The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Examination of the Potential of Ionic Liquids for Gas Separations
Abstract
:Ionic liquids have received increasing interest in recent years for “green” synthesis and separations because they have essentially no vapor pressure. We have begun an investigation of the potential of ionic liquids for gas separations, including the removal of carbon dioxide from stack gas generated in coal-fired power plants. In this paper, we report results from measurements of the permeance of nitrogen and carbon dioxide in supported ionic liquid membranes. Preliminary results for a porous alumina membrane saturated with l-butyl-3-methyl imidazolium bis[trinuoromethylsulfonyl] amide yielded a CO2 : N2 selectivity of 127. Using previously reported measurements of CO2 solubility in ionic liquids (1) and the measured membrane transport characteristics, a preliminary economic analysis of a separation process based on supported ionic liquid membranes has been performed. A comparison of cost estimates for this membrane-based separation to cost estimates reported for carbon dioxide removal using a conventional amine scrubbing operation shows that, with continued technology development, an ionic liquid membrane process may potentially be economically competitive with amine scrubbing. A preliminary cost estimate for an ionic liquid scrubber indicates that an ionic liquid absorption process shows less favorable economics than a supported ionic liquid membrane or an amine scrubber. However, results indicate that a more comprehensive technical and economic assessment is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrophobic, Highly Conductive Ambient-Temperature Molten Salts
Bonhôte, P., Dias, A.-P., Papageorgiou, N., Kalyanasundaram, K., & Grätzel, M. (1996) · Inorganic Chemistry · doi:10.1021/ic951325x · Cited by 4,358
Influence of chloride, water, and organic solvents on the physical properties of ionic liquids
Seddon, K. R., Stark, A., & Torres, M.-J. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072122275 · Cited by 2,293
CO2 Capture by a Task-Specific Ionic Liquid
Bates, E. D., Mayton, R. D., Ntai, I., & Davis, J. H. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017593d · Cited by 2,270
A short history of ionic liquids—from molten salts to neoteric solvents
Wilkes, J. S. (2002) · Green Chemistry · doi:10.1039/b110838g · Cited by 1,684
Ionic liquids: Innovative fluids for chemical processing
Brennecke, J. F., & Maginn, E. J. (2001) · AIChE Journal · doi:10.1002/aic.690471102 · Cited by 1,432
Anthony, J. L., Maginn, E. J., & Brennecke, J. F. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp020631a · Cited by 974
The Performance and Stability of Ambient Temperature Molten Salts for Solar Cell Applications
Papageorgiou, N., Athanassov, Y., Armand, M., Bonho⁁te, P., Pettersson, H., Azam, A., & Grätzel, M. (1996) · Journal of The Electrochemical Society · doi:10.1149/1.1837171 · Cited by 739
Solvent extraction of strontium nitrate by a crown ether using room-temperature ionic liquids †
Dai, S., Ju, Y. H., & Barnes, C. E. (1999) · Journal of the Chemical Society, Dalton Transactions · doi:10.1039/a809672d · Cited by 705
Self-citationJastorff, B., Störmann, R., Ranke, J., Mölter, K., Stock, F., Oberheitmann, B., Hoffmann, W., Hoffmann, J., Nüchter, M., Ondruschka, B., et al. (2003) · Green Chemistry · doi:10.1039/b211971d · Cited by 363
Room temperature ionic liquids as replacements for conventional solvents – A review
Marsh, K. N., Deev, A., Wu, A. C.-T., Tran, E., & Klamt, A. (2002) · Korean Journal of Chemical Engineering · doi:10.1007/bf02697140 · Cited by 361
Baltus, R. E., Culbertson, B. H., Dai, S., Luo, H., & DePaoli, D. W. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp036051a · Cited by 333
Self-citationNew fluorous ionic liquids function as surfactants in conventional room-temperature ionic liquids
Merrigan, T. L., Bates, E. D., Dorman, S. C., & Davis Jr., J. H. (2000) · Chemical Communications · doi:10.1039/b005418f · Cited by 301
Branco, L. C., Crespo, J. G., & Afonso, C. A. M. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020802)41:15<2771::aid-anie2771>3.0.co;2-u · Cited by 234
From curiosities to commodities: ionic liquids begin the transition
Davis, Jr., & Fox, P. A. (2003) · Chemical Communications · doi:10.1039/b212788a · Cited by 226
Liang, C., Yuan, C.-Y., Warmack, R. J. B., Barnes, C. E., & Dai, S. (2002) · Analytical Chemistry · doi:10.1021/ac011007h · Cited by 143
Self-citationElectrochemical Separation and Concentration of <1% Carbon Dioxide from Nitrogen
Scovazzo, P., Poshusta, J., DuBois, D. L., Koval, C. A., & Noble, R. D. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1566962 · Cited by 122
Supported Ionic Liquid Membranes and Facilitated Ionic Liquid Membranes
Scovazzo, P., Visser, A. E., Davis, J. H., et al. (2002) · ACS symposium series · doi:10.1021/bk-2002-0818.ch006 · Cited by 90
CO2 Separation and Fuel Desulfurization Involving Room-Temperature Ionic Liquids
Culbertson, B. H. (2003) · Cited by 2
Self-citation
Cited by
State-of-the-Art of CO2Capture with Ionic Liquids
Ramdin, M., de Loos, T. W., & Vlugt, T. J. H. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie3003705 · Cited by 1,073
Han, X., & Armstrong, D. W. (2007) · Accounts of Chemical Research · doi:10.1021/ar700044y · Cited by 1,024
Density and viscosity of several pure and water-saturated ionic liquids
Jacquemin, J., Husson, P., Padua, A. A. H., & Majer, V. (2006) · Green Chem. · doi:10.1039/b513231b · Cited by 847
Improving Carbon Dioxide Solubility in Ionic Liquids
Muldoon, M. J., Aki, S. N. V. K., Anderson, J. L., Dixon, J. K., & Brennecke, J. F. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp071897q · Cited by 800
Guide to CO2 Separations in Imidazolium-Based Room-Temperature Ionic Liquids
Bara, J. E., Carlisle, T. K., Gabriel, C. J., Camper, D., Finotello, A., Gin, D. L., & Noble, R. D. (2009) · Industrial & Engineering Chemistry Research · doi:10.1021/ie8016237 · Cited by 714
Metadata
- Authors
- Baltus, R. E., Counce, R. M., Culbertson, B. H., Luo, H., DePaoli, D. W., Dai, S., & Duckworth, D. C.
- Venue
- Separation Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2005-02-01
- Volume
- 40
- Issue
- 1-3
- Pages
- 525-541
- ISSN
- 0149-6395 (ISSN-L)
- 1520-5754
- OpenAlex
- W1972002419
- Cited by
- 256
- References
- 18
- FWCI
- 26.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.