Steerable catheters for minimally invasive surgery: a review and future directions
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
The steerable catheter refers to the catheter that is manipulated by a mechanism which may be driven by operators or by actuators. The steerable catheter for minimally invasive surgery has rapidly become a rich and diverse area of research. Many important achievements in design, application and analysis of the steerable catheter have been made in the past decade. This paper aims to provide an overview of the state of arts of steerable catheters. Steerable catheters are classified into four main groups based on the actuation principle: (1) tendon driven catheters, (2) magnetic navigation catheters, (3) soft material driven catheters (shape memory effect catheters, steerable needles, concentric tubes, conducting polymer driven catheters and hydraulic pressure driven catheters), and (4) hybrid actuation catheters. The advantages and limitations of each of them are commented and discussed in this paper. The future directions of research are summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bathe, K. (1995) · CERN Document Server (European Organization for Nuclear Research) · Cited by 10,651
A Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Nonlinear Continuum Mechanics for Finite Element Analysis
Bonet, J., & Wood, R. D. (2008) · doi:10.1017/cbo9780511755446 · Cited by 1,824
Nonlinear Problems of Elasticity
(2005) · Applied Mathematical Sciences · doi:10.1007/0-387-27649-1 · Cited by 1,670
An overview of nitinol medical applications
Duerig, T., Pelton, A., & Stöckel, D. (1999) · Materials Science and Engineering: A · doi:10.1016/s0921-5093(99)00294-4 · Cited by 1,628 · cited 9×
“For the MIS surgery, the small diameter of the catheter is one of the basic requirements.”
BackgroundInfluentialConjugated Polymer Actuators for Biomedical Applications
Smela, E. (2003) · Advanced Materials · doi:10.1002/adma.200390113 · Cited by 1,177 · cited 1×
“The advantage of the EAP tip of the catheter includes: (1) low voltate (under 2 V) and (2) ease with miniaturization [96].”
BackgroundNonlinear Problems of Elasticity
Antman, S. S. (1995) · Applied Mathematical Sciences · doi:10.1007/978-1-4757-4147-6 · Cited by 1,098
Medical shape memory alloy applications—the market and its products
Morgan, N. B. (2004) · Materials Science and Engineering: A · doi:10.1016/j.msea.2003.10.326 · Cited by 838 · cited 9×
“For the MIS surgery, the small diameter of the catheter is one of the basic requirements.”
BackgroundInfluentialHannan, M. W., & Walker, I. D. (2003) · Journal of Robotic Systems · doi:10.1002/rob.10070 · Cited by 737
Cited by
Xavier, M. S., Tawk, C. D., Zolfagharian, A., Pinskier, J., Howard, D., Young, T., Lai, J., Harrison, S. M., Yong, Y. K., Bodaghi, M., et al. (2022) · IEEE Access · doi:10.1109/access.2022.3179589 · Cited by 418
Finite Element Modeling of Soft Fluidic Actuators: Overview and Recent Developments
Xavier, M. S., Fleming, A. J., & Yong, Y. K. (2021) · Advanced Intelligent Systems · doi:10.1002/aisy.202000187 · Cited by 313
Challenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Metadata
- Authors
- Hu, X., Chen, A., Luo, Y., Zhang, C., & Zhang, E.
- Venue
- Computer Assisted Surgery
- Publisher
- Informa UK Limited
- Published
- 2018-01
- Volume
- 23
- Issue
- 1
- Pages
- 21-41
- ISSN
- 2469-9322 (ISSN-L)
- OpenAlex
- W2903348871
- Cited by
- 184
- References
- 62
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.