The DOI matches its Crossref record.
Ion Conduction through C-Type Inactivated Shaker Channels
Open accessAbstract
C-type inactivation of Shaker potassium channels involves entry into a state (or states) in which the inactivated channels appear nonconducting in physiological solutions. However, when Shaker channels, from which fast N-type inactivation has been removed by NH2-terminal deletions, are expressed in Xenopus oocytes and evaluated in inside-out patches, complete removal of K+ ions from the internal solution exposes conduction of Na+ and Li+ in C-type inactivated conformational states. The present paper uses this observation to investigate the properties of ion conduction through C-type inactivated channel states, and demonstrates that both activation and deactivation can occur in C-type states, although with slower than normal kinetics. Channels in the C-type states appear “inactivated” (i.e., nonconducting) in physiological solutions due to the summation of two separate effects: first, internal K+ ions prevent Na+ ions from permeating through the channel; second, C-type inactivation greatly reduces the permeability of K+ relative to the permeability of Na+, thus altering the ion selectivity of the channel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kellenberger, S., & Schild, L. (2002) · Physiological Reviews · doi:10.1152/physrev.00007.2002 · Cited by 1,026
hERG K+Channels: Structure, Function, and Clinical Significance
Vandenberg, J. I., Perry, M. D., Perrin, M. J., Mann, S. A., Ke, Y., & Hill, A. P. (2012) · Physiological Reviews · doi:10.1152/physrev.00036.2011 · Cited by 696
The moving parts of voltage-gated ion channels
YELLEN, G. (1998) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583598003448 · Cited by 478
Structural mechanism of C-type inactivation in K+ channels
Cuello, L. G., Jogini, V., Cortes, D. M., & Perozo, E. (2010) · Nature · doi:10.1038/nature09153 · Cited by 477
Neuronal P2X transmitter-gated cation channels change their ion selectivity in seconds
Khakh, B. S., Bao, X. R., Labarca, C., & Lester, H. A. (1999) · Nature Neuroscience · doi:10.1038/7233 · Cited by 365
Metadata
- Authors
- Starkus, J. G., Kuschel, L., Rayner, M. D., & Heinemann, S. H.
- Venue
- The Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 1997-11-01
- Volume
- 110
- Issue
- 5
- Pages
- 539-550
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2040083201
- Cited by
- 188
- References
- 0
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ion Conduction through C-Type Inactivated Shaker Channels. https://app.cochat.ai/papers/10.1085/jgp.110.5.539
- The paper
- Starkus, J. G., Kuschel, L., Rayner, M. D., & Heinemann, S. H. (1997). Ion Conduction through C-Type Inactivated Shaker Channels. The Journal of General Physiology. https://doi.org/10.1085/jgp.110.5.539
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.