Limitations of the Efficacy of Surface Disinfection in the Healthcare Setting
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We examined the efficacy of 2 commercially available wipes to effectively remove, kill, and prevent the transfer of both methicillin-resistant and methicillin-susceptible Staphylococcus aureus from contaminated surfaces. Although wipes play a role in decreasing the number of pathogenic bacteria from contaminated surfaces, they can potentially transfer bacteria to other surfaces if they are reused.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the inappropriate reuse of the towelette may promote the accumulation of microorganisms and raise the risk of cross-contamination during the disinfection process [63–65].”
From Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review (2019) · cites this paper as [63]
Citations
Cites
How long do nosocomial pathogens persist on inanimate surfaces? A systematic review
Kramer, A., Schwebke, I., & Kampf, G. (2006) · BMC Infectious Diseases · doi:10.1186/1471-2334-6-130 · Cited by 2,504
Sehulster, L. M., & Chinn, R. Y. W. (2003) · PubMed · Cited by 1,710
Coia, J. E., Duckworth, G. J., Edwards, D. I., Farrington, M., Fry, C., Humphreys, H., Mallaghan, C., & Tucker, D. R. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.01.001 · Cited by 544 · cited 2×
“The use of surface disinfectants as a preventive measure is therefore of prime importance, and the efficacy of these agents needs to be ensured as part of the overall strategy to control healthcareacquired infection.(3) Disinfection regimens adopted in intensive therapy units (ITUs) and healthcare facilities in Wales…”
BackgroundBarker, J., Vipond, I. B., & Bloomfield, S. F. (2004) · Journal of Hospital Infection · doi:10.1016/j.jhin.2004.04.021 · Cited by 407
Routine disinfection of patients’ environmental surfaces. Myth or reality?
Dharan, S., Mourouga, P., Copin, P., Bessmer, G., Tschanz, B., & Pittet, D. (1999) · Journal of Hospital Infection · doi:10.1053/jhin.1999.0567 · Cited by 146
Coia, J. E., Duckworth, G., Edwards, D., Farrington, M. M., Fry, C., Humphreys, H., Mallaghan, C., & Tucker, D. R. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.06.001 · Cited by 122
Kampf, G., Jarosch, R., & Rüden, H. (1998) · Journal of Hospital Infection · doi:10.1016/s0195-6701(98)90078-0 · Cited by 117 · cited 1×
“Finally, some reports have suggested that MRSA might be more resilient than MSSA to disinfection (eg, to chlorhexidine-based solutions).(9,10) In our study, we found no difference in susceptibility or resistance between MSSA and MRSA with regard to surface disinfection.”
BackgroundBlock, C., Robenshtok, E., Simhon, A., & Shapiro, M. (2000) · Journal of Hospital Infection · doi:10.1053/jhin.2000.0805 · Cited by 84 · cited 1×
“Finally, some reports have suggested that MRSA might be more resilient than MSSA to disinfection (eg, to chlorhexidine-based solutions).(9,10) In our study, we found no difference in susceptibility or resistance between MSSA and MRSA with regard to surface disinfection.”
BackgroundWilliams, G. J., Denyer, S. P., Hosein, I. K., Hill, D. W., & Maillard, J.-Y. (2007) · Journal of Hospital Infection · doi:10.1016/j.jhin.2007.08.012 · Cited by 57
Self-citationContamination of detergent cleaning solutions during hospital cleaning
Werry, C., Lawrence, J. M., & Sanderson, P. J. (1988) · Journal of Hospital Infection · doi:10.1016/0195-6701(88)90038-2 · Cited by 23 · cited 2×
“Simple cleaning regimens alone might be ineffective at eliminating microbial contamination.(4)"(6) The use of surface disinfectants as a preventive measure is therefore of prime importance, and the efficacy of these agents needs to be ensured as part of the overall strategy to control healthcareacquired infection.”
Background
Cited by
Biocide Use in the Antimicrobial Era: A Review
Jones, I. A., & Joshi, L. T. (2021) · Molecules · doi:10.3390/molecules26082276 · Cited by 192
“[18], who established that although the QAC-formulated Clinell Universal Sanitizing Wipes had effective biocidal properties against surfaces loaded with Methicillin-resistant Staphylococcus aureus (MRSA) and Methicillin-sensitive Staphylococcus aureus (MSSA), these Gram-positive bacteria were able to survive on the wi…”
BackgroundCasini, B., Tuvo, B., Cristina, M. L., Spagnolo, A. M., Totaro, M., Baggiani, A., & Privitera, G. P. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16193572 · Cited by 185
“Improper use of wipes could spread potential pathogens across surfaces if a “1 wipe, 1 application” per surface policy is not adopted [37].”
BackgroundResistance of Bacteria to Biocides
Maillard, J.-Y. (2018) · Microbiology Spectrum · doi:10.1128/microbiolspec.arba-0006-2017 · Cited by 144
“This newly found appreciation for controlling microbial pathogens on surfaces has led to an explosion of surface disinfection products and their marketing (16 – 18), contributing to a higher concentration of biocides eventually released in the environment.”
BackgroundSelf-citationCastaño, N., Cordts, S. C., Jalil, M. K., Zhang, K. S., Koppaka, S., Bick, A., Paul, R., & Tang, S. K. Y. (2021) · ACS Omega · doi:10.1021/acsomega.0c06335 · Cited by 159
Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review
Song, X., Vossebein, L., & Zille, A. (2019) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-019-0595-2 · Cited by 132
“As indicated in the aforementioned method, 209 improper reuse of the towelette can result in cross-transmission of pathogens on the treated 210 surfaces [63-65].”
Sattar, S. A., & Maillard, J. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2012.10.032 · Cited by 119
“Whereas Williams et al.(4,5) compared the efficacy of different commercially available towelettes against MRSA, Panousi et al(11) compared the efficacy of prewetted towelettes with that of disinfectant spray-on towelettes.”
Self-citationContribution of Spores to the Ability of Clostridium difficile To Adhere to Surfaces
Joshi, L. T., Phillips, D. S., Williams, C. F., Alyousef, A. A., & Baillie, L. W. J. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.01862-12 · Cited by 86
“Shown is the transfer apparatus used to assess spore transfer from stainless steel (38).”
MethodBest practice in healthcare environment decontamination
Siani, H., & Maillard, J. (2014) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-014-2205-9 · Cited by 81
“This can lead to the use of wipes that might not be appropriate for applications in the healthcare environment [132, 133].”
Self-citationPathogen transfer and high variability in pathogen removal by detergent wipes
Ramm, L., Siani, H., Wesgate, R., & Maillard, J. (2015) · American Journal of Infection Control · doi:10.1016/j.ajic.2015.03.024 · Cited by 74
Self-citationSattar, S. A. (2010) · American Journal of Infection Control · doi:10.1016/j.ajic.2010.04.207 · Cited by 72
Sattar, S. A., Bradley, C., Kibbee, R., Wesgate, R., Wilkinson, M. A. C., Sharpe, T., & Maillard, J.-Y. (2015) · Journal of Hospital Infection · doi:10.1016/j.jhin.2015.08.026 · Cited by 70
“During routine wiping, DPW may dislodge localized contamination on HTES and transfer it to neighbouring areas being wiped, posing a substantial threat to the spread of pathogenic bacteria.(14) Table III shows the total number of carriers used in the study (all laboratories combined), the number of carriers with recove…”
BackgroundMethodInfluentialSelf-citationEfficacy of “sporicidal” wipes against Clostridium difficile
Siani, H., Cooper, C., & Maillard, J.-Y. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.006 · Cited by 66
Self-citationSexton, J. D., Tanner, B. D., Maxwell, S. L., & Gerba, C. P. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2010.11.009 · Cited by 64
Raguse, M., Fiebrandt, M., Stapelmann, K., Madela, K., Laue, M. M., Lackmann, J., Thwaite, J. E., Setlow, P., Awakowicz, P., & Moeller, R. (2016) · Applied and Environmental Microbiology · doi:10.1128/aem.03934-15 · Cited by 61
“Thus, decontamination is a crucial step to ensure the sterility of food processing equipment, minimize spread of pathogens, and prevent the transmission of nosocomial infections (4).”
BackgroundLei, H., Jones, R. M., & Li, Y. (2017) · BMC Infectious Diseases · doi:10.1186/s12879-016-2120-z · Cited by 55
Raguse, M., Fiebrandt, M., Denis, B., Stapelmann, K., Eichenberger, P., Driks, A., Eaton, P. J., Awakowicz, P., & Moeller, R. (2016) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/49/28/285401 · Cited by 52
“Most conventional methods introduce some degree of damage to the treated material or medium by elevated temperatures or aggressive chemicals, making these methods suboptimal in many instances [9].”
BackgroundPlipat, N., Spicknall, I. H., Koopman, J. S., & Eisenberg, J. N. S. (2013) · BMC Infectious Diseases · doi:10.1186/1471-2334-13-595 · Cited by 51
Djouiai, B., Thwaite, J. E., Laws, T. R., Commichau, F. M., Setlow, B., Setlow, P., & Moeller, R. (2018) · Applied and Environmental Microbiology · doi:10.1128/aem.01604-18 · Cited by 42
“Spores of various species are also a major concern for the medical product, food, and health care industries, as spores cause much food spoilage and human disease and are very resistant to decontamination regimens that readily kill vegetative bacteria (4).”
BackgroundCadnum, J. L., Hurless, K. N., Kundrapu, S., & Donskey, C. J. (2013) · Infection Control & Hospital Epidemiology · doi:10.1086/669871 · Cited by 34
“Transfer of spores was evaluated using a modification of the method of Williams et al.(8,9) A clean bench top surface was inoculated with 5 log10 colony-forming unit (CFU) aliquots of C.”
MethodEvaluation of a Disinfectant Wipe Intervention on Fomite-to-Finger Microbial Transfer
Lopez, G. U., Kitajima, M., Havas, A., Gerba, C. P., & Reynolds, K. A. (2014) · Applied and Environmental Microbiology · doi:10.1128/aem.04235-13 · Cited by 34
“(29) and found results similar to those of the present study, showing microbial reduction on fomites after wiping with a disinfectant wipe (22, 29, 30, 49).”
MethodResultXiao, S., Jones, R. M., Zhao, P., & Li, Y. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106246 · Cited by 34
Kenters, N., Huijskens, E. G. W., de Wit, S. C. J., Sanders, I. M. J. G., van Rosmalen, J., Kuijper, E. J., & Voss, A. (2017) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-017-0210-3 · Cited by 31
“63, which is exactly within the range of difference we observed with wipes and sprays [22, 23].”
BackgroundHow Does a Photocatalytic Antimicrobial Coating Affect Environmental Bioburden in Hospitals?
Reid, M., Whatley, V., Spooner, E., Nevill, A. M., Cooper, M., Ramsden, J. J., & Dancer, S. J. (2018) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2017.297 · Cited by 29
“”(36) Detailed investigation of routine processes may reveal weaknesses, in addition to those already discussed, alongside their irreducible intermittency.(9,37) In contrast, a photocatalytic surface is continuously active.”
BackgroundVirucidal Activity of Microbicides
Maillard, J., Sattar, S. A., & Pinto, F. (2012) · Wiley-Blackwell eBooks · doi:10.1002/9781118425831.ch9 · Cited by 23
Self-citationSiani, H., Wesgate, R., & Maillard, J. (2018) · American Journal of Infection Control · doi:10.1016/j.ajic.2018.03.020 · Cited by 23
Self-citationEdwards, N. W. M., Best, E. L., Goswami, P., Wilcox, M. H., & Russell, S. J. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21249659 · Cited by 20
“Based on these data, combined with other reported studies on the performance of commercial wipes [1,21], it is apparent that the transfer of bacteria from wipes to previously sterile surfaces is highly likely regardless of conditions.”
ResultLopez, G. U. (2013) · UA Campus Repository (The University of Arizona) · Cited by 18
Potential for nosocomial transmission of Enterococcus faecalis from surfaces in dental operatories
Vidana, R., Sillerström, E., Ahlquist, M. L., & Lund, B. K. (2014) · International Endodontic Journal · doi:10.1111/iej.12342 · Cited by 16
Laboratory efficacy of surface disinfection using chlorine against Vibrio cholerae
String, G. M., Gutiérrez, E. V., & Lantagne, D. (2020) · Journal of Water and Health · doi:10.2166/wh.2020.199 · Cited by 15
Resistance of Bacteria to Biocides
Maillard, J. (2018) · ASM Press eBooks · doi:10.1128/9781555819804.ch6 · Cited by 15
Self-citationFactors Affecting the Activities of Microbicides
Maillard, J. (2012) · Wiley-Blackwell eBooks · doi:10.1002/9781118425831.ch3 · Cited by 15
Self-citationPhillips, M. (2015) · Elsevier eBooks · doi:10.1016/b978-1-4557-4801-3.00224-1 · Cited by 14
Bagattini, M., Buonocore, R., Giannouli, M., Mattiacci, D. M., Bellopede, R., Grimaldi, N., Nardone, A., Zarrilli, R., & Triassi, M. (2015) · BMC Research Notes · doi:10.1186/s13104-015-1534-9 · Cited by 13
“In contrast, the steam vapour device depends on heat for efficacy and the presence of organic matter does not influence the effectiveness [28].”
BackgroundRobertson, A., Barrell, M., & Maillard, J. (2019) · Journal of Hospital Infection · doi:10.1016/j.jhin.2019.05.005 · Cited by 13
Self-citationEmergence of bacterial resistance to microbicides and antibiotics
Maillard, J. (2010) · Microbiology Australia · doi:10.1071/ma10159 · Cited by 13
Self-citationEVALUATION OF THREE SURFACE FRICTION TECHNIQUES FOR THE REMOVAL OF ORGANIC MATTER
Rigotti, M. A., Ferreira, A. M., Nogueira, M. C. L., de Almeida, M. T. G., Guerra, O. G., & de Andrade, D. (2015) · Texto & Contexto - Enfermagem · doi:10.1590/0104-0707201500003690014 · Cited by 12
Mechanical Wiping Increases the Efficacy of Liquid Disinfectants on SARS-CoV-2
Sloan, A. M., Kasloff, S., & Cutts, T. A. (2022) · Frontiers in Microbiology · doi:10.3389/fmicb.2022.847313 · Cited by 11
“The effect of combining microbicidal actives and mechanical wiping action on the inactivation of viruses and bacteria has been evaluated in several studies (Tebbutt, 1988; Threlkeld et al., 1993; Williams et al., 2009; Abreu et al., 2013; Lopez et al., 2014; ASTM International-E2967-15, 2015; Ramm et al., 2015; Sattar…”
BackgroundMultifactorial resistance of Bacillus subtilis spores to low-pressure plasma sterilization
Muratov, E., Rosenbaum, F. P., Fuchs, F. M., Ulrich, N. J., Awakowicz, P., Setlow, P., & Moeller, R. (2023) · Applied and Environmental Microbiology · doi:10.1128/aem.01329-23 · Cited by 11
“A variety of commercial disinfection methods are used to inactivate spores, but there are limitations due to corrosive, uneconomic, or hazardous properties (23).”
BackgroundSusceptibility of Salmonella enterica Typhimurium dry surface biofilms to disinfection
Duggan, K., Shepherd, M., & Maillard, J. (2024) · Journal of Food Safety · doi:10.1111/jfs.13117 · Cited by 12
“Siani et al., 2011; Williams et al., 2009).”
Self-citationCross-contamination by disinfectant towelettes varies by product chemistry and strain
Voorn, M. G., Goss, S., Nkemngong, C. A., Li, X., Teska, P. J., & Oliver, H. F. (2020) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-020-00797-4 · Cited by 10
The Influence of Simulated Organic Matter on the Inactivation of Viruses: A Review
Allingham, C., Taniguchi, M., Kinchla, A. J., & Moore, M. D. (2024) · Viruses · doi:10.3390/v16071026 · Cited by 7
He, H., Liou, S.-Y., Shimabuku, K. K., Zhou, P., Choi, Y., Meschke, J. S., Roberts, M. C., Lee, Y., & Dodd, M. C. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.4c10223 · Cited by 7
Methicillin-Resistant Staphylococcus aureus (MRSA) Exposure Assessment in Hospital Environment.
Plipat, N. (2012) · Deep Blue (University of Michigan) · Cited by 6
Wesgate, R., & Maillard, J. (2026) · Journal of Food Protection · doi:10.1016/j.jfp.2026.100700 · Cited by 4
Self-citationWilliams, G. J. (2012) · Wiley-Blackwell eBooks · doi:10.1002/9781118425831.ch20a · Cited by 4
Self-citationBiocides in the health industry
Merlino, J., & Brown, M. H. (2010) · Microbiology Australia · doi:10.1071/ma10158 · Cited by 3
Neonatal resuscitation equipment: A hidden risk for our babies?
Winckworth, L. C., McLaren, E., Lingeswaran, A., & Kelsey, M. C. (2016) · Journal of Paediatrics and Child Health · doi:10.1111/jpc.13150 · Cited by 2
Snider, K. A. (2012) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 2
Study on Ionic Wind of Bipolar Corona and Its Sterilization Effect
Liu, S., Han, R., Zhang, C., Wang, M., Zhang, T., & Ouyang, J. (2020) · IEEE International Conference on High Voltage Engineering and Application (ICHVE) · doi:10.1109/ichve49031.2020.9279649 · Cited by 2
“However, traditional sterilization methods have many disadvantages, such as affecting the physical and biological properties of medical devices, high temperature, long duration and unsafety [1-3].”
BackgroundAllen, M. J. (2016) · Queensland University of Technology · doi:10.5204/thesis.eprints.99603 · Cited by 2
Microbicides - The Double-Edged Sword: Environmental Toxicity and Emerging Resistance
Pagès, J., Maillard, J., Davin‐Regli, A., & Springthorpe, S. (2012) · Wiley-Blackwell eBooks · doi:10.1002/9781118425831.ch11 · Cited by 1
Self-citationBednarsh, H., Eklund, K., & Cuny, E. J. (2014) · Elsevier eBooks · doi:10.1016/b978-0-323-26278-1.00012-x · Cited by 1
Ali, K. (2017) · International journal of infection control · doi:10.3396/ijic.v13i2.17465 · Cited by 1
Abstracts published at Infection Prevention 2013, London
(2013) · Journal of Infection Prevention · doi:10.1177/1757177413501239 · Cited by 1
Development of novel bioindicators for steam sterilization
Flier, N. (2017) · RWTH Publications (RWTH Aachen) · doi:10.18154/rwth-2017-04261
“Die parentale Anwendung von Arzneimitteln im Körper von Mensch und Tier oder auch die sichere Lagerung von verderblichen biologischen Produkten verlangen die vollständige Entfernung aller vorhandenen Mikroorganismen [10], die sogenannte Sterilität.”
BackgroundMicrobial ecology and antibiotic resistance of microorganisms in intensive care unit environments.
Kay, G. L. (2010) · SHURA (Sheffield Hallam University Research Archive) (Sheffield Hallam University)
Culture of Disinfection: Practical Issues on Decontamination in Healthcare
Kenters, N. (2020) · Radboud Repository (Radboud University)
Development of Biocide Formulations Based on Phytochemical Products for Surface Disinfection
Malheiro, J. (2020) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/nwry-9x55
\(\textit {Bacillus subtilis}\) spore resistance towards low pressure plasma sterilization
Raguse, M. (2017) · Dokumentenrepositorium der RUB (Ruhr University Bochum)
Cambara, J. C. O., Previtali, O., Cuber, P., Lebre, P. H., Ali, S., Chooneea, D., Misra, R., & Mkrtchyan, H. V. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.03.13.711524
Sloan, A., Kasloff, S. B., & Cutts, T. (2022) · doi:10.3389/fmicb.2022.847313.s001
Metadata
- Authors
- Williams, G. J., Denyer, S. P., Hosein, I. K., Hill, D. W., & Maillard, J.-Y.
- Affiliations
- Cardiff University (GB)
- National Health Service (GB)
- Corresponding author
- Williams, Gareth J.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2009-06
- Volume
- 30
- Issue
- 6
- Pages
- 570-573
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2135574859
- Cited by
- 51
- References
- 11
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 5 · 2019: 4 · 2018: 5 · 2017: 2 · 2016: 4 · 2015: 5 · 2014: 4 · 2013: 4 · 2012: 5
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Infection Control and Hospital Epidemiology (publishedVersion)
- PubMed (publishedVersion)
- ORCA Online Research @Cardiff (Cardiff University) (acceptedVersion)
- University of Brighton Repository (University of Brighton) (submittedVersion)
- Funders
- Office of Research and Development
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Keywords
- surface disinfection, methicillin-resistant Staphylococcus aureus, methicillin-susceptible Staphylococcus aureus, bacterial transfer, nosocomial infections, surface contamination
- MeSH terms
- Quaternary Ammonium Compounds, Anti-Bacterial Agents, Biguanides, Cross Infection, Disinfectants, Disinfection, Equipment Contamination, Hospitals, University, Humans, Microbial Sensitivity Tests, Staphylococcal Infections, Staphylococcus aureus, Wales, Infection Control, Methicillin-Resistant Staphylococcus aureus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.