Pore size matters for potassium channel conductance
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Ion channels are membrane proteins that mediate efficient ion transport across the hydrophobic core of cell membranes, an unlikely process in their absence. K+ channels discriminate K+ over cations with similar radii with extraordinary selectivity and display a wide diversity of ion transport rates, covering differences of two orders of magnitude in unitary conductance. The pore domains of large- and small-conductance K+ channels share a general architectural design comprising a conserved narrow selectivity filter, which forms intimate interactions with permeant ions, flanked by two wider vestibules toward the internal and external openings. In large-conductance K+ channels, the inner vestibule is wide, whereas in small-conductance channels it is narrow. Here we raise the idea that the physical dimensions of the hydrophobic internal vestibule limit ion transport in K+ channels, accounting for their diversity in unitary conductance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interaction of Tetraethylammonium Ion Derivatives with the Potassium Channels of Giant Axons
Armstrong, C. M. (1971) · The Journal of General Physiology · doi:10.1085/jgp.58.4.413 · Cited by 929 · cited 8×
“(c) K+ ions are partially hydrated in the narrow section of the pore, as Mullins, Bezanilla, and Armstrong proposed half a century ago (Mullins, 1959; Armstrong, 1971; Bezanilla and Armstrong, 1972; Hille, 1973).”
InfluentialPARSEGIAN, A. (1969) · Nature · doi:10.1038/221844a0 · Cited by 854
Cation selective glass electrodes and their mode of operation
Eisenman, G. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86959-8 · Cited by 852 · cited 14×
“Nevertheless, because the difference in their hydration energies is ∼16 kcal/mol, removal of the hydration water should be ∼1010 harder for Na+ (Robinson and Stokes, 2002).”
Influential
Cited by
A Historical Review of Brain Drug Delivery
Pardridge, W. M. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14061283 · Cited by 219
Jeremic, D., Sanchez-Rodriguez, I., Jimenez-Diaz, L., & Navarro-Lopez, J. D. (2021) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2021.107808 · Cited by 89
Conduction pathway for potassium through the E. coli pump KdpFABC
(2025) · doi:10.1101/2025.05.05.652293 · Cited by 2
Metadata
- Authors
- Naranjo, D., Moldenhauer, H., Pincuntureo, M., & Díaz-Franulic, I.
- Venue
- The Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 2016-09-12
- Volume
- 148
- Issue
- 4
- Pages
- 277-291
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2518880905
- Cited by
- 47
- References
- 3
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pore size matters for potassium channel conductance. https://app.cochat.ai/papers/10.1085/jgp.201611625
- The paper
- Naranjo, D., Moldenhauer, H., Pincuntureo, M., & Díaz-Franulic, I. (2016). Pore size matters for potassium channel conductance. The Journal of General Physiology. https://doi.org/10.1085/jgp.201611625
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.