Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record.

C1q deviation test for the detection of immune complexes, aggregates of IgG, and bacterial products in human serum.

Open access
Sobel, A T, Bokisch, V A, Müller-Eberhard, H J·1975·The Journal of experimental medicine

Abstract

This report describes a new, rapid, sensitive, and quantitative method for the detection of immune complexes, endotoxins, and other complement activating materials in patients sera utilizing the ability of these substances to react with isolated C1q. The procedure is based on the inhibition of radiolabeled C1q binding to sensitized sheep erythrocytes by C1q-reactive substances in pathological sera. The C1q deviation test may be performed on 50 mu1 of serum, using 1 mug of radiolabeled C1q per sample. The procedure may be completed in 1.5-2 h, it is capable of detecting 5 mug of aggregated human IgG per ml of serum, and its coefficient of variation is 4.2%. Application of the test to the study of 193 sera from 43 patients with Dengue hemorrhagic fever showed a positive correlation between degree of C1q deviation and severity of disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1084/jem.142.1.139

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Sobel, A. T., Bokisch, V. A., & Müller-Eberhard, H. J.
Venue
The Journal of experimental medicine
Published
1975-07-01
Volume
142
Issue
1
Pages
139-150
ISSN
  • 0022-1007 (ISSN-L)
  • 1540-9538
OpenAlex
W2125360684
Cited by
225
References
0
FWCI
10.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: C1q deviation test for the detection of immune complexes, aggregates of IgG, and bacterial products in human serum. https://app.cochat.ai/papers/10.1084/jem.142.1.139
The paper
Sobel, A. T., Bokisch, V. A., & Müller-Eberhard, H. J. (1975). C1q deviation test for the detection of immune complexes, aggregates of IgG, and bacterial products in human serum. The Journal of experimental medicine. https://doi.org/10.1084/jem.142.1.139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.