Evaluating Indoor Air Quality and Energy Impacts of Ventilation in a Net-Zero Energy House Using a Coupled Model
Open accessAbstract
The National Institute of Standards and Technology constructed the Net-Zero Energy (NZE) Residential Test Facility to support the development and adoption of cost-effective NZE designs and technologies. In support of indoor air quality goals, contaminant source control approaches were implemented that minimized the use of products containing urea-formaldehyde resin and utilized products with relatively low volatile organic compound emissions. Indoor and outdoor concentrations of formaldehyde and acetaldehyde were measured approximately monthly for 15 months. Independent emission measurements of formaldehyde were made in a small chamber system to determine the emission rates from samples of the wood flooring, plywood, and wood cabinetry taken from the house. Blower door tests were performed to determine the leakage area of the exterior envelope, the interior floors, and transfer grilles between floors. Real-time formaldehyde concentration and energy measurements were used to verify the indoor concentrations and energy predictions of a coupled CONTAM-EnergyPlus model of the house. The verified model was then used to evaluate the impacts of different outdoor air ventilation rates on indoor concentrations and energy. This work demonstrates the need for consideration of source control options during product selection and the provision of mechanical ventilation, especially in homes with relatively airtight envelopes.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Recirculated indoor air may convey an excessive level of CO2.
“as recirculated indoor air may convey an excessive level of CO2 [5].”
From A Microalgae Photobioreactor System for Indoor Air Remediation: Empirical Examination of the CO2 Absorption Performance of Spirulina maxima in a NaHCO3-Reduced Medium (2023) · cites this paper as [5]
The Introduction says the study modeled formaldehyde and acetaldehyde, and the Conclusion says lower outdoor-air ventilation can increase indoor contaminants. Neither passage addresses excessive CO2 conveyed by recirculated air; searches for CO2, carbon dioxide, and recirculation found no passage establishing that point. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808 · see citing works
Formaldehyde, 2-butoxyethanol and 1-tert-butoxypropan-2-ol.
(2006) · PubMed Central · Cited by 505 · see citing works
Co-simulation of building energy and control systems with the Building Controls Virtual Test Bed
Wetter, M. (2010) · Journal of Building Performance Simulation · doi:10.1080/19401493.2010.518631 · Cited by 457 · see citing works
Re-evaluation of some organic chemicals, hydrazine and hydrogen peroxide.
(1999) · PubMed Central · Cited by 334 · see citing works
Influence of temperature on formaldehyde emission parameters of dry building materials
Zhang, Y., Luo, X., Wang, X., Qian, K., & Zhao, R. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.10.081 · Cited by 194 · see citing works
A Common Definition for Zero Energy Buildings
Peterson, K., Torcellini, P., & Grant, R. (2015) · doi:10.2172/1884396 · Cited by 156 · see citing works
Xiong, J., Zhang, P., Huang, S., & Zhang, Y. (2016) · Environmental Research · doi:10.1016/j.envres.2016.09.003 · Cited by 125 · see citing works
Energy Performance of Buildings Directive
(2005) · International Journal of Building Pathology and Adaptation · doi:10.1108/ss.2005.11023aab.001 · Cited by 120 · see citing works
Dols, W. S., Emmerich, S. J., & Polidoro, B. J. (2016) · Building Simulation · doi:10.1007/s12273-016-0279-2 · Cited by 114 · see citing works
Self-citationVentilation and indoor air quality in new homes
Crump, D., Dimitroulopoulou, S., Squire, R. W., Ross, D., Pierce, B., White, M., Brown, V. M., & Coward, S. (2005) · Pollution atmosphérique · Cited by 97 · see citing works
Hult, E. L., Willem, H., Price, P. N., Hotchi, T., Russell, M. L., & Singer, B. C. (2014) · Indoor Air · doi:10.1111/ina.12160 · Cited by 86 · see citing works
Net-zero and beyond! Design and performance of NIST's net-zero energy residential test facility
Fanney, A. H., Payne, V., Ullah, T., Ng, L. C., Boyd, M. T., Omar, F., Davis, M. W., Skye, H. M., Dougherty, B. P., Polidoro, B. J., et al. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.05.002 · Cited by 64 · see citing works
Self-citationDols, W. S., Emmerich, S. J., & Polidoro, B. J. (2015) · Building Services Engineering Research and Technology · doi:10.1177/0143624415619464 · Cited by 47 · see citing works
Self-citationPoppendieck, D. G., Ng, L. C., Persily, A. K., & Hodgson, A. T. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.07.001 · Cited by 43 · see citing works
Self-citationMethods and results of characterization of organic emissions from an indoor material
Sanchez, D. C., Mason, M., & Norris, C. (1987) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(87)90010-2 · Cited by 40 · see citing works
Design Challenges of the NIST Net Zero Energy Residential Test Facility
Healy, W. M., Gates, C., Fanney, A. H., & Pettit, B. (2015) · doi:10.6028/nist.tn.1847 · Cited by 37 · see citing works
Silberstein, S., Grot, R. A., Ishiguro, K., & Mulligan, J. L. (1988) · JAPCA · doi:10.1080/08940630.1988.10466480 · Cited by 27 · see citing works
Performance Data from the NIST Net-Zero Energy Residential Test Facility
Healy, W. M., Fanney, A. H., Dougherty, B. P., Ng, L. C., Payne, V., Ullah, T., & Omar, F. (2017) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.122.014 · Cited by 25 · see citing works
Self-citationMeasurement of organic compound emission using small test chambers
Tichenor, B. A. (1989) · Environment International · doi:10.1016/0160-4120(89)90053-6 · Cited by 21 · see citing works
Indoor air quality in high-performing building case studies: Got data?
Teichman, K. Y., Persily, A. K., & Emmerich, S. J. (2015) · Science and Technology for the Built Environment · doi:10.1080/10789669.2014.976509 · Cited by 12 · see citing works
Self-citationFormaldehyde Concentrations in a Net-Zero Energy House: Real-time Monitoring and Simulation.
Poppendieck, D. G., Khurshid, S. S., Dols, W. S., Ng, L. C., Polidoro, B. J., & Emmerich, S. J. (2016) · PubMed · Cited by 9 · see citing works
Self-citationKneifel, J. D. (2015) · doi:10.6028/nist.sp.1182 · Cited by 7 · see citing works
Grot, R. A., Silberstein, S., & Ishiguro, K. (1985) · doi:10.6028/nbs.ir.85-3255 · Cited by 4 · see citing works
High Performance Indoor Air Quality Specification for Net Zero Energy Homes
Dean, B., & GreenSpec, W. (2015) · doi:10.6028/nist.gcr.14-980 · Cited by 3 · see citing works
Chairman's summary, session II
Mølhave, L. (1987) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(87)90006-0 · Cited by 2 · see citing works
Flagged first, then by citations
1 of the 26 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Ng L Persily A Emmerich S 2015 Infiltration and Ventilation in a Very Tight, High Performance Home 36th AIVC Conference Effective Ventilation in High Performance Buildings Madrid, Spain
Cited by
Sorted by citations
Residential net-zero energy buildings: Review and perspective
Wu, W., & Skye, H. M. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110859 · Cited by 391 · see citing works
Jiang, J., Jung, N., & Boor, B. E. (2021) · ACS ES&T Engineering · doi:10.1021/acsestengg.1c00002 · Cited by 23 · see citing works
Wang, Y., Petrou, G., Symonds, P., Hsu, S.-C., Milner, J., Hutchinson, E. J., Davies, M., & Macintyre, H. L. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.111794 · Cited by 19 · see citing works
Estimating real-time infiltration for use in residential ventilation control
Ng, L. C., Zimmerman, S. M., Good, J., Toll, B., Emmerich, S. J., & Persily, A. K. (2019) · Indoor and Built Environment · doi:10.1177/1420326x19870229 · Cited by 19 · see citing works
Self-citationHan, M., Park, J., Kim, I., & Yi, H. (2023) · Applied Sciences · doi:10.3390/app132412991 · Cited by 11 · see citing works
Airflow and indoor air quality models of DOE prototype commercial buildings
Ng, L. C., Musser, A., Persily, A. K., & Emmerich, S. J. (2019) · doi:10.6028/nist.tn.2072 · Cited by 10 · see citing works
Self-citationGuyot, G., Geoffroy, H., Ondarts, M., Migne, L., Bobee, M., Gonze, E., & Woloszyn, M. (2019) · Building Simulation · doi:10.1007/s12273-019-0557-x · Cited by 9 · see citing works
Martín-Davison, J. S., Scott, F., Vergara‐Ojeda, C., Moreno‐Casas, P. A., Hort, C., & Vergara-Fernández, A. O. (2023) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.7533 · Cited by 5 · see citing works
IAQ 2016: Defining indoor air quality: Policy, standards and best practices
Bahnfleth, W. P., & Sekhar, C. (2017) · Science and Technology for the Built Environment · doi:10.1080/23744731.2017.1417068 · Cited by 2 · see citing works
Spencer‐Williams, I., Engelmeier, J., & Haig, S. (2025) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2025.179710 · Cited by 1 · see citing works
Estimating Interzonal Leakage in a Net-Zero Energy House
Ng, L. C., Kinser, L., Emmerich, S. J., & Persily, A. K. (2019) · ASTM International eBooks · doi:10.1520/stp161520180020 · Cited by 1 · see citing works
Self-citationEarly-stage concentrations of formaldehydes and TVOCs in a new low-energy building
Kalagasidis, A. S., Domhagen, F., & Langer, S. (2020) · E3S Web of Conferences · doi:10.1051/e3sconf/202017206007 · Cited by 1 · see citing works
Balancing Energy and IAQ: NIST Net-Zero Energy Residential Test Facility.
Ng, L. C., Poppendieck, D. G., Dols, W. S., Dougherty, B. P., & Emmerich, S. J. (2018) · PubMed
Self-citationRasli, N. B. I., Ramli, N. A., & Ismail, M. R. (2021) · Current World Environment · doi:10.12944/cwe.16.3.11
Estimating real-time infiltration for use in residential ventilation control
Ng, L. F. P., Zimmerman, S., Good, J., Toll, B., Emmerich, S. J., & Persily, A. K. (2019) · doi:10.6028/nist.tn.2046
Self-citationWilliams, I. S., Engelmeier, J., & Haig, S. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4837030
- Authors
- Ng, L., Poppendieck, D., Dols, W. S., & Emmerich, S. J.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Ng, Lisa
- Venue
- Science and Technology for the Built Environment
- Publisher
- Informa UK Limited
- Published
- 2017-11-30
- Volume
- 24
- Issue
- 2
- Pages
- 124-134
- ISSN
- 1078-9669 (ISSN-L)
- 2374-4731
- 2374-474X
- PMC
- PMC6506835
- OpenAlex
- W2771374661
- Cited by
- 16
- References
- 26
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 2 · 2021: 3 · 2020: 1 · 2019: 5 · 2018: 1 · 2017: 1
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Science and Technology for the Built Environment (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Keywords
- net-zero energy house, indoor air quality, mechanical ventilation, formaldehyde, acetaldehyde, volatile organic compounds, source control, urea-formaldehyde resin, blower door testing, air leakage, coupled simulation model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review