The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
UPLC™: An Introduction and Review
Abstract
Ultra performance liquid chromatography™ (UPLC) takes advantage of technological strides made in particle chemistry performance, system optimization, detector design, and data processing and control. Using sub‐2 µm particles and mobile phases at high linear velocities, and instrumentation that operates at higher pressures than those used in HPLC, dramatic increases in resolution, sensitivity, and speed of analysis can be obtained. This new category of analytical separation science retains the practicality and principles of HPLC while creating a step‐function improvement in chromatographic performance. This review introduces the theory of UPLC, and summarizes some of the most recent work in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromatography
van Deemter, J. J., Zuiderweg, F. J., & Klinkenberg, A. (1956) · Chemical Engineering Science · doi:10.1016/0009-2509(56)80003-1 · Cited by 1,698
Ultrahigh-Pressure Reversed-Phase Liquid Chromatography in Packed Capillary Columns
MacNair, J. E., Lewis, K. C., & Jorgenson, J. W. (1997) · Analytical Chemistry · doi:10.1021/ac961094r · Cited by 584
Plumb, R., Castro‐Perez, J., Granger, J., Beattie, I., Joncour, K., & Wright, A. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1627 · Cited by 342
Very High Pressure Gradient LC/MS/MS
Tolley, L. T., Jorgenson, J. W., & Moseley, M. A. (2001) · Analytical Chemistry · doi:10.1021/ac0010835 · Cited by 106
Fast LC/MS in the analysis of small molecules
Tiller, P. R., Romanyshyn, L. A., & Neue, U. D. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2146-0 · Cited by 69
Very high pressure HPLC with 1 mm id columns
Colón, L. A., Cintrón, J. M., Anspach, J. A., Fermier, A. M., & Swinney, K. A. (2004) · The Analyst · doi:10.1039/b405242k · Cited by 61
Cited by
Yoshimatsu, K., Reimhult, K., Krozer, A., Mosbach, K., Sode, K., & Ye, L. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.11.004 · Cited by 427
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Flavor of tea ( Camellia sinensis ): A review on odorants and analytical techniques
Zhai, X., Zhang, L., Granvogl, M., Ho, C., & Wan, X. (2022) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12999 · Cited by 366
Dunn, W. B. (2008) · Physical Biology · doi:10.1088/1478-3975/5/1/011001 · Cited by 278
Proteins in Art, Archaeology, and Paleontology: From Detection to Identification
Dallongeville, S., Garnier, N., Rolando, C., & Tokarski, C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00037 · Cited by 172
Metadata
- Authors
- Swartz, M. E.
- Venue
- Journal of Liquid Chromatography & Related Technologies
- Publisher
- Informa UK Limited
- Published
- 2005-04
- Volume
- 28
- Issue
- 7-8
- Pages
- 1253-1263
- ISSN
- 1082-6076 (ISSN-L)
- 1520-572X
- OpenAlex
- W2023807377
- Cited by
- 571
- References
- 6
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: UPLC™: An Introduction and Review. https://app.cochat.ai/papers/10.1081/jlc-200053046
- The paper
- Swartz, M. E. (2005). UPLC™: An Introduction and Review. Journal of Liquid Chromatography & Related Technologies. https://doi.org/10.1081/jlc-200053046
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.