The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Virtual nanoscopy: Generation of ultra-large high resolution electron microscopy maps
Open accessAbstract
A key obstacle in uncovering the orchestration between molecular and cellular events is the vastly different length scales on which they occur. We describe here a methodology for ultrastructurally mapping regions of cells and tissue as large as 1 mm2 at nanometer resolution. Our approach employs standard transmission electron microscopy, rapid automated data collection, and stitching to create large virtual slides. It greatly facilitates correlative light-electron microscopy studies to relate structure and function and provides a genuine representation of ultrastructural events. The method is scalable as illustrated by slides up to 281 gigapixels in size. Here, we applied virtual nanoscopy in a correlative light-electron microscopy study to address the role of the endothelial glycocalyx in protein leakage over the glomerular filtration barrier, in an immunogold labeling study of internalization of oncolytic reovirus in human dendritic cells, in a cryo-electron microscopy study of intact vitrified mouse embryonic cells, and in an ultrastructural mapping of a complete zebrafish embryo slice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell biology of the glomerular podocyte
Pavenstädt, H., Kriz, W., & Kretzler, M. (2003) · Physiological Reviews · doi:10.1152/physrev.00020.2002 · Cited by 1,499
Eskelinen, E.-L. (2008) · Autophagy · doi:10.4161/auto.5179 · Cited by 197
Cited by
SARS-CoV-2 productively infects human gut enterocytes
Lamers, M. M., Beumer, J., van der Vaart, J., Knoops, K., Puschhof, J., Breugem, T. I., Ravelli, R. B. G., Paul van Schayck, J., Mykytyn, A. Z., Duimel, H. Q., et al. (2020) · Science · doi:10.1126/science.abc1669 · Cited by 1,573
Self-citationLong‐term expanding human airway organoids for disease modeling
Sachs, N., Papaspyropoulos, A., Zomer‐van Ommen, D. D., Heo, I., Böttinger, L., Klay, D., Weeber, F., Huelsz‐Prince, G., Iakobachvili, N., Amatngalim, G. D., et al. (2019) · The EMBO Journal · doi:10.15252/embj.2018100300 · Cited by 1,082
Giacomelli, E., Meraviglia, V., Campostrini, G., Cochrane, A., Cao, X., van Helden, R. W. J., Krotenberg Garcia, A., Mircea, M., Kostidis, S., Davis, R. P., et al. (2020) · Cell Stem Cell · doi:10.1016/j.stem.2020.05.004 · Cited by 622
Self-citationCorrelated light and electron microscopy: ultrastructure lights up!
de Boer, P., Hoogenboom, J. P., & Giepmans, B. N. G. (2015) · Nature Methods · doi:10.1038/nmeth.3400 · Cited by 526
Snijder, E. J., Limpens, R. W. A. L., de Wilde, A. H., de Jong, A. W. M., Zevenhoven-Dobbe, J. C., Maier, H. J., Faas, F. F. G. A., Koster, A. J., & Bárcena, M. (2020) · PLOS Biology · doi:10.1371/journal.pbio.3000715 · Cited by 477
Self-citation
Metadata
- Authors
- Faas, F. G. A., Avramut, M. C., M. van den Berg, B., Mommaas, A. M., Koster, A. J., & Ravelli, R. B. G.
- Venue
- Journal of Cell Biology
- Publisher
- Rockefeller University Press
- Published
- 2012-08-06
- Volume
- 198
- Issue
- 3
- Pages
- 457-469
- ISSN
- 0021-9525 (ISSN-L)
- 1540-8140
- OpenAlex
- W2096256459
- Cited by
- 169
- References
- 2
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Virtual nanoscopy: Generation of ultra-large high resolution electron microscopy maps. https://app.cochat.ai/papers/10.1083/jcb.201201140
- The paper
- Faas, F. G. A., Avramut, M. C., M. van den Berg, B., Mommaas, A. M., Koster, A. J., & Ravelli, R. B. G. (2012). Virtual nanoscopy: Generation of ultra-large high resolution electron microscopy maps. Journal of Cell Biology. https://doi.org/10.1083/jcb.201201140
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.