The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Two Fast Transient Current Components during Voltage Clamp on Snail Neurons
Open accessAbstract
Voltage clamp currents from medium sized ganglion cells of Helix pomatia have a fast transient outward current component in addition to the usually observed inward and outward currents. This component is inactivated at normal resting potential. The current, which is carried by K+ ions, may surpass leakage currents by a factor of 100 after inactivation has been removed by hyperpolarizing conditioning pulses. Its kinetics are similar to those of the inward current, except that it has a longer time constant of inactivation. It has a threshold close to resting potential. This additional component is also present in giant cells, where however, it is less prominent. Pacemaker activity is controlled by this current. It was found that inward currents have a slow inactivating process in addition to a fast, Hodgkin-Huxley type inactivation. The time constants of the slow process are similar to those of slow outward current inactivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Voltage clamp studies of a transient outward membrane current in gastropod neural somata
Connor, J. A., & Stevens, C. F. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009365 · Cited by 1,095
Prediction of repetitive firing behaviour from voltage clamp data on an isolated neurone soma
Connor, J. A., & Stevens, C. F. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009366 · Cited by 740
Frankenhaeuser, B., & Huxley, A. F. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007378 · Cited by 702
Inward and delayed outward membrane currents in isolated neural somata under voltage clamp
Connor, J. A., & Stevens, C. F. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009364 · Cited by 329
Potassium permeability in myelinated nerve fibres of Xenopus laevis
FRANKENHAEUSER, B. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006834 · Cited by 99
Oscillation and Repetitive Firing in Squid Axons
Guttman, R., & Barnhill, R. (1970) · The Journal of General Physiology · doi:10.1085/jgp.55.1.104 · Cited by 73
Current- and Voltage-Clamped Studies on Myxicola Giant Axons
Binstock, L., & Goldman, L. (1969) · The Journal of General Physiology · doi:10.1085/jgp.54.6.730 · Cited by 67
Using electronic circuits to model simple neuroelectric interactions
Lewis, E. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6445 · Cited by 61
Cited by
Structure and Function of Voltage-Sensitive Ion Channels
Catterall, W. A. (1988) · Science · doi:10.1126/science.2459775 · Cited by 1,174
Jahnsen, H., & Llinás, R. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015154 · Cited by 1,078
Grace, A., & Onn, S. (1989) · The Journal of Neuroscience · doi:10.1523/jneurosci.09-10-03463.1989 · Cited by 718
Hoshi, T., Zagotta, W. N., & Aldrich, R. W. (1991) · Neuron · doi:10.1016/0896-6273(91)90367-9 · Cited by 694
Three pharmacologically distinct potassium channels in molluscan neurones.
Thompson, S. H. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011725 · Cited by 677
Metadata
- Authors
- Neher, E.
- Venue
- The Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 1971-07-01
- Volume
- 58
- Issue
- 1
- Pages
- 36-53
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2031920967
- Cited by
- 420
- References
- 9
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.