Relationship between Bacterial Load, Species Virulence, and Transfusion Reaction with Transfusion of Bacterially Contaminated Platelets
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Bacterial contamination is currently the major infectious hazard of platelet transfusion, but associations between bacterial species and quantity and transfusion reactions have not been characterized. METHODS: Patients receiving platelets from July 1991 through December 2006 were observed using active surveillance by quantitative culture of platelets at the time of issue or passive surveillance by investigation of clinical reactions in patients and culture of implicated units. Patient reactions were classified by type and severity and were correlated with bacterial species and number. Endotoxin content of gram-negative contaminants was determined by limulus lysate assay. RESULTS: Fifty-two bacterially contaminated platelet units were detected (50 by active and 2 by passive surveillance). Rates of bacterial contamination and septic transfusion reactions were 32.0-fold and 10.6-fold higher, respectively, as determined by active versus passive surveillance (P < .001). Including 2 index cases, bacterial contaminants included gram-negative bacilli in 4 units (3 of which were associated with fatal reactions), staphylococci in 44 units, streptococci in 4 units, and Bacillus cereus in 2 units. Endotoxin content of the 4 units that were contaminated with gram-negative bacilli ranged from 11,373 to 173,130 endotoxin units. Reaction severity was greater for units with bacterial counts of > or =10(5) colony-forming units/mL and higher bacterial virulence. A detection method with a 10(3) colony-forming units/mL threshold would detect >90% of contaminants. CONCLUSIONS: Active surveillance detected 32-fold more bacterially contaminated platelet units and 10.6-fold more septic reactions than did passive surveillance, and virulent species and bacterial counts of > or =10(5) colony-forming units/mL were associated with more-severe transfusion reactions. Improved detection methods or use of pathogen inactivation technology are needed to eliminate this problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma Cytokine and Endotoxin Levels Correlate with Survival in Patients with the Sepsis Syndrome
Casey, L. C., Balk, R. A., & Bone, R. C. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-119-8-199310150-00001 · Cited by 1,041 · cited 1×
“A study of patients with septic shock showed median plasma endotoxin loads of 13,000 EU [13], and a self-administered intravenous endotoxin dose of 1 mg (100,000 EU) resulted in shock and multiple-organ dysfunction in a patient [14].”
BackgroundBacterial Contamination of Blood Components
Brecher, M. E., & Hay, S. N. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.1.195-204.2005 · Cited by 418
Immunodeficiency Diseases Caused by Defects in Phagocytes
Lekstrom-Himes, J. A., & Gallin, J. I. (2000) · New England Journal of Medicine · doi:10.1056/nejm200012073432307 · Cited by 390 · cited 1×
“marcescens in a neonate with congenital neutropenia who received the largest amount of endotoxin (173,130 EU), and deficiency in or desensitization of phagocytic effector cells or defects in the IFN-g–IL-12 axis may explain the lack of response and survival of this patient [15].”
BackgroundTransfusion‐transmitted bacterial infectionin the United States, 1998 through 2000
Kuehnert, M. J., Roth, V. R., Haley, N. R., Gregory, K. R., Elder, K. V., Schreiber, G. B., Arduino, M. J., Holt, S. C., Carson, L. A., Banerjee, S. N., et al. (2001) · Transfusion · doi:10.1046/j.1537-2995.2001.41121493.x · Cited by 378
American Association of Blood Banks
Greenwalt, T. J. (1959) · Vox Sanguinis · doi:10.1159/000478446 · Cited by 293
Shock and Multiple-Organ Dysfunction after Self-Administration of Salmonella Endotoxin
da Silva, A. M. T., Kaulbach, H. C., Chuidian, F. S., Lambert, D. R., Suffredini, A. F., & Danner, R. L. (1993) · New England Journal of Medicine · doi:10.1056/nejm199305203282005 · Cited by 276 · cited 1×
“A study of patients with septic shock showed median plasma endotoxin loads of 13,000 EU [13], and a self-administered intravenous endotoxin dose of 1 mg (100,000 EU) resulted in shock and multiple-organ dysfunction in a patient [14].”
BackgroundMcDonald, C. P., Roy, A., Mahajan, P., Smith, R., Charlett, A., & Barbara, J. A. J. (2004) · Vox Sanguinis · doi:10.1111/j.0042-9007.2004.00404.x · Cited by 111
Nussbaumer, W., Allersdorfer, D., Grabmer, C., Rheinschmidt, M., Lin, L., Schönitzer, D., & Lass‐Flörl, C. (2007) · Transfusion · doi:10.1111/j.1537-2995.2007.01247.x · Cited by 51 · cited 1×
“The second proposed solution is to use pathogen inactivation technology, which also obviates the need for bacterial detection, and although regulatory approval has been received in Europe, this is not likely to occur in the United States in the next few years [22].”
MethodSevere vagal response after endotoxin administration in humans
van Eijk, L. T. G. J., Pickkers, P., Smits, P., Bouw, M. P. W. J. M., & van der Hoeven, J. G. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2477-0 · Cited by 44 · cited 1×
“In the previous 3 decades, small doses of endotoxin (2–4 ng/ kg, equivalent to 14–28 EU in a 70-kg adult), administered intravenously to thousands of volunteers to study acute inflammatory responses, have generally been found to be safe, although 4 cases of severe bradycardia or protracted asystole have been reported…”
BackgroundLundy, D., Laspina, S., Kaplan, H., Fastman, B. R., & Lawlor, E. (2007) · Vox Sanguinis · doi:10.1111/j.1423-0410.2006.00885.x · Cited by 44 · cited 1×
“There is also a need for a national hemovigilance system for adverse events from blood product use in the United States [18], an approach that has been successfully used in other countries to coordinate the recognition and documentation of transfusion-associated adverse events and, thereby, to improve the overall safe…”
BackgroundProwse, C. (2007) · Transfusion · doi:10.1111/j.1537-2995.2007.01322.x · Cited by 20
Yomtovían, R., Tomasulo, P., & Jacobs, M. R. (2007) · Transfusion · doi:10.1111/j.1537-2995.2007.01402.x · Cited by 16 · cited 1×
“The first is to increase the sensitivity of bacterial detection performed at 24 h by increasing the volume cultured or performing the culture at a later time [21].”
BackgroundSelf-citation
Metadata
- Authors
- Jacobs, M. R., Good, C. E., Lazarus, H. M., & Yomtovian, R. A.
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-04-15
- Volume
- 46
- Issue
- 8
- Pages
- 1214-1220
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2160134158
- Cited by
- 177
- References
- 12
- FWCI
- 5.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.