Limitations of Forehead Infrared Body Temperature Detection for Fever Screening for Severe Acute Respiratory Syndrome
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We investigated alternative measurement methodology for infrared body thermometry to increase accuracy for outdoor fever screening during the 2003 SARS epidemic. Our results indicate that the auditory meatus temperature is a superior alternative compared with the forehead body surface temperature due to its close approximation to the tympanic temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of a novel coronavirus in patients with severe acute respiratory syndrome
Drosten, C., Günther, S., Preiser, W., van der Werf, S., Brodt, H.-R., Becker, S., Rabenau, H., Panning, M., Kolesnikova, L., Fouchier, R. A. M., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa030747 · Cited by 4,574
Seto, W., Tsang, D., Yung, R., Ching, T., Ng, T., Ho, M., Ho, L., & Peiris, J. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13168-6 · Cited by 863
Cited by
Bitar, D., Goubar, A., & Desenclos, J. C. (2009) · Eurosurveillance · doi:10.2807/ese.14.06.19115-en · Cited by 150
“This target area yielded higher sensitivity results than the forehead: 82.7% vs. 17.3% [ 14 ] and 67.0% vs. 4.0% [11], respectively.”
BackgroundMethodResultInfluentialChen, H.-Y., Chen, A., & Chen, C. (2020) · Sensors · doi:10.3390/s20102885 · Cited by 139
Khaksari, K., Nguyen, T., Hill, B. Y., Perrault, J., Gorti, V., Blick, E., Gonzalez Cano, T., Shadgan, B., Quang, T., Malpani, R., et al. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.s1.010901 · Cited by 55
“Other studies focused on forehead or auditory meatus temperature for easier measurement, but limitations are reported.(84) Ultimately, the lack of scientific data showing the relationship between human head (face) temperature and core body temperature remains a challenge to be addressed.”
BackgroundWang, Q., Zhou, Y., Ghassemi, P., McBride, D., Casamento, J. P., & Pfefer, T. J. (2021) · Sensors · doi:10.3390/s22010215 · Cited by 48
“The skin temperature at this location tends to be sensiti e to environmental factors such as ambient temperature and airflow, which may degrade correlation with core/oral temperature [23].”
BackgroundInfluentialNon-contact infrared assessment of human body temperature: The journal Temperature toolbox
Foster, J., Lloyd, A. B., & Havenith, G. (2021) · Temperature · doi:10.1080/23328940.2021.1899546 · Cited by 46
“Assessing Tforehead in an outdoor/uncontrolled setting yields poor performance metrics and is not suitable for fever screening or tracking Tcore marked by a high false negative rate (low sensitivity) [63].”
Background
Metadata
- Authors
- Liu, C.-C., Chang, R.-E., & Chang, W.-C.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2004-12
- Volume
- 25
- Issue
- 12
- Pages
- 1109-1111
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2104076078
- Cited by
- 95
- References
- 2
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.