Ongoing Revolution in Bacteriology: Routine Identification of Bacteria by Matrix‐Assisted Laser Desorption Ionization Time‐of‐Flight Mass Spectrometry
The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry accurately identifies both selected bacteria and bacteria in select clinical situations. It has not been evaluated for routine use in the clinic. METHODS: We prospectively analyzed routine MALDI-TOF mass spectrometry identification in parallel with conventional phenotypic identification of bacteria regardless of phylum or source of isolation. Discrepancies were resolved by 16S ribosomal RNA and rpoB gene sequence-based molecular identification. Colonies (4 spots per isolate directly deposited on the MALDI-TOF plate) were analyzed using an Autoflex II Bruker Daltonik mass spectrometer. Peptidic spectra were compared with the Bruker BioTyper database, version 2.0, and the identification score was noted. Delays and costs of identification were measured. RESULTS: Of 1660 bacterial isolates analyzed, 95.4% were correctly identified by MALDI-TOF mass spectrometry; 84.1% were identified at the species level, and 11.3% were identified at the genus level. In most cases, absence of identification (2.8% of isolates) and erroneous identification (1.7% of isolates) were due to improper database entries. Accurate MALDI-TOF mass spectrometry identification was significantly correlated with having 10 reference spectra in the database (P=.01). The mean time required for MALDI-TOF mass spectrometry identification of 1 isolate was 6 minutes for an estimated 22%-32% cost of current methods of identification. CONCLUSIONS: MALDI-TOF mass spectrometry is a cost-effective, accurate method for routine identification of bacterial isolates in <1 h using a database comprising > or =10 reference spectra per bacterial species and a 1.9 identification score (Brucker system). It may replace Gram staining and biochemical identification in the near future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“MALDI–time-of-flight (TOF)–MS, once considered revolutionary, is now established as a routine tool in clinical microbiology133.”
From A high-stringency blueprint of the human proteome (2020) · cites this paper as [133]
Citations
Cites
Manual of Clinical Microbiology.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-6-939_2 · Cited by 14,411
Taxonomic parameters revisited : tarnished gold standards
Stackebrandt, E. S. (2006) · Medical Entomology and Zoology · Cited by 1,895
Phylogenetic affiliation of the pseudomonads based on 16S rRNA sequence.
Anzai, Y., Kim, H., Park, J. Y., Wakabayashi, H., & Oyaizu, H. (2000) · International Journal of Systematic and Evolutionary Microbiology · doi:10.1099/00207713-50-4-1563 · Cited by 881
The rapid identification of intact microorganisms using mass spectrometry
Claydon, M. A., Davey, S. N., Edwards-Jones, V., & Gordon, D. B. (1996) · Nature Biotechnology · doi:10.1038/nbt1196-1584 · Cited by 609
Identification of bacteria using mass spectrometry
Anhalt, J. P., & Fenselau, C. (1975) · Analytical Chemistry · doi:10.1021/ac60352a007 · Cited by 504
KAWAMURA, Y., HOU, X.-G., SULTANA, F., MIURA, H., & EZAKI, T. (1995) · International Journal of Systematic Bacteriology · doi:10.1099/00207713-45-2-406 · Cited by 503
Mellmann, A., Cloud, J., Maier, T., Keckevoet, U., Ramminger, I., Iwen, P., Dunn, J., Hall, G., Wilson, D., LaSala, P., et al. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.00157-08 · Cited by 435
The rpoB gene as a tool for clinical microbiologists
Adékambi, T., Drancourt, M., & Raoult, D. (2009) · Trends in Microbiology · doi:10.1016/j.tim.2008.09.008 · Cited by 355
Self-citationClassification and Identification of Bacteria by Mass Spectrometry and Computational Analysis
Sauer, S., Freiwald, A., Maier, T., Kube, M., Reinhardt, R., Kostrzewa, M., & Geider, K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002843 · Cited by 335
Microorganism Identification by Mass Spectrometry and Protein Database Searches
Demirev, P. A., Ho, Y.-P., Ryzhov, V., & Fenselau, C. (1999) · Analytical Chemistry · doi:10.1021/ac990165u · Cited by 326
Cited by
Items 601–700 of 1,000
Fibrinogen alpha chain O-glycopeptides as possible markers of urinary tract infection
Pacchiarotta, T., Hensbergen, P. J., Wuhrer, M., van Nieuwkoop, C., Nevedomskaya, E., Derks, R. J. E., Schoenmaker, B., Koeleman, C. A. M., van Dissel, J., Deelder, A. M., et al. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.10.021 · Cited by 32
Kok, J., Chen, S. C.-A., Dwyer, D. E., & Iredell, J. R. (2012) · Pathology · doi:10.1097/pat.0b013e32835be408 · Cited by 32
“identification from 5–48 hours to 6 minutes.(30) Gaillot et al.”
BackgroundForlani, A., Palmieri, C., Santagostino, S. F., Queliti, R., & Roccabianca, P. (2016) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.248.6.621 · Cited by 33
Togo, A. H., Khelaifia, S., Bittar, F., Maraninchi, M., Raoult, D., & Million, M. (2016) · New Microbes and New Infections · doi:10.1016/j.nmni.2016.05.015 · Cited by 32
“spectrum could not be identified by our systematic matrixassisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF-MS) screening on a Microflex spectrometer (Bruker Daltonics, Bremen, Germany) was identified by the 16S rRNA gene sequencing [4].”
Self-citationPham, T.-P.-T., Cadoret, F., Alou, M. T., Brah, S., Diallo, B. A., Diallo, A., Sokhna, C., Delerce, J., Fournier, P., Million, M., et al. (2017) · New Microbes and New Infections · doi:10.1016/j.nmni.2017.02.004 · Cited by 32
“E-mail: matthieumillion@gmail.com In 2016, as a part of culturomics study of the human microbiome, we isolated five bacterial strains from stool samples of patients in Senegal and Niger with malnutrition (marasmus and kwashiorkor) [6,7] that could not be identified by our systematic matrix-assisted laser desorption– i…”
BackgroundSelf-citationRapid typing of Mannheimia haemolytica major genotypes 1 and 2 using MALDI-TOF mass spectrometry
Loy, J. D., & Clawson, M. L. (2017) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2017.03.002 · Cited by 32
Many More Microbes in Humans: Enlarging the Microbiome Repertoire
Lagier, J., Drancourt, M., Charrel, R. N., Bittar, F., Scola, B. L., Ranque, S., & Raoult, D. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/cix404 · Cited by 32
Self-citationElbehiry, A., Aldubaib, M., Rugaie, O. A., Marzouk, E., Abaalkhail, M., Moussa, I. M., El-Husseiny, M. H., Abalkhail, A., & Rawway, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262551 · Cited by 32
“Through the properties of a spectra database kept in the library of MBT device, the associated software scans for matching with the microbial species, based on a consistent list between both spectra [30, 31].”
MethodLoucif, L., Chelaghma, W., Cherak, Z., Bendjama, E., Beroual, F., & Rolain, J. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.152861 · Cited by 36
Self-citationSchumaker, S., Borror, C. M., & Sandrin, T. R. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5309 · Cited by 32
Nonculture‐based identification of bacteria in milk by protein fingerprinting
Barreiro, J. R., Braga, P. A. D. C., Ferreira, C. R., Kostrzewa, M., Maier, T. H. P., Wegemann, B., Böettcher, V., Eberlin, M. N., & dos Santos, M. V. (2012) · PROTEOMICS · doi:10.1002/pmic.201200053 · Cited by 32
Enterococcus cecorum human infection, France
Delaunay, É., Abat, C., & Rolain, J. (2015) · New Microbes and New Infections · doi:10.1016/j.nmni.2015.06.004 · Cited by 32
Self-citationA simple shotgun proteomics method for rapid bacterial identification
Tracz, D. M., McCorrister, S. J., Chong, P. M., Lee, D. M., Corbett, C. R., & Westmacott, G. (2013) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2013.04.008 · Cited by 32
Unravelling diversity of deep-sea copepods using integrated morphological and molecular techniques
Bode, M., Laakmann, S., Kaiser, P., Hagen, W., Auel, H., & Cornils, A. (2017) · Journal of Plankton Research · doi:10.1093/plankt/fbx031 · Cited by 32
Nabti, L. Z., Sahli, F., Radji, N., Mezaghcha, W., Semara, L., Aberkane, S., Lounnas, M., Solassol, J., Didelot, M.-N., Jean‐Pierre, H., et al. (2019) · Microbial Drug Resistance · doi:10.1089/mdr.2018.0314 · Cited by 38
Mishra, A. K., Lagier, J., Robert, C., Raoult, D., & Fournier, P. (2013) · Standards in Genomic Sciences · doi:10.4056/sigs.3476977 · Cited by 31
“Matrix-assisted laser-desorption/ionization timeof-flight (MALDI-TOF) MS protein analysis was carried out as previously described [34].”
MethodSelf-citationNon-contiguous finished genome sequence and description of Megasphaera massiliensis sp. nov.
Padmanabhan, R., Lagier, J., Nieko, N. P. M. D., Michelle, C., Couderc, C., Raoult, D., & Fournier, P. (2013) · Standards in Genomic Sciences · doi:10.4056/sigs.4077819 · Cited by 31
Self-citationPrinciples and Mechanism of MALDI-ToF-MS Analysis
Hosseini, S., & Martinez-Chapa, S. O. (2016) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-981-10-2356-9_1 · Cited by 37
Teng, J. L. L., Tang, Y., Wong, S. S. Y., Fong, J. Y. H., Zhao, Z., Wong, C.-P., Chen, J. H.-K., Ngan, A. H. Y., Wu, A. K. L., Fung, K. S. C., et al. (2018) · Emerging Microbes & Infections · doi:10.1038/s41426-018-0083-4 · Cited by 31
Fong, P., Francis, M. J., Hamblin, J. F., Korman, T. M., & Graham, M. (2018) · Anaerobe · doi:10.1016/j.anaerobe.2018.09.007 · Cited by 31
Wilson, D. J., Middleton, J. R., Adkins, P. R. F., & Goodell, G. M. (2018) · Journal of Clinical Microbiology · doi:10.1128/jcm.01381-18 · Cited by 31
“0 for genus and species level was applied, using an algorithm for duplicate testing of the same colony (10).”
BackgroundMethodResultShelf life extension of sugarcane juice by cross flow hollow fibre ultrafiltration
Panigrahi, C., Mondal, M., Karmakar, S., Mishra, H. N., & De, S. (2019) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2019.109880 · Cited by 31
Non contiguous-finished genome sequence and description of Peptoniphilus grossensis sp. nov.
Mishra, A. K., Hugon, P., Robert, C., Raoult, D., & Fournier, P. (2012) · Standards in Genomic Sciences · doi:10.4056/sigs.3076460 · Cited by 43
“324 Standards in Genomic Sciences Matrix-assisted laser-desorption/ionization time-of-flight (MALDI-TOF) MS protein analysis was carried out as previously described [20].”
MethodSelf-citationBacteroides , Porphyromonas , Prevotella , Fusobacterium , and Other Anaerobic Gram-Negative Rods
Könönen, E., Conrads, G., & Nagy, E. (2015) · ASM Press eBooks · doi:10.1128/9781555817381.ch54 · Cited by 38
Foodomics to investigate meat tenderness
D’Alessandro, A., & Zolla, L. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.05.017 · Cited by 31
“MS-based approaches now allow reliable screening and identification of plated microorganisms in the light of the introduction of MALDI-based microbial screening strategies [56].”
Calderaro, A., Piccolo, G., Gorrini, C., Montecchini, S., Buttrini, M., Rossi, S., Piergianni, M., Conto, F. D., Arcangeletti, C., Chezzi, C., et al. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-330 · Cited by 31
“Matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) emerged over the last years as a first line technique for the rapid bacterial identification [20,21].”
MethodMestas, J., Felsenstein, S., & Bard, J. D. (2014) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2014.07.008 · Cited by 31
EXPRESSION OF CONCERN: Microvirga massiliensis sp. nov., the human commensal with the largest genome
Caputo, A., Lagier, J., Azza, S., Robert, C., Mouelhi, D., Fournier, P., & Raoult, D. (2016) · MicrobiologyOpen · doi:10.1002/mbo3.329 · Cited by 31
“Recently, by adapting MALDI- TOF to the routine identification of bacterial species, clinical isolated identification was made possible for the first time (La Scola and Raoult 2009; Seng et al. 2009, 2013).”
MethodSelf-citationNon contiguous-finished genome sequence and description of Microbacterium gorillae sp. nov.
Hadjadj, L., Rathored, J., Keita, M. B., Michelle, C., Levasseur, A., Raoult, D., Fournier, P., Rolain, J., & Bittar, F. (2016) · Standards in Genomic Sciences · doi:10.1186/s40793-016-0152-z · Cited by 31
“Matrix-assisted laser-desorption/ionization time-of-flight (MALDI-TOF) MS protein analysis was carried out as previously described [17] using a Microflex spectrometer (Bruker Daltonics, Leipzig, Germany).”
MethodSelf-citationColistin- and Carbapenem-Resistant Klebsiella pneumoniae Clinical_Isolates: Algeria
Yousfi, H., Hadjadj, L., Dandachi, I., Lalaoui, R., Merah, A., Amoura, K., Dahi, A., Dekhil, M., Messalhi, N., Diene, S. M., et al. (2018) · Microbial Drug Resistance · doi:10.1089/mdr.2018.0147 · Cited by 31
Self-citationAn ensemble approach to the structure-function problem in microbial communities
Gopalakrishnappa, C., Gowda, K., Prabhakara, K., & Kuehn, S. (2022) · iScience · doi:10.1016/j.isci.2022.103761 · Cited by 35
“By performing MALDI-TOF (see below) mass spectrometry directly on colonies, bacterial taxa can be identified with high fidelity (Seng et al., 2009).”
BackgroundMethodAbdulWahab, A., Taj‐Aldeen, S. J., Ibrahim, E. B., Talaq, E., Abu-Madi, M. A., & Fotedar, R. (2015) · Infection and Drug Resistance · doi:10.2147/idr.s80341 · Cited by 30
“Matrix-assisted laser desorption/ ionization-time of flight mass spectrometry (MALDI-TOF MS) has been recently introduced in clinical microbiology laboratories as a newly emerging technology applied to the problem of bacterial species identification.(10) Several studies have reported the use of MALDI-TOF MS for identi…”
MethodNon-contiguous finished genome sequence and description of Bartonella senegalensis sp. nov.
Mediannikov, O., Karkouri, K. E., Diatta, G., Robert, C., Fournier, P., & Raoult, D. (2013) · Standards in Genomic Sciences · doi:10.4056/sigs.3807472 · Cited by 30
“Matrix-assisted laser desorption/ionization timeof-flight (MALDI-TOF) mass spectrometry protein analysis was carried out as previously described [33].”
MethodSelf-citationPathogen identification using mass spectrometry in the clinical microbiology laboratory
Drake, R. R., Boggs, S. R., & Drake, S. K. (2011) · Journal of Mass Spectrometry · doi:10.1002/jms.2008 · Cited by 33
Bataineh, M. T. A., Sutton, D. A., Fothergill, A. W., & Wiederhold, N. P. (2015) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2015.10.014 · Cited by 30
Benslama, O., & Boulahrouf, A. (2016) · Genomics Data · doi:10.1016/j.gdata.2016.03.005 · Cited by 30
“The matrix-assisted laser-desorption/ionization time-of-flight mass spectrometer analysis (MALDI-TOF-MS) (Bruker Daltonics, Bremen, Germany) was carried-out as previously described [27].”
MethodBaron, S. A., Leulmi, Z., Villard, C., Olaitan, A. O., Telke, A. A., & Rolain, J. (2017) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2017.11.017 · Cited by 31
“Identification of the strains 103 was done by MALDI-TOF (Matrix-Assisted Laser Desorption Ionization-Time of Flight) (23) 104 and confirmed by both 16S ribosomal RNA (rRNA) gene and rpoB gene sequence analysis.”
MethodSelf-citationMatrix-Assisted Laser Desorption Time of Flight Mass Spectrometry
Wolk, D. M., & Clark, A. E. (2018) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2018.05.008 · Cited by 30
Mörtelmaier, C., Panda, S., Robertson, I., Krell, M., Christodoulou, M., Reichardt, N., & Mulder, I. E. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02080-x · Cited by 38
“The use of matrix-assisted laser desorption ionization-time-offlight mass spectrometry (MALDI-ToF-MS) has made the identification of microorganisms quick, reliable, and costeffective and hence allowed high-throughput identification (so called “biotyping”) [1].”
MethodChelaghma, W., Loucif, L., Bendjama, E., Cherak, Z., Bendahou, M., & Rolain, J. (2022) · Antibiotics · doi:10.3390/antibiotics11080988 · Cited by 40
Self-citationPiksa, M., Fortuna, W., Lian, C., Gacka, M., Samuel, I. D. W., Matczyszyn, K., & Pawlik, K. (2023) · Scientific Reports · doi:10.1038/s41598-023-39363-4 · Cited by 44
MALDI-TOF Mass Spectrometry for Microorganism Identification
Bourassa, L. A., & Butler‐Wu, S. M. (2015) · Methods in microbiology · doi:10.1016/bs.mim.2015.07.003 · Cited by 42
Identification of Rare Bacterial Pathogens by 16S rRNA Gene Sequencing and MALDI-TOF MS
Schröttner, P., Gunzer, F., Schüppel, J., & Rudolph, W. W. (2016) · Journal of Visualized Experiments · doi:10.3791/53176 · Cited by 30
Detection of microbial DNAemia: does it matter for sepsis management?
Struelens, M. J. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1710-2 · Cited by 30
“using mass-spectrometry [6].”
Intelicato-Young, J., & Fox, A. (2013) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2013.01.004 · Cited by 29
“It has also been estimated that use of direct MALDI-TOF MS could be 22−32% of the cost of the current methods routinely employed (Seng et al., 2009).”
MethodArinto-Garcia, R., Pinho, M. D., Carriço, J. A., Melo‐Cristino, J., & Ramirez, M. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.01892-15 · Cited by 29
“It has been suggested that to allow reliable identifications, each species should be represented by 10 or more strains in order to cover the naturally occurring diversity (26, 28, 41).”
BackgroundMethodElsawi, Z., Togo, A. H., Beye, M., Dubourg, G., Andrieu, C., Armsrtong, N., Richez, M., Pinto, F. D., Bittar, F., Labas, N., et al. (2017) · MicrobiologyOpen · doi:10.1002/mbo3.458 · Cited by 29
“Measurements and proteomic analysis of the isolate were carried out with a Microflex spectrometer (Bruker) as previously described (Seng et al., 2009).”
MethodSelf-citationNebbak, A., Willcox, A. C., Koumare, S., Bérenger, J.-M., Raoult, D., Parola, P., Fontaine, A., Briolant, S., & Alméras, L. (2018) · Pest Management Science · doi:10.1002/ps.5196 · Cited by 28
Self-citationNosocomial Pneumonia in the Era of Multidrug-Resistance: Updates in Diagnosis and Management
Xu, E., Pérez-Torres, D., Fragkou, P. C., Zahar, J., & Koulenti, D. (2021) · Microorganisms · doi:10.3390/microorganisms9030534 · Cited by 34
“It requires only six minutes to identify each isolate, but of note, it can only use isolates from cultures; despite the initial cost to acquire the equipment, it has been reported to be cost-effective [61,62].”
BackgroundDifferentiation of Gastric Helicobacter Species Using MALDI-TOF Mass Spectrometry
Berlamont, H., Witte, C. D., Bruyckere, S. D., Fox, J. G., Backert, S., Smet, A., Boyen, F., & Haesebrouck, F. (2021) · Pathogens · doi:10.3390/pathogens10030366 · Cited by 32
“While MALDI-TOF MS is considered a rapid and accurate tool for microbial identification, certain drawbacks must be considered [28,34].”
BackgroundIdelevich, E. A., & Becker, K. (2021) · Journal of Clinical Microbiology · doi:10.1128/jcm.01814-19 · Cited by 29
“It has been praised as revolution or paradigm shift (2, 3),”
BackgroundHonsig, C., Selitsch, B., Hollenstein, M., Vossen, M. G., Spettel, K., & Willinger, B. (2022) · Journal of Fungi · doi:10.3390/jof8040383 · Cited by 30
Use of MALDI-TOF mass spectrometry for virus identification: a review
Do, T., Guráň, R., Adam, V., & Zítka, O. (2022) · The Analyst · doi:10.1039/d2an00431c · Cited by 30
Molecular diagnosis in HAP/VAP
Lung, M., & Codina, M. G. (2012) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3283577d37 · Cited by 34
Callaway, A., Kostrzewa, M., Willershausen, B., Schmidt, F., Thiede, B., Küpper, H., & Kneist, S. (2013) · Clinical Laboratory · doi:10.7754/clin.lab.2013.121225 · Cited by 36
Kailasa, S. K., Koduru, J. R., Park, T. J., Wu, H., & Lin, Y. (2019) · The Analyst · doi:10.1039/c8an02034e · Cited by 29
Anani, H., Abdallah, R. A., Chelkha, N., Fontanini, A., Ricaboni, D., Mailhé, M., Raoult, D., & Fournier, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-44343-8 · Cited by 30
Self-citationTobacco Smoking Affects the Salivary Gram-Positive Bacterial Population
Grine, G., Royer, A., Terrer, E., Diallo, O. O., Drancourt, M., & Aboudharam, G. (2019) · Frontiers in Public Health · doi:10.3389/fpubh.2019.00196 · Cited by 29
Self-citationRetractedPage, S. L., van Belkum, A., Fulchiron, C., Huguet, R., Raoult, D., & Rolain, J. (2015) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-015-2424-8 · Cited by 33
“After identification by MALDI-TOF mass spectrometry, AST was performed on solid medium according to the DD method [3].”
MethodSelf-citationAcceptance criteria for identification results of Gram-negative rods by mass spectrometry
Bel, A. D., Wybo, I., Vandoorslaer, K., Rosseel, P., Lauwers, S., & Piérard, D. (2011) · Journal of Medical Microbiology · doi:10.1099/jmm.0.023184-0 · Cited by 28
Reich, M. (2013) · Journal of Bacteriology & Parasitology · doi:10.4172/2155-9597.s5-002 · Cited by 30
“This conformity is in the range as observed by others [20,21].”
ResultMathlouthi, N., Lamine, Y. B., Somai, R., Bouhalila-Besbes, S., Bakour, S., Rolain, J., & Chouchani, C. (2017) · Microbial Drug Resistance · doi:10.1089/mdr.2016.0306 · Cited by 28
Self-citationBacterial Whole Cell Typing by Mass Spectra Pattern Matching with Bootstrapping Assessment
Yang, Y., Lin, Y., Chen, Z., Gong, T., Yang, P., Girault, H. H., Liu, B., & Qiao, L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03820 · Cited by 28
Pinault, L., Chabrière, É., Raoult, D., & Fenollar, F. (2019) · Journal of Clinical Microbiology · doi:10.1128/jcm.01678-18 · Cited by 28
Self-citationMALDI-MS for polymer characterization – Recent developments and future prospects
Drzeżdżon, J., Jacewicz, D., Sielicka, A., & Chmurzyński, L. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.04.004 · Cited by 28
Liao, X., Yang, R., Xia, J., Chen, L., Zhang, R., Fang, L., Lei, F., Song, G., Jia, L., Han, L., et al. (2019) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkz268 · Cited by 34
Deblais, L., Kathayat, D., Helmy, Y. A., Closs, G., & Rajashekara, G. (2020) · Animal Health Research Reviews · doi:10.1017/s1466252319000124 · Cited by 33
Doellinger, J., Schneider, A., Stark, T. D., Ehling‐Schulz, M., & Lasch, P. (2020) · Frontiers in Microbiology · doi:10.3389/fmicb.2020.511674 · Cited by 28
“Within the last decade MALDI-ToF MS has revolutionized the way pathogens are identified (Seng et al., 2009; Nomura, 2015; Schubert and Kostrzewa, 2017; Welker et al., 2019).”
BackgroundHong, N., Chen, M., & Xu, J. (2021) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2021.683670 · Cited by 35
“MALDI-TOF MS has become a rapid, easy-to-use, and inexpensive method for identifying clinically important microorganisms (Claydon et al., 1996; Krishnamurthy and Ross, 1996; Seng et al., 2009).”
MethodSchmitt, F., Clermidi, P., Dorsi, M., Cocquerelle, V., Gomes, C. F., & Becmeur, F. (2012) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2012.04.025 · Cited by 28
Rapid identification of Streptomyces isolates by MALDI-TOF MS
Loucif, L., Bendjama, E., Gacemi-Kirane, D., & Rolain, J. (2014) · Microbiological Research · doi:10.1016/j.micres.2014.04.004 · Cited by 28
Self-citationNie, S., Tian, B., Wang, X., Pincus, D., Welker, M., Gilhuley, K. A., Lu, X., Han, Y. W., & Tang, Y. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.00239-15 · Cited by 28
“Until now, MALDI-TOF MS has had difficulty identifying organisms in the genus Fusobacterium to the species level (14), albeit their medical relevance is increasingly recognized (15).”
BackgroundHertel, M., Hartwig, S., Schütte, E., Gillissen, B. F., Preißner, R., Schmidt‐Westhausen, A. M., Paris, S., Kastner, I., & Preißner, S. (2015) · Mycoses · doi:10.1111/myc.12442 · Cited by 28
Cimmino, T. P., & Rolain, J. (2016) · New Microbes and New Infections · doi:10.1016/j.nmni.2016.03.006 · Cited by 30
“Presumptive identification was done by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS; Microflex, Bruker Daltonics, Leipzig, Germany) using the flex control software (Bruker Daltonics) as previously described [19].”
MethodSelf-citationRETRACTED ARTICLE: Molecular strategy for the diagnosis of infectious lymphadenitis
Prudent, E., Scola, B. L., Drancourt, M., Angelakis, E., & Raoult, D. (2018) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-018-3238-2 · Cited by 29
Self-citationRetractedOptimization of mass spectral features in MALDI-TOF MS profiling of Acinetobacter species
Šedo, O., Voráč, A., & Zdráhal, Z. (2011) · Systematic and Applied Microbiology · doi:10.1016/j.syapm.2010.11.008 · Cited by 27
Tudó, G., Monté, M. R., Vergara, A., López, A., Hurtado, J. C., Ferrer‐Navarro, M., Vilà, J., & Gonzalez-Martin, J. (2015) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-015-2381-2 · Cited by 27
“The matrixassisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) technique provides a rapid alternative for the identification of microorganisms based on differences in their protein profile [6–8].”
MethodXiao, D., Zhao, F., Lv, M., Zhang, H., Zhang, Y., Huang, H., Su, P., Zhang, Z., & Zhang, J. (2012) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2012.04.004 · Cited by 27
“…pathogens, including Gram-positive and Gram-negative bacteria, yeast, and fungus (Camara and Hays, 2007; Carbonnelle et al., 2007; Degrand et al., 2008; Rajakaruna et al., 2009; Seng et al., 2009; Stevenson et al., 2010; Szabados et al., 2010; Szabados et al., 2011; Van Veen et al., 2010).”
BackgroundMethodInfluentialKurokawa, S., Kabayama, J., Fukuyasu, T., Hwang, S. D., Park, C., Park, S.-B., del Castillo, C. S., Hikima, J.-I., Jung, T. S., Kondo, H., et al. (2012) · Marine Biotechnology · doi:10.1007/s10126-012-9492-x · Cited by 27
“2010), especially with the demonstrated ability to differentiate to the species level in several genera (Bessede et al. 2011; Cherkaoui et al. 2010; Eigner et al. 2009; La Scola and Raoult 2009; Sauer and Kliem 2010; Seng et al. 2009; van Veen et al. 2010).”
BackgroundMethodInfluentialPaz, B., Riobó, P., & Franco, J. M. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5264 · Cited by 27
Noncontiguous finished genome sequence and description of Paenibacillus ihumii sp. nov. strain AT5
Togo, A. H., Khelaifia, S., Lagier, J., Caputo, A., Robert, C., Fournier, P., Maraninchi, M., Valéro, R., Raoult, D., & Million, M. (2016) · New Microbes and New Infections · doi:10.1016/j.nmni.2016.01.013 · Cited by 28
“They were then identified by MALDI-TOF as described elsewhere [9].”
MethodSelf-citationLellman, S. E., & Cramer, R. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0908 · Cited by 29
Multidrug-Resistant Klebsiella pneumoniae Clones from Wild Chimpanzees and Termites in Senegal
Baron, S. A., Mediannikov, O., Abdallah, R., Yimagou, E. K., Medkour, H., Dubourg, G., Elamire, Y., Afouda, P., Ngom, I. I., Angelakis, E., et al. (2021) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.02557-20 · Cited by 35
“Identification of strains was performed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF) as previously described (31).”
MethodSelf-citationTogo, A. H., Valéro, R., Delerce, J., Raoult, D., & Million, M. (2016) · New Microbes and New Infections · doi:10.1016/j.nmni.2016.07.015 · Cited by 27
“The strain AT3 is a bacterial strain, whose spectrum could not be identified bymatrixassisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) screening on a Microflex spectrometer (Bruker Daltonics, Germany) [2].”
BackgroundSelf-citationHe, Y., Chang, T. C., Li, H., Shi, G., & Tang, Y. (2011) · Canadian Journal of Microbiology · doi:10.1139/w11-039 · Cited by 27
Croxatto, A., Prod’hom, G., Durussel, C., & Greub, G. (2014) · Journal of Visualized Experiments · doi:10.3791/51985 · Cited by 29
Diene, S. M., L’homme, T., Bellulo, S., Stremler, N., Dubus, J. ‐., Mély, L., Leroy, S., Degand, N., & Rolain, J. (2013) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2013.06.001 · Cited by 27
Self-citationRichter, C., Hollstein, S., Woloszyn, J., Kaase, M., Gatermann, S. G., & Szabados, F. (2012) · Journal of Medical Microbiology · doi:10.1099/jmm.0.042606-0 · Cited by 27
“MALDI-TOF MS has been shown to be accurate in both sensitivity and specificity at the species level for staphylococci (Seng et al., 2009; Dupont et al., 2010; Szabados et al., 2012).”
BackgroundMethodInfluentialUdder health in beef cows and its association with calf growth
Waller, K. P., Persson, Y., Nyman, A.-K., & Stengärde, L. (2014) · Acta veterinaria Scandinavica · doi:10.1186/1751-0147-56-9 · Cited by 27
“Species differentiation of coagulase-negative staphylococci (CNS) was performed using Maldi-TOF [15].”
MethodZhou, M., Yang, Q., Kudinha, T., Zhang, L., Xiao, M., Kong, F., Zhao, Y.-P., & Xu, Y. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.01328 · Cited by 27
Jesumirhewe, C., Ogunlowo, O., Olley, M., Springer, B., Allerberger, F. J., & Ruppitsch, W. (2016) · PeerJ · doi:10.7717/peerj.2511 · Cited by 27
“Reports on the application of MALDI-TOF MS in the clinical microbiology laboratory have been increasing for the past decade (Seng et al., 2009; Bizzini & Greub, 2010; Iroha et al., 2011).”
BackgroundMethodResultEffects of urbanization on host-pathogen interactions, using Yersinia in house sparrows as a model
Rouffaer, L., Strubbe, D., Teyssier, A., Hudin, N. S., den Abeele, A. V., Cox, I., Haesendonck, R., Delmée, M., Haesebrouck, F., Pasmans, F., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0189509 · Cited by 27
Pathogen Identification Direct From Polymicrobial Specimens Using Membrane Glycolipids
Fondrie, W. E., Liang, T., Oyler, B. L., Leung, L. M., Ernst, R. K., Strickland, D. K., & Goodlett, D. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-33681-8 · Cited by 27
Kim, J.-H., Kim, T. S., Jung, H. G., Kang, C. K., Jun, K. I., Han, S., Kim, D. Y., Kwon, S., Song, K., Choe, P. G., et al. (2019) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkz168 · Cited by 29
First characterization of methanogens in oral cavity in Malian patients with oral cavity pathologies
Sogodogo, E., Doumbo, O. K., Aboudharam, G., Kouriba, B., Diawara, O., Koita, H., Togora, S., & Drancourt, M. (2019) · BMC Oral Health · doi:10.1186/s12903-019-0929-8 · Cited by 27
Self-citationA simple method using T4 DNA polymerase to clone polymerase chain reaction products.
Wang, K., Koop, B. F., & Hood, L. (1994) · PubMed · Cited by 27
A Revolution in the Identification of Pathogens in Clinical Laboratories
Nassif, X. (2009) · Clinical Infectious Diseases · doi:10.1086/600886 · Cited by 27
“The article in this issue of Clinical Infectious Diseases by Seng et al [1] describes, for the first time, the use of the first strategy in routine clinical microbiology.”
BackgroundMethodInfluentialQuorum Sensing Activity of Hafnia alvei Isolated from Packed Food
Tan, J.-Y., Yin, W., & Chan, K. (2014) · Sensors · doi:10.3390/s140406788 · Cited by 28
“Bacteria isolated were then identified via a Bruker MALDI Biotyper System (Bruker, Daltonik GmbH, Leipzig, Germany) [10] using the extraction method as provided by the manufacturer.”
MethodCell Extract-Containing Medium for Culture of Intracellular Fastidious Bacteria
Singh, S., Kowalczewska, M., Edouard, S., Eldin, C., Perreal, C., Weber, P., Azza, S., & Raoult, D. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.00719-13 · Cited by 26
Self-citationOccurrence of Carbapenemase-Producing Klebsiella pneumoniae in Bat Guano
Gharout-Sait, A., Touati, A., Ahmim, M., Brasme, L., Guillard, T., Agsous, A., & de Champs, C. (2019) · Microbial Drug Resistance · doi:10.1089/mdr.2018.0471 · Cited by 29
Metadata
- Authors
- Seng, P., Drancourt, M., Gouriet, F., La Scola, B., Fournier, P., Rolain, J. M., & Raoult, D.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Raoult, Didier
- ORCID
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-08-15
- Volume
- 49
- Issue
- 4
- Pages
- 543-551
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2172112723
- Cited by
- 1,983
- References
- 50
- Citations by year
- 2026: 59 · 2025: 51 · 2024: 52 · 2023: 78 · 2022: 98 · 2021: 109 · 2020: 121 · 2019: 158 · 2018: 147 · 2017: 160 · 2016: 173 · 2015: 134 · 2014: 149 · 2013: 153 · 2012: 126
- FWCI
- 72.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Infectious Diseases (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- MALDI-TOF mass spectrometry, bacterial identification, species identification, 16S rRNA gene sequencing, rpoB gene sequencing, identification accuracy, cost-effectiveness, biochemical identification
- MeSH terms
- Bacteria, Bacterial Infections, Bacterial Proteins, Bacteriological Techniques, Diagnostic Errors, Humans, Retrospective Studies, Sensitivity and Specificity, Time Factors, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.