Kinetic separation of methane/carbon dioxide by molecular sieve carbons
The DOI matches its Crossref record.
Abstract
The bulk separation of CH4/CO2 mixture by pressure swing adsorption (PSA) on two different types of carbon molecular sieves (CMS) is analyzed. The two CMS are Bergbau–Forschung (BF) CMS and Takeda 3A CMS. Two different PSA cycles are considered, differing by whether a feed step is used. For a 50/50 feed mixture, it is shown that the separation is feasible with both sorbents to produce a methane product at over 90% purity and at reasonably high product recoveries and sorbent productivities. It is shown in this work that temperature is an important factor to consider for kinetics-based separations, and that a higher temperature is favorable for CH4/CO2 separation on molecular sieve where diffusion is slow. At 25°C, BF CMS yields better separation because the diffusion of both CO2 and CH4 are slow in the Takeda 3A CMS. Increasing the temperature decreases the equilibrium adsorption amounts, but increases the diffusivities. The separation results with Takeda 3A are substantially improved when the temperature is increased to 70°C, and the separation is better than that of BF CMS at 25°C. Therefore, the rate of diffusion (rather than equilibrium) is the dominating factor in kinetics-based separations. The effects of the sorbent working capacity (defined as the difference in the amounts adsorbed of the fast diffusing component between the ends of the adsorption step and the desorption step) on the separation are illustrated. For the kinetics-based separation, a high-pressure feed step is desirable while a low-pressure purge step is not desirable. The reasons are seen clearly from the bed profiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adsorbent Materials for Carbon Dioxide Capture from Large Anthropogenic Point Sources
Choi, S., Drese, J. H., & Jones, C. W. (2009) · ChemSusChem · doi:10.1002/cssc.200900036 · Cited by 2,596
Natural gas origin, composition, and processing: A review
Faramawy, S., Zaki, T., & Sakr, A. A.-E. (2016) · Journal of Natural Gas Science and Engineering · doi:10.1016/j.jngse.2016.06.030 · Cited by 788
Natural gas treating by selective adsorption: Material science and chemical engineering interplay
Tagliabue, M., Farrusseng, D., Valencia, S., Aguado, S., Ravon, U., Rizzo, C., Corma, A., & Mirodatos, C. (2009) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.09.010 · Cited by 471
Saha, D., Grappe, H. A., Chakraborty, A., & Orkoulas, G. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00745 · Cited by 316
Separation of CH4/CO2/N2 mixtures by layered pressure swing adsorption for upgrade of natural gas
Cavenati, S., Grande, C. A., & Rodrigues, A. E. (2006) · Chemical Engineering Science · doi:10.1016/j.ces.2006.01.023 · Cited by 302
Metadata
- Authors
- Jayaraman, A., Chiao, A. S., Padin, J., Yang, R. T., & Munson, C. L.
- Venue
- Separation Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2002-07-24
- Volume
- 37
- Issue
- 11
- Pages
- 2505-2528
- ISSN
- 0149-6395 (ISSN-L)
- 1520-5754
- OpenAlex
- W2053898436
- Cited by
- 57
- References
- 0
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinetic separation of methane/carbon dioxide by molecular sieve carbons. https://app.cochat.ai/papers/10.1081/ss-120004450
- The paper
- Jayaraman, A., Chiao, A. S., Padin, J., Yang, R. T., & Munson, C. L. (2002). Kinetic separation of methane/carbon dioxide by molecular sieve carbons. Separation Science and Technology. https://doi.org/10.1081/ss-120004450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.