The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Stimulus-Responsive “Smart” Hydrogels as Novel Drug Delivery Systems
Abstract
Recently, there has been a great deal of research activity in the development of stimulus-responsive polymeric hydrogels. These hydrogels are responsive to external or internal stimuli and the response can be observed through abrupt changes in the physical nature of the network. This property can be favorable in many drug delivery applications. The external stimuli can be temperature, pH, ionic strength, ultrasonic sound, electric current, etc. A majority of the literature related to the development of stimulus-responsive drug delivery systems deals with temperature-sensitive poly(N-isopropyl acrylamide) (pNIPAAm) and its various derivatives. However, acrylic-based pH-sensitive systems with weakly acidic/basic functional groups have also been widely studied. Quite recently, glucose-sensitive hydrogels that are responsive to glucose concentration have been developed to monitor the release of insulin. The present article provides a brief introduction and recent developments in the area of stimulus-responsive hydrogels, particularly those that respond to temperature and pH, and their applications in drug delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kohori, F., Sakai, K., Aoyagi, T., Yokoyama, M., Sakurai, Y., & Okano, T. (1998) · Journal of Controlled Release · doi:10.1016/s0168-3659(98)00023-6 · Cited by 273
Cited by
Hydrogels in controlled release formulations: Network design and mathematical modeling
Lin, C.-C., & Metters, A. T. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.004 · Cited by 1,768
Responsive polymers in controlled drug delivery
Bajpai, A. K., Shukla, S. K., Bhanu, S., & Kankane, S. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.005 · Cited by 1,391
Thermo-responsive polymers and their application as smart biomaterials
Kim, Y.-J., & Matsunaga, Y. T. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb00157f · Cited by 568
El-Husseiny, H. M., Mady, E. A., Hamabe, L., Abugomaa, A., Shimada, K., Yoshida, T., Tanaka, T., Yokoi, A., Elbadawy, M., & Tanaka, R. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100186 · Cited by 533
Release mechanisms for polyelectrolyte capsules
De Geest, B. G., Sanders, N. N., Sukhorukov, G. B., Demeester, J., & De Smedt, S. C. (2007) · Chem. Soc. Rev. · doi:10.1039/b600460c · Cited by 462
Metadata
- Authors
- Soppimath, K. S., Aminabhavi, T. M., Dave, A. M., Kumbar, S. G., & Rudzinski, W. E.
- Venue
- Drug Development and Industrial Pharmacy
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 28
- Issue
- 8
- Pages
- 957-974
- ISSN
- 0363-9045 (ISSN-L)
- 1520-5762
- OpenAlex
- W2043860148
- Cited by
- 389
- References
- 1
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stimulus-Responsive “Smart” Hydrogels as Novel Drug Delivery Systems. https://app.cochat.ai/papers/10.1081/ddc-120006428
- The paper
- Soppimath, K. S., Aminabhavi, T. M., Dave, A. M., Kumbar, S. G., & Rudzinski, W. E. (2002). Stimulus-Responsive “Smart” Hydrogels as Novel Drug Delivery Systems. Drug Development and Industrial Pharmacy. https://doi.org/10.1081/ddc-120006428
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.