Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review
Open accessAbstract
Ready-to-use disinfecting wipes are increasingly used in hospitals because of convenient implementation and reliable performance, though efficacy depends on multiple variables.
Overview
CoChat Summary
TL;DR
This review summarizes variables affecting disinfectant-impregnated wipe (DIW) efficacy in hospital surface disinfection, emphasizing interactions between wipe materials and active ingredients, especially QAC adsorption onto cotton, as a major cause of disinfection failure. It also critiques current efficacy test standards and concludes that more clinically relevant studies and improved standards are needed.
Key findings
- DIW performance depends on disinfectant type/concentration, wipe material/construction, application method, wiping strategy, storage time, and wipe–disinfectant interaction; the interaction between disinfectant and textile substrate is described as the biggest encumbrance to disinfection performance.
- QACs are the most commonly used disinfectant in wipes, but adsorption onto cotton substrate can reduce active-ingredient concentration and lead to disinfection failure; later work cited in the review found quats adsorption onto cotton can be minimized while maintaining efficacy against *Pseudomonas aeruginosa* and *Staphylococcus aureus*.
- Application methods differ substantially: “Dip and Wipe” uses a 5–10 s dip, “Soak and Wipe” uses 10 min up to 8 h soaking, and ready-to-use disinfecting wipes are pre-wetted with shelf life up to 1 month (can be longer); RTUDW is recommended for compliance, employee time, and costs, but storage may reduce antimicrobial activity and efficacy can decrease on larger wiped surface areas.
- Current standards have key drawbacks: EN 16615 is considered most suitable for DIWs but uses a fixed 16 ml disinfectant volume and PVC/PUR surface with contact time 1–60 min; ASTM E2967–15 uses a Wiperator with 5–45 s contact time on stainless steel; standards generally cannot differentiate mechanical removal of inoculum from chemical inactivation and may yield divergent outcomes.
Methods
- A systematic literature search was conducted via Google Scholar across five categories: wipes, disinfectants, application methods, interaction between wipes and active ingredients, and wiping strategy; clinical efficacy studies were searched from the National Center for Biotechnology Information database.
- Standards and guidelines were reviewed from CEN TC 216, US EPA OPP with AOAC International and ASTM International, ECHA, and CDC/HICPAC.
- Data were extracted by two authors from titles and abstracts obtained from Google Scholar and PubMed; one author checked abstracts against criteria, and full articles deemed necessary were obtained and reviewed by another author.
Limitations
- Stated in the paper: less is known about DIW effectiveness in decontamination; there is no clear understanding of the interaction phenomenon; more studies of DIW disinfection efficacy in clinical practice are needed; and current standards have drawbacks, so one can hardly advocate for DIW use in hospitals.
- Stated in the paper: efficacy standards cannot differentiate mechanical removal from chemical inactivation, need more realistic disinfectant volume per unit surface area, and may produce divergent outcomes; a guideline for comparable results between standards is needed.
- Evident from the text: despite calling the search systematic, the review reports no search strings, date limits, inclusion/exclusion criteria, number of records screened, or quality appraisal, and it provides no quantitative synthesis; the authors also note design limitations in several included studies, such as lack of microbiological tests, use of saline instead of neutralizer, or failure to test wipes in field use.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
15 Valid · 4 Not valid · 35 Not checked · 32 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“In 2007, Williams et al. developed a three-step protocol to quantify the efficacy of disinfectant wipes, their ability to remove and prevent the microbial transfer from surfaces and their overall antimicrobial activity, which could be considered as a milestone for the”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Efficacy studies in literature
What the sources say
- Supportedcites [29] Williams GJ, Denyer SP, Hosein IK, Hill DW, Maillard JY. The development of a new three-step protocol to determine the efficacy of disinfectant wipes on surfaces contaminated with Staphylococcus aureus. J Hosp Infect. 2007;67:329–35. source
The Summary states that the authors developed a three-step protocol to quantify wipe efficacy, removal and prevention of microbial transfer, and overall antimicrobial activity. The Introduction specifies the same three assessments. (LLM, conf=0.95)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“numerous studies showed that the adsorption of QACs onto the cotton substrate wiping material could lead to the failure of the disinfection process [47, 52–58].”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Disinfectant
What the sources say
- Not checked — no full text of the sourcecites [47] Wessels S, Ingmer H. Modes of action of three disinfectant active substances: a review. Regul Toxicol Pharmacol. 2013;67:456–67. source
- Not checked — no full text of the sourcecites [52] Hinchliffe DJ, Condon BD, Slopek RP, Reynolds M. The adsorption of alkyl-dimethyl-benzyl-ammonium chloride onto cotton nonwoven hydroentangled substrates at the solid–liquid interface is minimized by additive chemistries. Text Res J. 2016;87:70–80. source
- Not checked — no full text of the sourcecites [53] Tezel U, Pavlostathis SG. Role of quaternary ammonium compounds on antimicrobial resistance in the environment. Antimicrobial Resistance in the Environment; 2011. p. 349–87. source
- Not checked — no full text of the sourcecites [54] Gerba CP, Müller V. Quaternary ammonium biocides: efficacy in application. Appl Environ Microbiol. 2015;81:464–9. source
- Not checked — no full text of the sourcecites [55] Jennings MC, Minbiole KPC, Wuest WM. Quaternary ammonium compounds: an antimicrobial mainstay and platform for innovation to address bacterial resistance. ACS Infect Dis. 2015;1:288–303. source
- Not checked — no full text of the sourcecites [56] Møretrø T, Heir E, Nesse LL, Vestby LK, Langsrud S. Control of Salmonella in food related environments by chemical disinfection. Food Res Int. 2012;45:532–44. source
- Could not verifycites [57] Ghanbar S, Kazemian MR, Liu S. New generation of N-chloramine/QAC composite biocides: efficient antimicrobial agents to target antibiotic-resistant Bacteria in the presence of organic load. ACS Omega. 2018;3:9699–709. sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports that QACs can bind to proteins in an organic load and lose antimicrobial activity. Our copy does not address adsorption onto cotton wiping material or disinfection failure caused by such adsorption (searched: cotton, wiping material, QAC adsorption). (LLM, conf=0.76)
- Could not verifycites [58] Jiao Y, L-n N, Ma S, Li J, Tay FR, J-h C. Quaternary ammonium-based biomedical materials: state-of-the-art, toxicological aspects and antimicrobial resistance. Prog Polym Sci. 2017;71:53–90. sourceExperimental — accuracy not yet measured
The Sutures and wound dressings section (page unavailable) discusses antibacterial cotton treated with quaternary ammonium compounds, not cotton wipes adsorbing disinfectant. A search for cotton wiping material and QAC adsorption found no passage in our copy linking adsorption onto wipes to disinfection failure. (LLM, conf=0.72)
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“RTUDW is disposable, which eliminates the possible contaminations and transfer of pathogen due to towelettes reuse [64].”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Application method
What the sources say
- Partly supportedcites [64] Tebbutt GM. Laboratory evaluation of disposable and reusable disinfectant cloths for cleaning food contact surfaces. Epidemiol Infect. 2009;101:367–375. sourceExperimental — accuracy not yet measured
The Discussion says disposable wipes would considerably reduce the risk of cross-contamination associated with reusable cloths. It does not say they eliminate that risk, and the paper evaluates disposable alcohol wipes rather than RTUDW specifically. Page numbers were not provided in our copy. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The result implicates a larger wiping surface area may lead to decreased bactericidal efficacy.”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Wiping strategy
What the sources say
- Supportedcites [74] West AM, Nkemngong CA, Voorn MG, Wu T, Li X, Teska PJ, et al. Surface area wiped, product type, and target strain impact bactericidal efficacy of ready-to-use disinfectant Towelettes. Antimicrob Resist Infect Control. 2018;7:1–8. source
The Abstract conclusion states that wiping larger surface areas may decrease bactericidal efficacy. The Discussion likewise reports higher bacterial reductions when wiping one or two square feet than when wiping eight square feet, while noting that the extent of the effect depends on the product. (LLM, conf=0.95)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“the longer storage time could increase the probability of losing antimicrobial activity due to the possible binding of active ingredients onto the towelettes or by the degradation of the active ingredient [73].”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Application method
What the sources say
- Could not verifycites [73] Cadnum JL, Hurless KN, Kundrapu S, Donskey CJ. Transfer of Clostridium difficile spores by nonsporicidal wipes and improperly used hypochlorite wipes practice + product = perfection. Infect Control Hosp Epidemiol. 2015;34:441–2. sourceExperimental — accuracy not yet measured
The methods and findings (pp. 441–442) compare fresh wipes with wipes that dried during use, not wipes kept in storage. The paper does not address longer storage time, binding of active ingredients to towelettes, or ingredient degradation; searches for those terms found no supporting passage. (LLM, conf=0.78)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
30 more claims · 4 with their cited sources checked
Create a free account to see all 86 claims and every source verdict.
- It may state two separate claims as one. 31
- Probably not a substantial claim. 26
Citations
Cites
Estimating Health Care-Associated Infections and Deaths in U.S. Hospitals, 2002
Klevens, R. M., Edwards, J. R., Richards, C. L., Horan, T. C., Gaynes, R. P., Pollock, D. A., & Cardo, D. M. (2007) · Public Health Reports® · doi:10.1177/003335490712200205 · Cited by 2,960
How long do nosocomial pathogens persist on inanimate surfaces? A systematic review
Kramer, A., Schwebke, I., & Kampf, G. (2006) · BMC Infectious Diseases · doi:10.1186/1471-2334-6-130 · Cited by 2,504
Weber, D. J., Rutala, W. A., Miller, M. B., Huslage, K., & Sickbert-Bennett, E. (2010) · American Journal of Infection Control · doi:10.1016/j.ajic.2010.04.196 · Cited by 768 · cited 1×
“shed by patients can 42 contaminate hospital surfaces at concentrations sufficient for transmission, surviving for extended 43 periods and persisting despite attempts to remove them [5-11].”
Dancer, S. J. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-14 · Cited by 679 · cited 5×
“play a key role in preventing cross-contamination [12, 13] and spread 46 of HCAIs [14-19].”
InfluentialThe Role Played by Contaminated Surfaces in the Transmission of Nosocomial Pathogens
Otter, J. A., Yezli, S., & French, G. L. (2011) · Infection Control & Hospital Epidemiology · doi:10.1086/660363 · Cited by 670 · cited 2×
“shed by patients can 42 contaminate hospital surfaces at concentrations sufficient for transmission, surviving for extended 43 periods and persisting despite attempts to remove them [5-11].”
Jennings, M. C., Minbiole, K. P. C., & Wuest, W. M. (2015) · ACS Infectious Diseases · doi:10.1021/acsinfecdis.5b00047 · Cited by 651
Jiao, Y., Niu, L.-N., Ma, S., Li, J., Tay, F. R., & Chen, J.-H. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.03.001 · Cited by 639
Weinstein, R. A., & Hota, B. (2004) · Clinical Infectious Diseases · doi:10.1086/424667 · Cited by 635 · cited 5×
“play a key role in preventing cross-contamination [12, 13] and spread 46 of HCAIs [14-19].”
InfluentialOtter, J. A., Yezli, S., Salkeld, J. A. G., & French, G. L. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2012.12.004 · Cited by 594 · cited 1×
“shed by patients can 42 contaminate hospital surfaces at concentrations sufficient for transmission, surviving for extended 43 periods and persisting despite attempts to remove them [5-11].”
The role of the surface environment in healthcare-associated infections
Weber, D. J., Anderson, D., & Rutala, W. A. (2013) · Current Opinion in Infectious Diseases · doi:10.1097/qco.0b013e3283630f04 · Cited by 567 · cited 1×
“shed by patients can 42 contaminate hospital surfaces at concentrations sufficient for transmission, surviving for extended 43 periods and persisting despite attempts to remove them [5-11].”
Research works printed but not linked: 5
- Amy G, Bull R, Craun GF, Pegram R, Siddiqui M. Organization WH Disinfectants and disinfectant by-products; 2000.
- Edana I. In: Edana I, editor. Guidelines for assessing the Flushability of disposable nonwoven products. Brussels: European Disposables and Nonwovens Association, Association of the Nonwoven Fabrics Industry; 2013.
- Wenger M. Join the A-team: exploring the key role nurses play in antimicrobial stewardship. Can J Crit Care Nurs. 2017;28:50–50.
- Ecolab. Quat Absorption Onto Textiles ECOLAB; 2010. p. 8.
- Agency USEP. Production performance test guidelines OCSPP 8102200: Disinfectants for Use on Hard Surface - Efficacy Data Recommendations: Office of Chemical Safety and Pollution Prevention (7510P), EPA, vol. 29; 2012.
Cited by
Wong, J., Goh, Q. Y., Tan, Z., Lie, S. A., Tay, Y. C., Ng, S. Y., & Soh, C. R. (2020) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-020-01620-9 · Cited by 695
“Quaternary ammonium compounds have good cleaning and deodorization properties with a broad spectrum of biocidal and sporostatic activity, including against lipid-enveloped viruses such as coronaviruses.(69)”
BackgroundHand Sanitizers: A Review on Formulation Aspects, Adverse Effects, and Regulations
Jing, J. L. J., Pei Yi, T., Bose, R. J. C., McCarthy, J. R., Tharmalingam, N., & Madheswaran, T. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17093326 · Cited by 325
Lie, S. A., Wong, S. W., Wong, L. T., Wong, T. G. L., & Chong, S. Y. (2020) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-020-01637-0 · Cited by 185
“The ultrasound machine should be wiped down with quaternary ammonium chloride disinfectant wipes.(40) It should then be left in the OR for ultraviolet C irradiation or hydrogen peroxide vaporization before it is used on another patient.”
MethodChen, B., Han, J., Dai, H., & Jia, P. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.117074 · Cited by 160
A comprehensive review of automatic cleaning systems of solar panels
Derakhshandeh, J. F., AlLuqman, R., Mohammad, S., et al. (2021) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101518 · Cited by 129
Metadata
- Authors
- Song, X., Vossebein, L., & Zille, A.
- Affiliations
- Centro de Ciência e Tecnologia Têxtil (PT)
- Venue
- Antimicrobial Resistance & Infection Control
- Published
- 2019-08-19
- Volume
- 8
- Issue
- 1
- Pages
- 139-139
- ISSN
- 2047-2994 (ISSN-L)
- PMC
- PMC6701098
- OpenAlex
- W2967400753
- Cited by
- 132
- References
- 82
- Citations by year
- 2026: 8 · 2025: 23 · 2024: 15 · 2023: 24 · 2022: 17 · 2021: 29 · 2020: 15 · 2019: 1
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Locations
- Antimicrobial Resistance and Infection Control (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) (submittedVersion, other-oa)
- Funders
- Fundação para a Ciência e a Tecnologia (SFRH/BD/130028/2017, IF/00071/2015, UID/CTM/00264/2019)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- surface disinfection, hospital infection control, disinfectant efficacy, medical device decontamination
- MeSH terms
- Cross Infection, Disinfectants, Disinfection, Environmental Microbiology, Equipment Contamination, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review. https://app.cochat.ai/papers/10.1186/s13756-019-0595-2
- The paper
- Song, X., Vossebein, L., & Zille, A. (2019). Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review. Antimicrobial Resistance & Infection Control. https://doi.org/10.1186/s13756-019-0595-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.