The DOI matches its Crossref record.
Steady-state current-voltage relationship of the Na/K pump in guinea pig ventricular myocytes.
Open accessAbstract
Whole-cell currents were recorded in guinea pig ventricular myocytes at approximately 36 degrees C before, during, and after exposure to maximally effective concentrations of strophanthidin, a cardiotonic steroid and specific inhibitor of the Na/K pump. Wide-tipped pipettes, in combination with a device for exchanging the solution inside the pipette, afforded reasonable control of the ionic composition of the intracellular solution and of the membrane potential. Internal and external solutions were designed to minimize channel currents and Na/Ca exchange current while sustaining vigorous forward Na/K transport, monitored as strophanthidin-sensitive current. 100-ms voltage pulses from the -40 mV holding potential were used to determine steady-state levels of membrane current between -140 and +60 mV. Control experiments demonstrated that if the Na/K pump cycle were first arrested, e.g., by withdrawal of external K, or of both internal and external Na, then neither strophanthidin nor its vehicle, dimethylsulfoxide, had any discernible effect on steady-state membrane current. Further controls showed that, with the Na/K pump inhibited by strophanthidin, membrane current was insensitive to changes of external [K] between 5.4 and 0 mM and was little altered by changing the pipette [Na] from 0 to 50 mM. Strophanthidin-sensitive current therefore closely approximated Na/K pump current, and was virtually free of contamination by current components altered by the changes in extracellular [K] and intracellular [Na] expected to accompany pump inhibition. The steady-state Na/K pump current-voltage (I-V) relationship, with the pump strongly activated by 5.4 mM external K and 50 mM internal Na (and 10 mM ATP), was sigmoid in shape with a steep positive slope between about 0 and -100 mV, a less steep slope at more negative potentials, and an extremely shallow slope at positive potentials; no region of negative slope was found. That shape of I-V relationship can be generated by a two-state cycle with one pair of voltage-sensitive rate constants and one pair of voltage-insensitive rate constants: such a two-state scheme is a valid steady-state representation of a multi-state cycle that includes only a single voltage-sensitive step.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dynamics and Consequences of Potassium Shifts in Skeletal Muscle and Heart During Exercise
Sejersted, O. M., & Sjøgaard, G. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.4.1411 · Cited by 490
Su, G., Kintner, D. B., Flagella, M., Shull, G. E., & Sun, D. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00538.2001 · Cited by 169
The establishment and maintenance of corneal transparency
Stiernke, M. (1995) · Progress in Retinal and Eye Research · doi:10.1016/1350-9462(93)e0011-r · Cited by 17
Metadata
- Authors
- Gadsby, D. C., & Nakao, M.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1989-09-01
- Volume
- 94
- Issue
- 3
- Pages
- 511-537
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2029193464
- Cited by
- 216
- References
- 0
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Steady-state current-voltage relationship of the Na/K pump in guinea pig ventricular myocytes. https://app.cochat.ai/papers/10.1085/jgp.94.3.511
- The paper
- Gadsby, D. C., & Nakao, M. (1989). Steady-state current-voltage relationship of the Na/K pump in guinea pig ventricular myocytes. The Journal of general physiology. https://doi.org/10.1085/jgp.94.3.511
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.