The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Histidine Scanning Mutagenesis of Basic Residues of the S4 Segment of the Shaker K+ Channel
Open accessAbstract
The voltage sensor of the Shaker potassium channel is comprised mostly of positively charged residues in the putative fourth transmembrane segment, S4 (Aggarwal, S.K., and R. MacKinnon. 1996. Neuron. 16:1169–1177; Seoh, S.-A., D. Sigg, D.M. Papazian, and F. Bezanilla. 1996. Neuron. 16:1159–1167). Movement of the voltage sensor in response to a change in the membrane potential was examined indirectly by measuring how the accessibilities of residues in and around the sensor change with voltage. Each basic residue in the S4 segment was individually replaced with a histidine. If the histidine tag is part of the voltage sensor, then the gating charge displaced by the voltage sensor will include the histidine charge. Accessibility of the histidine to the bulk solution was therefore monitored as pH-dependent changes in the gating currents evoked by membrane potential pulses. Histidine scanning mutagenesis has several advantages over other similar techniques. Since histidine accessibility is detected by labeling with solution protons, very confined local environments can be resolved and labeling introduces minimal interference of voltage sensor motion. After histidine replacement of either residue K374 or R377, there was no titration of the gating currents with internal or external pH, indicating that these residues do not move in the transmembrane electric field or that they are always inaccessible. Histidine replacement of residues R365, R368, and R371, on the other hand, showed that each of these residues traverses entirely from internal exposure at hyperpolarized potentials to external exposure at depolarized potentials. This translocation enables the histidine to transport protons across the membrane in the presence of a pH gradient. In the case of 371H, depolarization drives the histidine to a position that forms a proton pore. Kinetic models of titrateable voltage sensors that account for proton transport and conduction are presented. Finally, the results presented here are incorporated into existing information to propose a model of voltage sensor movement and structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Cited by
Atomic structure of a voltage-dependent K+ channel in a lipid membrane-like environment
Long, S. B., Tao, X., Campbell, E. B., & MacKinnon, R. (2007) · Nature · doi:10.1038/nature06265 · Cited by 1,411
A Voltage Sensor-Domain Protein Is a Voltage-Gated Proton Channel
Sasaki, M., Takagi, M., & Okamura, Y. (2006) · Science · doi:10.1126/science.1122352 · Cited by 542
A proton pore in a potassium channel voltage sensor reveals a focused electric field
Starace, D. M., & Bezanilla, F. (2004) · Nature · doi:10.1038/nature02270 · Cited by 398
Self-citationA recurrent de novo mutation in KCNC1 causes progressive myoclonus epilepsy
Muona, M., Berkovic, S. F., Dibbens, L. M., Oliver, K. L., Maljevic, S., Bayly, M. A., Joensuu, T., Canafoglia, L., Franceschetti, S., Michelucci, R., et al. (2015) · Nature Genetics · doi:10.1038/ng.3144 · Cited by 298
Sensing voltage across lipid membranes
Swartz, K. J. (2008) · Nature · doi:10.1038/nature07620 · Cited by 293
Metadata
- Authors
- Starace, D. M., & Bezanilla, F.
- Venue
- The Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 2001-04-30
- Volume
- 117
- Issue
- 5
- Pages
- 469-490
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2041836266
- Cited by
- 234
- References
- 1
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Histidine Scanning Mutagenesis of Basic Residues of the S4 Segment of the Shaker K+ Channel. https://app.cochat.ai/papers/10.1085/jgp.117.5.469
- The paper
- Starace, D. M., & Bezanilla, F. (2001). Histidine Scanning Mutagenesis of Basic Residues of the S4 Segment of the Shaker K+ Channel. The Journal of General Physiology. https://doi.org/10.1085/jgp.117.5.469
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.