The DOI matches its Crossref record.
Oxygen distribution and consumption in the cat retina during normoxia and hypoxemia.
Open accessAbstract
Oxygen tension (PO2) was measured with microelectrodes within the retina of anesthetized cats during normoxia and hypoxemia (i.e., systemic hypoxia), and photoreceptor oxygen consumption was determined by fitting PO2 measurements to a model of steady-state oxygen diffusion and consumption. Choroidal PO2 fell linearly during hypoxemia, about 0.64 mmHg/mmHg decrease in arterial PO2 (PaO2). The choroidal circulation provided approximately 91% of the photoreceptors' oxygen supply under dark-adapted conditions during both normoxia and hypoxemia. In light adaptation the choroid supplied all of the oxygen during normoxia, but at PaO2's less than 60 mmHg the retinal circulation supplied approximately 10% of the oxygen. In the dark-adapted retina the decrease in choroidal PO2 caused a large decrease in photoreceptor oxygen consumption, from approximately 5.1 ml O2/100 g.min during normoxia to 2.6 ml O2/100 g.min at a PaO2 of 50 mmHg. When the retina was adapted to a rod saturating background, normoxic oxygen consumption was approximately 33% of the dark-adapted value, and hypoxemia caused almost no change in oxygen consumption. This difference in metabolic effects of hypoxemia in light and dark explains why the standing potential of the eye and retinal extracellular potassium concentration were previously found to be more affected by hypoxemia in darkness. Frequency histograms of intraretinal PO2 were used to characterize the oxygenation of the vascularized inner half of the retina, where the oxygen distribution is heterogeneous and simple diffusion models cannot be used. Inner retinal PO2 during normoxia was relatively low: 18 +/- 12 mmHg (mean and SD; n = 8,328 values from 36 profiles) in dark adaptation, and significantly lower, 13 +/- 6 mmHg (n = 4,349 values from 19 profiles) in light adaptation. Even in the dark-adapted retina, 30% of the values were less than 10 mmHg. The mean PO2 in the inner (i.e., proximal) half of the retina was well regulated during hypoxemia. In dark adaptation it was significantly reduced only at PaO2's less than 45 mmHg, and it was reduced less at these PaO2's in light adaptation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sommermeyer, D., Hudecek, M., Kosasih, P. L., Gogishvili, T., Maloney, D. G., Turtle, C. J., & Riddell, S. R. (2016) · Leukemia · doi:10.1038/leu.2015.247 · Cited by 867
McDougal, D. H., & Gamlin, P. D. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c140014 · Cited by 428
Braun, R. D., Lanzen, J. L., Snyder, S. A., & Dewhirst, M. W. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.6.h2533 · Cited by 285
Self-citationOxygen Sensing in Retinal Health and Disease
Lange, C. A. K., & Bainbridge, J. W. B. (2012) · Ophthalmologica · doi:10.1159/000331418 · Cited by 86
Metadata
- Authors
- Linsenmeier, R. A., & Braun, R. D.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1992-02-01
- Volume
- 99
- Issue
- 2
- Pages
- 177-197
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2112479900
- Cited by
- 257
- References
- 0
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen distribution and consumption in the cat retina during normoxia and hypoxemia. https://app.cochat.ai/papers/10.1085/jgp.99.2.177
- The paper
- Linsenmeier, R. A., & Braun, R. D. (1992). Oxygen distribution and consumption in the cat retina during normoxia and hypoxemia. The Journal of general physiology. https://doi.org/10.1085/jgp.99.2.177
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.