The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Microtubule depolymerization promotes particle and chromosome movement in vitro.
Open accessAbstract
We have developed a system for studying the motions of cellular objects attached to depolymerizing microtubules in vitro. Radial arrays of microtubules were grown from lysed and extracted Tetrahymena cells attached to a glass coverslip that formed the top of a light microscope perfusion chamber. A preparation of chromosomes, which also contained vesicles, was then perfused into the chamber and allowed to bind to the microtubule array. The concentration of tubulin was then reduced by perfusing buffer that lacked both tubulin and nucleotide triphosphates, and the resulting microtubule depolymerization was observed by light microscopy. A fraction of the bound objects detached in the flow and washed away, while others stabilized the microtubules to which they were bound. Some of the particles and chromosomes, however, moved in toward the Tetrahymena ghost as their associated microtubules shortened. The mean speeds for particles and chromosomes were 26 +/- 20 and 15 +/- 12 microns/min, respectively. These motions occurred when nucleotide triphosphate levels were very low, as a result of either dilution or by the action of apyrase. Furthermore, the motions were unaffected by 100 microM sodium orthovanadate, suggesting that these forces are not the result of ATP hydrolysis by a minus end-directed mechanoenzyme. We conclude that microtubule depolymerization provided the free energy for the motions observed. All the objects that we studied in detail moved against a stream of buffer flowing at approximately 100 microns/s, so that the force being developed was at least 10(-7) dynes. This force is large enough to contribute to some forms of motility in living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Walker, R. A., O'Brien, E. T., Pryer, N. K., Soboeiro, M. F., Voter, W. A., Erickson, H. P., & Salmon, E. D. (1988) · The Journal of Cell Biology · doi:10.1083/jcb.107.4.1437 · Cited by 980
Cited by
Dynamics and mechanics of the microtubule plus end
Howard, J., & Hyman, A. A. (2003) · Nature · doi:10.1038/nature01600 · Cited by 747
Microtubule attachment and spindle assembly checkpoint signalling at the kinetochore
Foley, E. A., & Kapoor, T. M. (2013) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3494 · Cited by 636
Measurement of the Force-Velocity Relation for Growing Microtubules
Dogterom, M., & Yurke, B. (1997) · Science · doi:10.1126/science.278.5339.856 · Cited by 579
Microtubule dynamics: an interplay of biochemistry and mechanics
Brouhard, G. J., & Rice, L. M. (2018) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-018-0009-y · Cited by 564
Microtubule dynamics and microtubule caps: a time-resolved cryo-electron microscopy study.
Mandelkow, E. M., Mandelkow, E., & Milligan, R. A. (1991) · The Journal of cell biology · doi:10.1083/jcb.114.5.977 · Cited by 552
Metadata
- Authors
- Coue, M., Lombillo, V. A., & McIntosh, J. R.
- Venue
- The Journal of cell biology
- Publisher
- Rockefeller University Press
- Published
- 1991-03-15
- Volume
- 112
- Issue
- 6
- Pages
- 1165-1175
- ISSN
- 0021-9525 (ISSN-L)
- 1540-8140
- OpenAlex
- W2114083778
- Cited by
- 215
- References
- 1
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microtubule depolymerization promotes particle and chromosome movement in vitro. https://app.cochat.ai/papers/10.1083/jcb.112.6.1165
- The paper
- Coue, M., Lombillo, V. A., & McIntosh, J. R. (1991). Microtubule depolymerization promotes particle and chromosome movement in vitro. The Journal of cell biology. https://doi.org/10.1083/jcb.112.6.1165
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.