Steerable catheters for minimally invasive surgery: a review and future directions
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
The steerable catheter refers to the catheter that is manipulated by a mechanism which may be driven by operators or by actuators. The steerable catheter for minimally invasive surgery has rapidly become a rich and diverse area of research. Many important achievements in design, application and analysis of the steerable catheter have been made in the past decade. This paper aims to provide an overview of the state of arts of steerable catheters. Steerable catheters are classified into four main groups based on the actuation principle: (1) tendon driven catheters, (2) magnetic navigation catheters, (3) soft material driven catheters (shape memory effect catheters, steerable needles, concentric tubes, conducting polymer driven catheters and hydraulic pressure driven catheters), and (4) hybrid actuation catheters. The advantages and limitations of each of them are commented and discussed in this paper. The future directions of research are summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bathe, K. (1995) · CERN Document Server (European Organization for Nuclear Research) · Cited by 10,651
A Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Nonlinear Continuum Mechanics for Finite Element Analysis
Bonet, J., & Wood, R. D. (2008) · doi:10.1017/cbo9780511755446 · Cited by 1,824
Nonlinear Problems of Elasticity
(2005) · Applied Mathematical Sciences · doi:10.1007/0-387-27649-1 · Cited by 1,670
An overview of nitinol medical applications
Duerig, T., Pelton, A., & Stöckel, D. (1999) · Materials Science and Engineering: A · doi:10.1016/s0921-5093(99)00294-4 · Cited by 1,628 · cited 9×
“For the MIS surgery, the small diameter of the catheter is one of the basic requirements.”
BackgroundInfluentialConjugated Polymer Actuators for Biomedical Applications
Smela, E. (2003) · Advanced Materials · doi:10.1002/adma.200390113 · Cited by 1,177 · cited 1×
“The advantage of the EAP tip of the catheter includes: (1) low voltate (under 2 V) and (2) ease with miniaturization [96].”
BackgroundNonlinear Problems of Elasticity
Antman, S. S. (1995) · Applied Mathematical Sciences · doi:10.1007/978-1-4757-4147-6 · Cited by 1,098
Medical shape memory alloy applications—the market and its products
Morgan, N. B. (2004) · Materials Science and Engineering: A · doi:10.1016/j.msea.2003.10.326 · Cited by 838 · cited 9×
“For the MIS surgery, the small diameter of the catheter is one of the basic requirements.”
BackgroundInfluentialHannan, M. W., & Walker, I. D. (2003) · Journal of Robotic Systems · doi:10.1002/rob.10070 · Cited by 737
Needle insertion into soft tissue: A survey
Abolhassani, N., Patel, R., & Moallem, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.003 · Cited by 704
Statics and Dynamics of Continuum Robots With General Tendon Routing and External Loading
Rucker, D. C., & Webster III, R. J. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2160469 · Cited by 669
Mechanics Modeling of Tendon-Driven Continuum Manipulators
Camarillo, D. B., Milne, C. F., Carlson, C. R., Zinn, M. R., & Salisbury, J. K. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2002311 · Cited by 655 · cited 1×
“The steerable catheter was developed by [43,49].”
Nonholonomic Modeling of Needle Steering
Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065388 · Cited by 633 · cited 2×
“directly interact with soft tissues [75,76], (Webster”
MethodContinuum robots - a state of the art
Robinson, G., & Davies, J. B. C. (2003) · Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C) · doi:10.1109/robot.1999.774029 · Cited by 619
Nonholonomic Modeling of Needle Steering
Webster, R. J., Cowan, N. J., Chirikjian, G., & Okamura, A. M. (2006) · Springer Tracts in Advanced Robotics · doi:10.1007/11552246_4 · Cited by 527
A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots
Rucker, D. C., Jones, B. A., & Webster, R. J., III (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2062570 · Cited by 513
Mechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485 · cited 3×
“Reprinted with the permission from [85] # 2009 IEEE.”
BackgroundInfluentialContinuous Backbone “Continuum” Robot Manipulators
Walker, I. D. (2013) · ISRN Robotics · doi:10.5402/2013/726506 · Cited by 405
Robotic Magnetic Navigation for Atrial Fibrillation Ablation
Pappone, C., Vicedomini, G., Manguso, F., Gugliotta, F., Mazzone, P., Gulletta, S., Sora, N., Sala, S., Marzi, A., Augello, G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.058 · Cited by 402
Ernst, S., Ouyang, F., Linder, C., Hertting, K., Stahl, F., Chun, J., Hachiya, H., Bänsch, D., Antz, M., & Kuck, K.-H. (2004) · Circulation · doi:10.1161/01.cir.0000125126.83579.1b · Cited by 353 · cited 2×
“NiobeVR ES magnetic navigation system is designed to make the treatment of complex cardiac arrhythmias safe and effective (Figure 10) (Stereotaxis 2016), [54].”
BackgroundMethodA Telerobotic System for Transnasal Surgery
Burgner, J., Rucker, D. C., Gilbert, H. B., Swaney, P. J., Russell, P. T., Weaver, K. D., & Webster, R. J. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2265804 · Cited by 294
Novel, Magnetically Guided Catheter for Endocardial Mapping and Radiofrequency Catheter Ablation
Faddis, M. N., Blume, W., Finney, J., Hall, A., Rauch, J., Sell, J., Bae, K. T., Talcott, M., & Lindsay, B. (2002) · Circulation · doi:10.1161/01.cir.0000038704.84304.6f · Cited by 280 · cited 4×
“A delay occurs between designation of the magnetic field vector and catheter movement [61,63].”
BackgroundInfluentialStiffness Control of Surgical Continuum Manipulators
Mahvash, M., & Dupont, P. E. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2105410 · Cited by 265
Configuration Tracking for Continuum Manipulators With Coupled Tendon Drive
Camarillo, D. B., Carlson, C. R., & Salisbury, J. K. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2022426 · Cited by 237 · cited 1×
“In the distributed coupling of sections, the tendons for each section have their independent pathways; the examples can be found in [47,52,53].”
BackgroundEquilibrium Conformations of Concentric-tube Continuum Robots
Rucker, D. C., Webster, R. J., Chirikjian, G. S., & Cowan, N. J. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910367543 · Cited by 217
Towards flexible medical instruments: Review of flexible fluidic actuators
De Greef, A., Lambert, P., & Delchambre, A. (2009) · Precision Engineering · doi:10.1016/j.precisioneng.2008.10.004 · Cited by 204
Concentric Tube Robots: The State of the Art and Future Directions
Gilbert, H. B., Rucker, D. C., & Webster III, R. J. (2016) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-319-28872-7_15 · Cited by 197 · cited 1×
“A review of the state of arts of the device of the concentric tube robot can be found in [86].”
BackgroundMotion Planning Under Uncertainty for Image-guided Medical Needle Steering
Alterovitz, R., Branicky, M., & Goldberg, K. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364908097661 · Cited by 189 · cited 1×
“[78,79] developed a 2D planning algorithm for the insertion of a flexible needle with a beveled tip into soft tissues with obstacles.”
Kutzer, M. D. M., Segreti, S. M., Brown, C. Y., Armand, M., Taylor, R. H., & Mears, S. C. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5980285 · Cited by 162 · cited 4×
“Reprinted with the permission from [15] # 2011 IEEE.”
BackgroundInfluentialThree dimensional statics for continuum robotics
Jones, B. A., Gray, R. L., & Turlapati, K. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354199 · Cited by 154
Saliba, W. I., Cummings, J. E., Oh, S., Zhang, Y., Mazgalev, T. N., Schweikert, R. A., Burkhardt, J. D., & Natale, A. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00556.x · Cited by 138
Integrating Deflection Models and Image Feedback for Real-Time Flexible Needle Steering
Abayazid, M., Roesthuis, R. J., Reilink, R., & Misra, S. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2230991 · Cited by 138 · cited 1×
“[82] presented an ultrasound image guided control system to steer a flexible needle made from nitinol with an asymmetric tip.”
Alıcı, G., Mui, B., & Cook, C. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.10.020 · Cited by 131 · cited 1×
“[99] proposed a conducting polymer actuator, which has potential to be the bending of the tip of the steerable catheter.”
BackgroundBiase, L. D., Wang, Y., Horton, R., Gallinghouse, G. J., Mohanty, P. K., Sánchez, J., Patel, D., Dare, M., Canby, R. C., Price, L. D., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01570.x · Cited by 121 · cited 1×
“However, from other clinic feedbacks [2], the complications are not reduced with the Sensei X Robotic Catheter System, and the complications are even higher than manual operations.”
BackgroundThree-dimensional Motion Planning Algorithms for Steerable Needles Using Inverse Kinematics
Duindam, V., Xu, J., Alterovitz, R., Sastry, S., & Goldberg, K. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909352202 · Cited by 117 · cited 2×
“(2010) [81] Pre-bent concentric tube 3 5 N/A Co-placed General MIS 1.”
MethodA review of radiofrequency ablation: Large target tissue necrosis and mathematical modelling
Zhang, B., Moser, M., Zhang, E. M., Luo, Y., Liu, C., & Zhang, W. (2016) · Physica Medica · doi:10.1016/j.ejmp.2016.07.092 · Cited by 116 · cited 2×
“such as diagnosis and radiofrequency ablation (RFA) of tumors [44,45], there is no central open lumen (i.”
BackgroundSelf-citationSteerable Catheters in Cardiology: Classifying Steerability and Assessing Future Challenges
Ali, A., Plettenburg, D. H., & Breedveld, P. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2525785 · Cited by 101 · cited 1×
“[29] in several aspects: (1) the scope of applica-”
BackgroundPercutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools
Gosline, A. H., Vasilyev, N. V., Butler, E. J., Folk, C. R., Cohen, A., Chen, R., Lang, N., del Nido, P. J., & Dupont, P. E. (2012) · The International Journal of Robotics Research · doi:10.1177/0278364912443718 · Cited by 98
Evaluation of robotic endovascular catheters for arch vessel cannulation
Riga, C. V., Bicknell, C. D., Hamady, M., & Cheshire, N. J. W. (2011) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.03.218 · Cited by 92
Autonomous Image-Guided Robot-Assisted Active Catheter Insertion
Jayender, J., Azizian, M., & Patel, R. V. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2001353 · Cited by 89 · cited 2×
“[70,71] developed an catheter actuated by three SMA wires spaced at”
BackgroundMethodTang, W. J., Wan, T. R., Gould, D., How, T. V., & John, N. W. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2199319 · Cited by 85
Robot-assisted Active Catheter Insertion: Algorithms and Experiments
Jayender, J., Patel, R. V., & Nikumb, S. K. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909103785 · Cited by 84 · cited 3×
“[70,71] developed an catheter actuated by three SMA wires spaced at”
BackgroundMethodDesign theory and methodology for enterprise systems
Zhang, W., & Wang, J. (2016) · Enterprise Information Systems · doi:10.1080/17517575.2015.1080860 · Cited by 75
An integrated environment for CAD/CAM of mechanical systems
Zhang, W. (1994) · Research Repository (Delft University of Technology) · Cited by 75
Comparison, optimization, and limitations of magnetic manipulation systems
Erni, S., Schuerle, S., Fakhraee, A., Kratochvil, B. E., & Nelson, B. J. (2013) · Journal of Micro-Bio Robotics · doi:10.1007/s12213-013-0070-8 · Cited by 72 · cited 1×
“Indeed, the switching of the entire system (on and off) can easily be realized by the electromagnets [56,61,63].”
BackgroundChun, K. R. J., Wißner, E., Koektuerk, B., Konstantinidou, M., Schmidt, B., Zerm, T., Metzner, A., Tilz, R. R., Boczor, S., Fuernkranz, A., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.942672 · Cited by 66
Proietti, R., Pecoraro, V. L., Biase, L. D., Natale, A., Santangeli, P., Viecca, M., Sagone, A., Galli, A., Moja, L., & Tagliabue, L. (2013) · EP Europace · doi:10.1093/europace/eut058 · Cited by 65 · cited 2×
“It is worth to mention that some clinic feedbacks [54,59] have shown that the magnetic navigation catheter systems (Niobe systems in particular) were conducive to reducing the complication.”
BackgroundImpact of Remote Magnetic Catheter Navigation on Ablation Fluoroscopy and Procedure Time
Kim, A. M., Turakhia, M. P., Lu, J. T., Badhwar, N., Lee, B. K., Lee, R. J., Marcus, G. M., Tseng, Z. H., Scheinman, M. M., & Olgin, J. E. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01202.x · Cited by 65
Rama, D. F., Estrada, A., Shachar, J., Castrejón, S. C., Doiny, D., Ortega, M., Gang, E. S., & Merino, J. L. (2013) · Journal of Visualized Experiments · doi:10.3791/3658 · Cited by 53
Wood, M. A., Orlov, M. V., Ramaswamy, K., Haffajee, C. I., Ellenbogen, K. A., & The Stereotaxis Heart Study Investigators (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01183.x · Cited by 53
Feasibility and Safety of Remote Endovascular Catheter Navigation in a Porcine Model
Bismuth, J. X., Kashef, E., Cheshire, N. J. W., & Lumsden, A. B. (2011) · Journal of Endovascular Therapy · doi:10.1583/10-3324r.1 · Cited by 50
Positioning system for catheter tips based on an active microvalve system
Ruzzu, A., Bade, K. J., Fahrenberg, J., & Maas, D. (1998) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/8/2/030 · Cited by 41
OVERVIEW OF UPCOMING ADVANCES IN COLONOSCOPY
Cheng, W., Moser, M., Kanagaratnam, S., & ZHANG, W. J. (2011) · Digestive Endoscopy · doi:10.1111/j.1443-1661.2011.01181.x · Cited by 39
Early Experience with Robotic Navigation for Catheter Ablation of Paroxysmal Atrial Fibrillation
Kautzner, J., Peichl, P., Cihak, R. J., Wichterle, D., & MLCOCHOVA, H. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02277.x · Cited by 38
Robotic navigation for catheter ablation: benefits and challenges
Aagaard, P., Natale, A., & Biase, L. D. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1052406 · Cited by 37
Modeling and In Vitro Experimental Validation for Kinetics of the Colonoscope in Colonoscopy
Cheng, W.-B., Di, Y., Zhang, E. M., Moser, M., Kanagaratnam, S., Korman, L. Y., Sarvazyan, N., & Zhang, W.-J. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0746-1 · Cited by 37 · cited 1×
“The entire system should be viewed as a human-machine (surgeon-catheter) system [19].”
BackgroundSelf-citationUllah, W., Hunter, R. J., Haldar, S., McLean, A., Dhinoja, M., Sporton, S. C., Earley, M. J., Lorgat, F., Wong, T., & SCHILLING, R. J. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12501 · Cited by 34
Design and Experimental Validation of an Active Catheter for Endovascular Navigation
Couture, T., & Szewczyk, J. (2017) · Journal of Medical Devices · doi:10.1115/1.4038334 · Cited by 29 · cited 4×
“Similar catheters for neuroradiology can be found in [13,72].”
BackgroundInfluentialKinematic characterization of a cardiac ablation catheter
Ganji, Y., & Janabi‐Sharifi, F. (2007) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2007.4399468 · Cited by 27
Tiba, A., & Culbertson, B. M. (1999) · Journal of Macromolecular Science Part A · doi:10.1081/ma-100101593 · Cited by 5 · cited 1×
“thermal, and biochemical) [28] and sterilizable; (5) The”
Modeling and Control of a Continuum Style Microrobot for Endovascular Surgery
Bailly, Y., Amirat, Y., & Fried, G. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2151350 · cited 4×
“(2011) [10] Hydraulic 1 2 90 N/A Aneurysm surgery 4.”
BackgroundInfluential
Cited by
Xavier, M. S., Tawk, C. D., Zolfagharian, A., Pinskier, J., Howard, D., Young, T., Lai, J., Harrison, S. M., Yong, Y. K., Bodaghi, M., et al. (2022) · IEEE Access · doi:10.1109/access.2022.3179589 · Cited by 418
Finite Element Modeling of Soft Fluidic Actuators: Overview and Recent Developments
Xavier, M. S., Fleming, A. J., & Yong, Y. K. (2021) · Advanced Intelligent Systems · doi:10.1002/aisy.202000187 · Cited by 313
Challenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Metadata
- Authors
- Hu, X., Chen, A., Luo, Y., Zhang, C., & Zhang, E.
- Venue
- Computer Assisted Surgery
- Publisher
- Informa UK Limited
- Published
- 2018-01
- Volume
- 23
- Issue
- 1
- Pages
- 21-41
- ISSN
- 2469-9322 (ISSN-L)
- OpenAlex
- W2903348871
- Cited by
- 184
- References
- 62
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.