The DOI matches its OpenAlex record.
Intrapartum sonography to determine fetal head position
Abstract
OBJECTIVE: To investigate the accuracy of intrapartum transvaginal digital examination in defining the position of the fetal head. PATIENTS AND METHODS: In 496 singleton pregnancies in labor at term, the fetal head position was determined by routine transvaginal digital examination by the attending midwife or obstetrician. Immediately before or after the clinical examination, the fetal head position was determined using transabdominal ultrasound by an appropriately trained sonographer who was not aware of the clinical findings. The digital examination was considered to be correct if the fetal head position was within 45 degrees of the ultrasound finding. The accuracy of the digital examination was examined in relation to maternal characteristics and the progress of labor. RESULTS: The position of the fetal head was determined by ultrasound examination in all 496 cases examined. Digital examination failed to define the fetal head position in 166 (33.5%) cases and, in 330 cases where the position was determined, the findings of the digital and sonographic examinations were in agreement in only 163 (49.4%) cases. The rate of correct identification of the fetal position by digital examination increased with cervical dilatation, from 20.5% at 3-4 cm to 44.2% at 8-10 cm, and was higher if the examination was carried out by an obstetrician than a midwife (50% versus 30%) and if there was absence rather than presence of caput (33% versus 25%). CONCLUSIONS: Routine digital examination during labor fails to identify the correct fetal position in the majority of cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new method to assess fetal head descent in labor with transperineal ultrasound
Barbera, A. F., Pombar, X., Perugino, G., Lezotte, D. C., & Hobbins, J. C. (2009) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.6329 · Cited by 349
Kalache, K. D., Dückelmann, A. M., Michaelis, S. A. M., Lange, J., Cichon, G., & Dudenhausen, J. W. (2009) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.6294 · Cited by 262
Ghi, T., Conversano, F., Ramirez Zegarra, R., Pisani, P., Dall'Asta, A., Lanzone, A., Lau, W., Vimercati, A., Iliescu, D. G., Mappa, I., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23739 · Cited by 32
Guittier, M.-J., & Othenin-Girard, V. (2012) · Gynécologie Obstétrique & Fertilité · doi:10.1016/j.gyobfe.2011.05.006 · Cited by 11
Metadata
- Authors
- Akmal, S., Tsoi, E., Kametas, N. A., Howard, R., & Nicolaides, K. H.
- Venue
- The Journal of Maternal-Fetal & Neonatal Medicine
- Publisher
- Informa
- Published
- 2002-01-01
- Volume
- 12
- Issue
- 3
- Pages
- 172-177
- ISSN
- 1476-4954 (ISSN-L)
- OpenAlex
- W2009456537
- Cited by
- 212
- References
- 0
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intrapartum sonography to determine fetal head position. https://app.cochat.ai/papers/10.1080/713605646
- The paper
- Akmal, S., Tsoi, E., Kametas, N. A., Howard, R., & Nicolaides, K. H. (2002). Intrapartum sonography to determine fetal head position. The Journal of Maternal-Fetal & Neonatal Medicine. https://doi.org/10.1080/713605646
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.