The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Slow PIII component of the carp electroretinogram.
Open accessAbstract
The slow PIII component of the electroretinogram (ERG) was studied in the isolated, aspartate-treated carp retina. Although the latter is richly populated with cones, slow PIII appeared to reflect almost exclusively the activity of rods; e.g. the spectral sensitivity of the potential paralleled closely the rod pigment curve, its operating range (i.e. the V-log I curve) was limited to 3 log units above absolute threshold, and raising background intensities to photopic levels produced saturation of the increment threshold function without evidence of a cone-mediated segment. Only after bleaching away a significant fraction of the porphyropsin was it possible to unmask a small photopic contribution to slow PIII, as evidenced by a displacement in the action spectrum to longer wavelengths. The spatial distribution of the slow PIII voltage within the retina (Faber, D.S. 1969. Ph.D. Thesis. State University of New York. Buffalo, N.Y.; Witkovsky, P.J. Nelson, and H. Ripps. 1973. J. Gen Physiol. 61:401) and its ability to survive aspartate treatment indicate that this potential arises in the Müller (glial) fiber. Additional support for this conclusion is provided by the slow rise time (several seconds) and long temporal integration (up to 40s) of the response. In many respects the properties of slow PIII resemble those of the c-wave, a pigment epithelial response also subserved by rod activity. On the other hand, the receptoral (fast PIII) and the b-wave components of the ERG behave quite differently. Unlike slow PIII, response saturation could not be induced, since both potentials are subserved by cones when the stimulus conditions exceed the limits of the scotopic range. Receptors appear to govern light adaptation at photopic background levels; both fast PIII and b-wave manifest identical incremental threshold values over this range of intensities. However, under scotopic conditions, the sensitivity of the b-wave is affected by luminous backgrounds too weak to alter fast PIII threshold, indicating a postreceptoral stage of adaptation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The electroretinogram: Its components and their origins
Brown, K. T. (1968) · Vision Research · doi:10.1016/0042-6989(68)90041-2 · Cited by 558 · cited 1×
“Brown caused the disappearance of the b-wave through interruption of the retinal circulation that nourishes the inner retinal layers, while the reeeptoral component of the ERG remained (reviewed in Brown, 1968).”
Background
Cited by
Oscillatory potentials in the retina: what do they reveal
Wachtmeister, L. (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00006-8 · Cited by 529
Kofuji, P., Ceelen, P., Zahs, K. R., Surbeck, L. W., Lester, H. A., & Newman, E. A. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-15-05733.2000 · Cited by 461
B-wave of the electroretinogram. A reflection of ON bipolar cell activity
Stockton, R. A., & Slaughter, M. M. (1989) · The Journal of general physiology · doi:10.1085/jgp.93.1.101 · Cited by 446
Sieving, P. A., Murayama, K., & Naarendorp, F. (1994) · Visual Neuroscience · doi:10.1017/s0952523800002431 · Cited by 388
Sensitivity of toad rods: Dependence on wave‐length and background illumination.
Fain, G. L. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011549 · Cited by 262
Zhang, C., Miyagishima, K. J., Dong, L., Rising, A., Nimmagadda, M., Liang, G., Sharma, R., Dejene, R., Wang, Y., Abu-Asab, M., et al. (2019) · Human Molecular Genetics · doi:10.1093/hmg/ddz171 · Cited by 26
“1 inwardly rectifying potassium (K) channels and (2) a slower, negative PIII component generated by inner retinal neurons (49).”
Background
Metadata
- Authors
- Witkovsky, P., Dudek, F. E., & Ripps, H.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1975-02-01
- Volume
- 65
- Issue
- 2
- Pages
- 119-134
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W1964383367
- Cited by
- 170
- References
- 1
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.