Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 478

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The moving parts of voltage-gated ion channels

YELLEN, GARY·1998·Quarterly Reviews of Biophysics

Abstract

Ion channels, like many other proteins, have moving parts that perform useful functions. The channel proteins contain an aqueous, ion-selective pore that crosses the plasma membrane, and they use a number of distinct ‘gating’ mechanisms to open and close this pore in response to biological stimuli such as the binding of a ligand or a change in the transmembrane voltage. This review is written at a watershed in our understanding of ion channels. 1. INTRODUCTION 240 1.1 Basic structure of voltage-activated channels 241 1.2 What are the physical motions of the channel protein during gating? 243 1.3 Gating involves several distinct mechanisms of activation and inactivation 246 2. ACTIVATION GATING 246 2.1 Early evidence for an activation gate at the intracellular mouth 247 2.1.1 Open channel blockade 247 2.1.2 The ‘ foot-in-the-door’ effect 249 2.1.3 Trapping of blockers behind closed activation gates 249 2.2 Site-directed mutagenesis and the difficulty of inferring structural roles from functional effects 250 2.3 State-dependent cysteine modification as a reporter of position and motion 251 2.4 Localization of activation gating 254 2.4.1 The trapping cavity 254 2.4.2 The activation gate 255 2.4.3 Is there more than one site of activation gating? 258 3. INACTIVATION GATING 259 3.1 Ball-and-chain (N-type) inactivation 261 3.1.1 Nature of the ‘ball’ – a tethered blocking particle 262 3.1.2 The ball receptor 263 3.1.3 The chain 264 3.1.4 Variations on the N-type inactivation theme: multiple balls, foreign balls, anti-balls 265 3.2 C-type inactivation 266 3.2.1 C-type inactivation and the outer mouth of the K+channel 266 3.2.2 The selectivity filter participates in C-type inactivation 267 3.2.3 A consistent structural picture of C-type inactivation 269 3.3 By what mechanism do other voltage-gated channels inactivate? 272 4. THE VOLTAGE SENSOR 273 4.1 Quantitative principles of voltage-dependent gating 276 4.2 S4 (and its neighbours) as the principal voltage sensor 277 4.2.1 Mutational effects on voltage-dependence and charge movement 277 4.2.2 Evidence for the translocation of S4 279 4.2.3 Real-time monitoring of S4motion by fluorescence 282 4.3 Coupling between the voltage sensor and gating 283 5. CONCLUSION 284 6. ACKNOWLEDGEMENTS 287 7. REFERENCES 287

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0033583598003448

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 478

Metadata

Authors
YELLEN, G.
Venue
Quarterly Reviews of Biophysics
Published
1998-08
Volume
31
Issue
3
Pages
239-295
ISSN
  • 0033-5835 (ISSN-L)
  • 1469-8994
OpenAlex
W2122167535
Cited by
478
References
2
FWCI
8.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The moving parts of voltage-gated ion channels. https://app.cochat.ai/papers/10.1017/s0033583598003448
The paper
YELLEN, G. (1998). The moving parts of voltage-gated ion channels. Quarterly Reviews of Biophysics. https://doi.org/10.1017/s0033583598003448

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.