10.1081/ss-120027999 · Cited by 67
Removal of dissolved organic carbon and nitrogen during simulated soil aquifer treatment
Essandoh, H. M. K., Tizaoui, C., & Mohamed, M. H. A. (2013) · Water Research · doi:10.1016/j.watres.2013.04.013 · Cited by 50
Transport of nanoparticles with dispersant through biofilm coated drinking water sand filters
Li, Z., Hassan, A. A., Sahle‐Demessie, E., & Sorial, G. A. (2013) · Water Research · doi:10.1016/j.watres.2013.08.026 · Cited by 48 · cited 1×
“Peristaltic pump may also be used to maintain the pressure [22].”
MethodRemoval of oil and oil sheen from produced water by pressure-assisted ozonation and sand filtration
Cha, Z., Lin, C., Cheng, C.-J., & Hong, P. K. A. (2009) · Chemosphere · doi:10.1016/j.chemosphere.2009.10.051 · Cited by 44 · cited 1×
“However, up to 99% turbidity removal can be achieved when SSF is used in combination with other techniques such as pressure-assisted ozonation [28].”
Keraita, B., Drechsel, P., Konradsen, F., & Vreugdenhil, R. C. (2008) · Journal of Environmental Science and Health, Part A · doi:10.1080/10934520801959948 · Cited by 36
Welz, P. J., & Roes‐Hill, M. L. (2014) · Journal of Water Process Engineering · doi:10.1016/j.jwpe.2014.06.007 · Cited by 19 · cited 1×
“COD removal efficiencies by SSF are reported to be in between 70% and 80% [10,81].”
BackgroundBiological processes and organic micropollutants in treatment processes
Rittmann, B. E. (1985) · The Science of The Total Environment · doi:10.1016/0048-9697(85)90322-5 · Cited by 11
Aluminum Oxide-Coated Sand for Improved Treatment of Urban Stormwater
Johannsen, L. L., Cederkvist, K., Holm, P. E., & Ingvertsen, S. T. (2016) · Journal of Environmental Quality · doi:10.2134/jeq2015.06.0287 · Cited by 8
Cited by
Biological remediation technologies for dyes and heavy metals in wastewater treatment: New insight
Singh, A., Pal, D. B., Mohammad, A., Alhazmi, A., Haque, S., Yoon, T., Srivastava, N., & Gupta, V. K. (2022) · Bioresource Technology · doi:10.1016/j.biortech.2021.126154 · Cited by 466
A review on halloysite-based adsorbents to remove pollutants in water and wastewater
Anastopoulos, I., Mittal, A., Usman, M., Mittal, J., Yu, G., Núñez-Delgado, A., & Kornaros, M. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.08.104 · Cited by 222
Owodunni, A. A., & Ismail, S. (2021) · Journal of Water Process Engineering · doi:10.1016/j.jwpe.2021.102096 · Cited by 185
Recent advances in hydrochar application for the adsorptive removal of wastewater pollutants
Ighalo, J. O., Rangabhashiyam, S., Dulta, K., Umeh, C. T., Iwuozor, K. O., Aniagor, C. O., Eshiemogie, S. O., Iwuchukwu, F. U., & Igwegbe, C. A. (2022) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2022.06.028 · Cited by 174
Insights into the Domestic Wastewater Treatment (DWWT) Regimes: A Review
Koul, B., Yadav, D., Singh, S., Kumar, M., & Song, M. (2022) · Water · doi:10.3390/w14213542 · Cited by 174
Metadata
- Authors
- Verma, S., Daverey, A., & Sharma, A.
- Venue
- Environmental Technology Reviews
- Publisher
- Informa UK Limited
- Published
- 2017-01
- Volume
- 6
- Issue
- 1
- Pages
- 47-58
- ISSN
- 2162-2515 (ISSN-L)
- 2162-2523
- OpenAlex
- W2581636506
- Cited by
- 182
- References
- 44
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.