The DOI matches its Crossref record.
Ultrahigh-Pressure Reversed-Phase Liquid Chromatography in Packed Capillary Columns
Abstract
The use of extremely high pressures in liquid chromatography can improve the efficiency and reduce analysis time for columns packed with small particles. In this work, fused-silica capillaries with inner diameters of 30 microns are slurry packed with 1.5 microns nonporous octadecylsilane-modified silica particles. These columns are prepared in lengths up to 66 cm with packing pressures as high as 4100 bar (60,000 psi). Near the optimum flow rate, columns generate as many as 300,000 theoretical plates for lightly retained compounds (k' < 0.5) and over 200,000 plates for more retained compounds (k' approximately 2). These translate to plate heights (Hmin) as low as 2.1 microns. The pressures required to run at optimum flow rates are on the order of 1400 bar (20,000 psi). Analysis times at these pressures are on the order of 30 min (k' approximately 2) and can be reduced to less than 10 min at higher than optimum flow rates. Capacity factors are observed to increase linearly with applied pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Fast analysis in liquid chromatography using small particle size and high pressure
Nguyen, D. T. ‐., Guillarme, D., Rudaz, S., & Veuthey, J. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600189 · Cited by 337
Analytical and statistical approaches to metabolomics research
Issaq, H. J., Van, Q. N., Waybright, T. J., Muschik, G. M., & Veenstra, T. D. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900152 · Cited by 227
Rapid and Deep Human Proteome Analysis by Single-dimension Shotgun Proteomics
Pirmoradian, M., Budamgunta, H., Chingin, K., Zhang, B., Astorga-Wells, J., & Zubarev, R. A. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o113.028787 · Cited by 144
The Revolution and Evolution of Shotgun Proteomics for Large-Scale Proteome Analysis
Yates, J. R. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3094313 · Cited by 131
Metadata
- Authors
- MacNair, J. E., Lewis, K. C., & Jorgenson, J. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-03-01
- Volume
- 69
- Issue
- 6
- Pages
- 983-989
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2013029357
- Cited by
- 584
- References
- 0
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahigh-Pressure Reversed-Phase Liquid Chromatography in Packed Capillary Columns. https://app.cochat.ai/papers/10.1021/ac961094r
- The paper
- MacNair, J. E., Lewis, K. C., & Jorgenson, J. W. (1997). Ultrahigh-Pressure Reversed-Phase Liquid Chromatography in Packed Capillary Columns. Analytical Chemistry. https://doi.org/10.1021/ac961094r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.