Cited by 14Cardiac Imaging and DiagnosticsAdvanced MRI Techniques and ApplicationsCoronary Artery Anomalies

Three-Dimensional Magnetic Resonance Coronary Angiography Using a New Blood Pool Contrast Agent: Initial Experience

Bedaux, Willemijn L. F., Hofman, Mark B. M., Wielopolski, Piotr A., de Cock, Carel C., Hoffmann, Volker, Oudkerk, Matthijs, de Feyter, Pim J., van Rossum, Albert C.·2002·Journal of Cardiovascular Magnetic Resonance

Abstract

Objective The aim of this feasibility study was to assess the effect of a new blood pool contrast agent on magnetic resonance coronary angiography (MRCA) in patients suspected of having coronary artery disease. Methods Nine patients referred for diagnostic x-ray coronary angiography in the evaluation of chest pain underwent MRCA using a thin-slab three-dimensional (3D) breath-hold segmented gradient echo technique at 1.5 T before and after intravenous administration of feruglose, a new blood pool contrast agent. Results A total of 36 coronary arteries, including 15 stenoses were evaluated. Overall agreement of visually assessed stenoses > 50% was 86%. The mean signal-to-noise ratio in the left anterior descending artery (LAD) did not change significantly after contrast administration, a relative improvement of 1.2 +/- 0.4 (p = 0.1), whereas the mean contrast-to-noise ratio of blood to myocardium improved by 3 +/- 2 (p = 0.01). Conclusion A thin-slab 3D breath-hold scan combined with feruglose allows rapid localization and coverage of the proximal coronary arteries.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1081/jcmr-120003953

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Feruglose has been proven suitable for visualization of proximal coronary arteries with thin slab 3D breath hold scans.

    “Together with thin slab 3D breath hold scans, feruglose has been proven to be suitable for the visualization of proximal coronary arteries [185].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cited by

Sorted by citations

Authors
Bedaux, W. L. F., Hofman, M. B. M., Wielopolski, P. A., de Cock, C. C., Hoffmann, V., Oudkerk, M., de Feyter, P. J., & van Rossum, A. C.
Affiliations
  • Vrije Universiteit Amsterdam (NL)
  • Erasmus University Rotterdam (NL)
Venue
Journal of Cardiovascular Magnetic Resonance
Publisher
Elsevier BV
Published
2002
Volume
4
Issue
2
Pages
273-282
ISSN
  • 1097-6647 (ISSN-L)
  • 1532-429X
OpenAlex
W2143612860
Cited by
14
References
0
Citations by year
2023: 1 · 2019: 1
FWCI
2.26
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Cardiovascular Magnetic Resonance (publishedVersion)
  • PubMed (publishedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (publishedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
  • Pure Amsterdam UMC (submittedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Coronary Artery Anomalies
Keywords
coronary magnetic resonance angiography, blood pool contrast agent, coronary artery disease, coronary artery stenosis, signal-to-noise ratio, contrast-to-noise ratio, left anterior descending artery, diagnostic accuracy
MeSH terms
Aged, Contrast Media, Coronary Artery Disease, Coronary Vessels, Feasibility Studies, Female, Humans, Image Enhancement, Iron, Male, Middle Aged, Oxides, Magnetic Resonance Angiography, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review