The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Plasma Treatment of Polymers
Abstract
Plasma treatment of polymers encompasses a variety of plasma technologies and polymeric materials for a wide range of applications and dates back to at least the 1960s. In this article we provide a brief review of the United States patent literature on plasma surface modification technologies and a brief review of the scientific literature on investigations of the effects of plasma treatment, the nature of the plasma environment, and the mechanisms that drive the plasma–surface interaction. We then discuss low‐radio‐frequency capacitively coupled nitrogen plasmas and their characteristics, suggesting that they provide significant plasma densities and populations of reactive species for effective plasma treatments on a variety of materials, particularly when placing the sample surface in the cathode sheath region. We further discuss surface chemical characterization of treated polymers, including some results on polyesters treated in capacitively coupled nitrogen plasmas driven at 40 kHz. Finally, we connect plasma characterization with surface chemical analysis by applying a surface sites model to nitrogen uptake of poly(ethylene terephthalate) (PET) and poly(ethylene naphthalate) (PEN) treated in a 40 kHz nitrogen plasma. This example serves to suggest an interesting practical approach to comparisons of plasma treatments. In addition, it suggests an approach to defining the investigations required to conclusively identify the underlying treatment mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Principles of Plasma Discharges and Materials Processing
Lieberman, M. A., & Lichtenberg, A. J. (2005) · doi:10.1002/0471724254 · Cited by 4,748
Practical surface analysis: By auger and x-ray photoelectron spectroscopy
Briggs, D., & Seah, M. P. (1983) · Medical Entomology and Zoology · Cited by 4,292
Practical surface analysis by auger and X-ray photoelectron spectroscopy
Oelhafen, P. (1984) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/0368-2048(84)80044-4 · Cited by 2,498
Silicon Processing for the VLSI Era
Wolf, S. M., & Tauber, R. N. (1986) · Medical Entomology and Zoology · Cited by 1,541
(1985) · Elsevier eBooks · doi:10.1016/c2012-0-01688-2 · Cited by 1,134
Plasma surface modification of polymers for improved adhesion: a critical review
Liston, E. M., Martinu, L., & Wertheimer, M. R. (1993) · Journal of Adhesion Science and Technology · doi:10.1163/156856193x00600 · Cited by 1,091
Massines, F., Rabehi, A., Decomps, P., Gadri, R. B., Ségur, P., & Mayoux, C. (1998) · Journal of Applied Physics · doi:10.1063/1.367051 · Cited by 955
Benninghoven, A. (1994) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199410231 · Cited by 535
Photochemistry of man-made polymers
McKellar, J. F., & Allen, N. S. (1979) · Applied Science Publishers eBooks · Cited by 297
Self-consistent model of a direct-current glow discharge: Treatment of fast electrons
Surendra, M., Graves, D. B., & Jellum, G. M. (1990) · Physical Review A · doi:10.1103/physreva.41.1112 · Cited by 281
Boenig, H. (1982) · Cornell University Press eBooks · doi:10.7591/9781501741388 · Cited by 278
Mechanisms controlling the transition from glow silent discharge to streamer discharge in nitrogen
Ghérardi, N., & Massines, F. (2001) · IEEE Transactions on Plasma Science · doi:10.1109/27.928953 · Cited by 237
Industrial processing of polymers by low-pressure plasmas: the role of VUV radiation
Wertheimer, M. R., Fozza, A. C., & Holländer, A. (1999) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(99)00073-7 · Cited by 230
Chilkoti, A., Ratner, B. D., & Briggs, D. (1991) · Chemistry of Materials · doi:10.1021/cm00013a016 · Cited by 210
Metal-polymer interfaces: Adhesion and x-ray photoemission studies
Burkstrand, J. M. (1981) · Journal of Applied Physics · doi:10.1063/1.329320 · Cited by 209
Occhiello, E., Morra, M., Morini, G., Garbassi, F., & Humphrey, P. (1991) · Journal of Applied Polymer Science · doi:10.1002/app.1991.070420228 · Cited by 164
A comparison of gas-phase methods of modifying polymer surfaces
Strobel, M., Walzak, M. J., Hill, J. M., Lin, A. W., Karbashewski, E., & Lyons, C. S. (1995) · Journal of Adhesion Science and Technology · doi:10.1163/156856195x00554 · Cited by 140
Gerenser, L. J. (1988) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.575448 · Cited by 123
Self-citationFally, F., Doneux, C., Riga, J., & Verbist, J. J. (1995) · Journal of Applied Polymer Science · doi:10.1002/app.1995.070560509 · Cited by 95
Strobel, M., Lyons, C. S., Strobel, J. M., & Kapaun, R. S. (1992) · Journal of Adhesion Science and Technology · doi:10.1163/156856192x00764 · Cited by 85
McCurdy, P. R., Bogart, K. H. A., Dalleska, N. F., & Fisher, E. R. (1997) · Review of Scientific Instruments · doi:10.1063/1.1147976 · Cited by 72
Creating Smart Polymer Surfaces with Selective Adhesion Properties
Koberstein, J. T., Duch, D. E. D., Hu, W., et al. (1998) · The Journal of Adhesion · doi:10.1080/00218469808009967 · Cited by 71
Oxygen plasma modification of polyimide webs: effect of ion bombardment on metal adhesion
Egitto, F. D., Matienzo, L. J., Blackwell, K., & Knoll, A. (1994) · Journal of Adhesion Science and Technology · doi:10.1163/156856194x00311 · Cited by 38
ESCA Analysis of Photodegraded Poly(ethylene terephthalate) Film Utilizing Gas Chemical Modification
NAKAYAMA, Y., TAKAHASHI, K., & Sasamoto, T. (1996) · Surface and Interface Analysis · doi:10.1002/(sici)1096-9918(19960930)24:10<711::aid-sia184>3.0.co;2-a · Cited by 25
Cited by
Surface-functionalized electrospun nanofibers for tissue engineering and drug delivery
Yoo, H. S., Kim, T. G., & Park, T. G. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.07.007 · Cited by 1,095
Siow, K. S., Britcher, L., Kumar, S., & Griesser, H. J. (2006) · Plasma Processes and Polymers · doi:10.1002/ppap.200600021 · Cited by 972
Electrospinning for tissue engineering applications
Rahmati, M., Mills, D. K., Urbanska, A. M., Saeb, M. R., Venugopal, J. R., Ramakrishna, S., & Mozafari, M. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100721 · Cited by 816
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Desmet, T., Morent, R., De Geyter, N., Leys, C., Schacht, E., & Dubruel, P. (2009) · Biomacromolecules · doi:10.1021/bm900186s · Cited by 689
Metadata
- Authors
- Grace, J. M., & Gerenser, L. J.
- Venue
- Journal of Dispersion Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2003-01-07
- Volume
- 24
- Issue
- 3-4
- Pages
- 305-341
- ISSN
- 0193-2691 (ISSN-L)
- 1532-2351
- OpenAlex
- W2040018167
- Cited by
- 353
- References
- 25
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.