Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review

Open access
Song, Xinyu, Vossebein, Lutz, Zille, Andrea · 2019 · Antimicrobial Resistance & Infection Control

Abstract

Ready-to-use disinfecting wipes are increasingly used in hospitals because of convenient implementation and reliable performance, though efficacy depends on multiple variables.

Overview

CoChat Summary

TL;DR

This review summarizes variables affecting disinfectant-impregnated wipe (DIW) efficacy in hospital surface disinfection, emphasizing interactions between wipe materials and active ingredients, especially QAC adsorption onto cotton, as a major cause of disinfection failure. It also critiques current efficacy test standards and concludes that more clinically relevant studies and improved standards are needed.

Key findings

  • DIW performance depends on disinfectant type/concentration, wipe material/construction, application method, wiping strategy, storage time, and wipe–disinfectant interaction; the interaction between disinfectant and textile substrate is described as the biggest encumbrance to disinfection performance.
  • QACs are the most commonly used disinfectant in wipes, but adsorption onto cotton substrate can reduce active-ingredient concentration and lead to disinfection failure; later work cited in the review found quats adsorption onto cotton can be minimized while maintaining efficacy against *Pseudomonas aeruginosa* and *Staphylococcus aureus*.
  • Application methods differ substantially: “Dip and Wipe” uses a 5–10 s dip, “Soak and Wipe” uses 10 min up to 8 h soaking, and ready-to-use disinfecting wipes are pre-wetted with shelf life up to 1 month (can be longer); RTUDW is recommended for compliance, employee time, and costs, but storage may reduce antimicrobial activity and efficacy can decrease on larger wiped surface areas.
  • Current standards have key drawbacks: EN 16615 is considered most suitable for DIWs but uses a fixed 16 ml disinfectant volume and PVC/PUR surface with contact time 1–60 min; ASTM E2967–15 uses a Wiperator with 5–45 s contact time on stainless steel; standards generally cannot differentiate mechanical removal of inoculum from chemical inactivation and may yield divergent outcomes.

Methods

  • A systematic literature search was conducted via Google Scholar across five categories: wipes, disinfectants, application methods, interaction between wipes and active ingredients, and wiping strategy; clinical efficacy studies were searched from the National Center for Biotechnology Information database.
  • Standards and guidelines were reviewed from CEN TC 216, US EPA OPP with AOAC International and ASTM International, ECHA, and CDC/HICPAC.
  • Data were extracted by two authors from titles and abstracts obtained from Google Scholar and PubMed; one author checked abstracts against criteria, and full articles deemed necessary were obtained and reviewed by another author.

Limitations

  • Stated in the paper: less is known about DIW effectiveness in decontamination; there is no clear understanding of the interaction phenomenon; more studies of DIW disinfection efficacy in clinical practice are needed; and current standards have drawbacks, so one can hardly advocate for DIW use in hospitals.
  • Stated in the paper: efficacy standards cannot differentiate mechanical removal from chemical inactivation, need more realistic disinfectant volume per unit surface area, and may produce divergent outcomes; a guideline for comparable results between standards is needed.
  • Evident from the text: despite calling the search systematic, the review reports no search strings, date limits, inclusion/exclusion criteria, number of records screened, or quality appraisal, and it provides no quantitative synthesis; the authors also note design limitations in several included studies, such as lack of microbiological tests, use of saline instead of neutralizer, or failure to test wipes in field use.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s13756-019-0595-2

Cites

82 of 82 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

15 Valid · 4 Not valid · 35 Not checked · 32 Own results and interpretations

30 more claims · 4 with their cited sources checked

Create a free account to see all 86 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 31
  • Probably not a substantial claim. 26

Create a free account to see these claims.

Citations

Cites

Show all 82 references

Research works printed but not linked: 5

  1. Amy G, Bull R, Craun GF, Pegram R, Siddiqui M. Organization WH Disinfectants and disinfectant by-products; 2000.
  2. Edana I. In: Edana I, editor. Guidelines for assessing the Flushability of disposable nonwoven products. Brussels: European Disposables and Nonwovens Association, Association of the Nonwoven Fabrics Industry; 2013.
  3. Wenger M. Join the A-team: exploring the key role nurses play in antimicrobial stewardship. Can J Crit Care Nurs. 2017;28:50–50.
  4. Ecolab. Quat Absorption Onto Textiles ECOLAB; 2010. p. 8.
  5. Agency USEP. Production performance test guidelines OCSPP 8102200: Disinfectants for Use on Hard Surface - Efficacy Data Recommendations: Office of Chemical Safety and Pollution Prevention (7510P), EPA, vol. 29; 2012.

Cited by

See all 132

Metadata

Authors
Song, X., Vossebein, L., & Zille, A.
Affiliations
Centro de Ciência e Tecnologia Têxtil (PT)
Venue
Antimicrobial Resistance & Infection Control
Published
2019-08-19
Volume
8
Issue
1
Pages
139-139
ISSN
2047-2994 (ISSN-L)
OpenAlex
W2967400753
Cited by
132
References
82
Citations by year
2026: 8 · 2025: 23 · 2024: 15 · 2023: 24 · 2022: 17 · 2021: 29 · 2020: 15 · 2019: 1
FWCI
2.16
Type
journal article
Language
en
Open access
Licence
Locations
  • Antimicrobial Resistance and Infection Control (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) (submittedVersion, other-oa)
Funders
Fundação para a Ciência e a Tecnologia (SFRH/BD/130028/2017, IF/00071/2015, UID/CTM/00264/2019)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
  • Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
Keywords
surface disinfection, hospital infection control, disinfectant efficacy, medical device decontamination
MeSH terms
Cross Infection, Disinfectants, Disinfection, Environmental Microbiology, Equipment Contamination, Humans

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review. https://app.cochat.ai/papers/10.1186/s13756-019-0595-2
The paper
Song, X., Vossebein, L., & Zille, A. (2019). Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review. Antimicrobial Resistance & Infection Control. https://doi.org/10.1186/s13756-019-0595-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.