THE CROSSFLOW INJECTION TECHNIQUE: AN IMPROVEMENT OF THE ETHANOL INJECTION METHOD
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel scalable liposome preparation technique for pharmaceutical application is presented. Previous experiments have shown that the concept of continuous crossflow injection is a promising approach. For the characterization of the process, we focus on the influencing parameters like the lipid concentration, the injection hole diameter, the injection pressure, the buffer flow rate, and system performance. These experiments demonstrate that the injection hole diameter and the system performance do not influence the vesicle forming process and that a minimum of buffer flow rate is required to affect batch homogeneity. In contrast, strongly influencing parameters are lipid concentration in combination with increasing injection pressures. After exceeding the upper pressure limit of the linear range, where injection velocities remain constant, the vesicle batches are narrowly distributed, also when injecting higher lipid concentrations. Reproducibility and scalability data show similar results with respect to vesicle size and size distribution and demonstrate the stability and robustness of the novel continuous liposome preparation technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion of univalent ions across the lamellae of swollen phospholipids
Bangham, A. D., Standish, M. M., & Watkins, J. C. (1965) · Journal of Molecular Biology · doi:10.1016/s0022-2836(65)80093-6 · Cited by 4,664
Cited by
New developments in liposomal drug delivery
Pattni, B. S., Chupin, V. V., & Torchilin, V. P. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00046 · Cited by 1,600
Liu, P., Chen, G., & Zhang, J. (2022) · Molecules · doi:10.3390/molecules27041372 · Cited by 1,334
“, Shirasu Porous Glass membrane [84] or hollow fiber configuration [85]) and crossflow injection [86,87] device to improve the micromixing of the organic phase into the aqueous phase.”
BackgroundLiposomes: Technologies and Analytical Applications
Jesorka, A., & Orwar, O. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112747 · Cited by 569
Liposome Technology for Industrial Purposes
Wagner, A., & Vorauer-Uhl, K. (2011) · Journal of Drug Delivery · doi:10.1155/2011/591325 · Cited by 435
Self-citationMicrofluidic Mixing and the Formation of Nanoscale Lipid Vesicles
Jahn, A., Stavis, S. M., Hong, J. S., Vreeland, W. N., DeVoe, D. L., & Gaitan, M. (2010) · ACS Nano · doi:10.1021/nn901676x · Cited by 432
Metadata
- Authors
- Wagner, A., Vorauer-Uhl, K., Kreismayr, G., & Katinger, H.
- Venue
- Journal of Liposome Research
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 12
- Issue
- 3
- Pages
- 259-270
- ISSN
- 0898-2104 (ISSN-L)
- 1532-2394
- OpenAlex
- W2137913086
- Cited by
- 122
- References
- 1
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.